Napoleon Fireplaces Comprehensive Guide to the GDS50 Manual for Replacement Blower Installation

Page 19

19

REPLACEMENT BLOWER INSTALLATION

FIGURE 34

FIGURE 35

RELIEF DOOR GASKET

RELIEF DOOR

TWIN BLOWER

BLOWER

THERMODISC

N

O

T

T

white ground black

VARIABLE

SPEED

SWITCH

O

O

FF

1.Turn off the electrical power and the gas supply to the stove.

2.Open the lower louvre control door, the two side doors, and the fire viewing door. Remove the logs.

3.Remove the relief door assembly held on with 6 screws. Discard the gasket.

4.Disconnect the two blower wires. Remove the blower bracket held on with 4 screws.

5.Replace the blower using the existing bracket. When connecting the replacement blower, tighten the screws with- out distorting the rubber grommets. Replace the bracket/ blower assembly in the unit.

6.Reconnect the two wires. Hold the replacement gasket in place and reattach the relief door assembly. Replace the logs. Close all doors.

7.Turn the gas supply and electricity back on.

Because the blower is thermally activated, when turned on, it will automatically start approximately 15-30 min- utes after lighting the stove and will run for approximately 30-45 minutes after the stove has been turned off. Use of the fan increases the output of heat.

Drywall dust will penetrate into the blower bearings caus- ing irreparable damage and must be prevented from coming into contact with the blower or its compartment. Any damage resulting from this condition is not covered by the warranty policy.

W415-0098 / C / 04.19.06

Image 19
Contents GAS-FIRED Stoves Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Information General InstructionsCare of GLASS, and Plated Parts GDS50 and GS50 Location & ClearancesVenting Lengths AIR Terminal Locations Direct Vent Specifics Model GDS50GAS Stove AIR Terminal Locations Special Installation Example Offset Installation ExampleHorizontal Wall and Ceiling Protection Horizontal Installation Vertical InstallationStove Pipe Must Rise ¼ PER Foot of RUN Vertical Venting Installation Horizontal Venting InstallationStove Vent Connection Mobile Home InstallationAdding Vent Sections Chimney InstallationInstalling B Vent Vent Specifics Model GS50TWO Screws Must be RE-SECURED. Figure Installing Flashing Storm CollarVent Adaptations Combustion AIRVent Model GS50 GAS InstallationGAS Installation Vent Model GS50 only Direct Vent Model GDS50Finishing Door Opening and Closing Trivet InstallationFire Viewing Door Side Door Valve Control Door LOG Placement Operating Instructions Operation / MaintenanceTurbo Burner Operation Maintenance Spill SwitchFor Your Safety Read Before Lighting Replacement Blower Installation Front Burner Rear Burner AdjustmentsPilot Burner Adjustment Venturi AdjustmentGD112 Flat Roof ReplacementsGD175 Wall Terminal KIT GD180 PeriscopeAtte Symptom Problem Test Solution Trouble Shooting GuideModel GDS50 only