GAS INSTALLATION
GAS INSTALLATION |
|
|
Read the section on opening the door in "Finish- ing" prior to proceeding to prevent damaging the unit.
Bring the gas line to the stove through either the opening in the pedestal back or through the floor directly beneath the pedestal base.
Install rigid black pipe or ½" type L copper tubing with a
Seal and tighten the gas line securely to the flex connector supplied.
Do not kink the flexible connector.
Mark the two appropriate boxes on the rating plate la- bel. One to indicate the model type depending on the in- stallation (direct vent or
HOMOLOGUESELONLESNORMESFOYERDECHAUFFAGE | |||||
VENTEDGASFIREPLACEHEATERAPPLIANCEMUSTBE | AU GAZ AVEC EVACUATION CET APPAREIL DOIT ETRE | ||||
INSTALLED USING BURNER KIT : | INSTALLE EN UTILISANT UN ENSEMBLE DU BRULEUR: | ||||
OR |
|
| |||
CDVS500 | GDS50 |
| CDVS500 | ||
|
| ||||
40,000 BTU/h | |||||
44,000 BTU/h | 40,000 BTU/h |
| INPUT/ALIMENTATION | 21,000 BTU/h | 36,000 BTU/h |
20,000 BTU/h | 18,000 BTU/h | REDUCED INPUT / ALIMENTATION REDUITE30,400 BTU/h | 18,000 BTU/h | ||
33,000 BTU/h | 30,000 BTU/h |
| OUTPUT (MODEL GDS50) RENDEMENT 30,000 BTU/h | 27,400 BTU/h | |
31,200 BTU/h | 28,400 BTU/h |
| OUTPUT (MODEL GS50) RENDEMENT | #53 | 26,400 BTU/h |
#34 | #36 |
| FRONT ORIFICE / INJECTEUR AVANT | #57 | #53 |
#43 | #45 |
| TURBO ORIFICE / INJECTEUR TURBO |
| #59 |
|
|
|
|
Attach one lead from the spill switch (white wire) to terminal #3 located on the gas valve and the other (black) on/off switch lead to valve terminal #1.
FIGURE 30
Attach the
ATTACH THIS LABEL IN THE CONTROL AREA OF THE FIREPLACE.
THIS FIREPLACE HAS BEEN CONVERTED TO A ‘B’VENT MODEL.
ATTACHEZ CET ETIQUETTE DANS LA REGION DE CONTROLE DU FOYER.
CE FOYER AETE CONVERTI AUN MODELE ASYSTEME D’EVACUATION ‘B’.
Check for gas leaks by brushing on a soap and water solu- tion. DO NOT USE OPEN FLAME.
DIRECT VENT MODEL GDS50
Disconnect the existing wires from terminals 1 and 3 (from the on/off switch) and replace with the leads from the wall switch/millivolt thermostat.
B-VENT MODEL GS50
*ALTITUDEDOWNRATINGCONDITIONSAPPLYTOCANADA ONLY
LES CONDITIONS DE BAISSE D’EVALUATION SELON L’ALTITUDES’APPLIQUENTAUCANADASEULEMENT MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG) / 10 INCHES W.C.(LP) PRESSION AU COLLECTEUR: 3.5" D'UNE COLONNE D'EAU(GN)
10" D'UNE COLONNE D'EAU (PG)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG) / 11" W.C. (LP)
PRESSIOND'ALIMENTATIONMIN:4.5"D'UNECOLONNED'EAU
11" D'UNE COLONNE D'EAU (PG)
MAX. SUPPLY PRESSURE: 7" W.C. (NG) / 13" W.C. (LP)
PRESSIOND'ALIMENTATIONMAX:7"D'UNECOLONNED'EAU
13" D'UNE COLONNE D'EAU (PG)
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULEMENTAVECCETTEUNITE.
WARNING:DONOTADDANYMATERIALTOTHEAPPLIANCE, WHICHWILLCOMEINCONTACTWITHTHEFLAMES,OTHER THANTHATSUPPLIEDBYTHEMANUFACTURERWITHTHEAP- PLIANCE.
AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR LE FABRICANT.
MINIMUMCLEARANCETOCOMBUSTIBLEMATERIAL/ DEGAGEMENTSMINIMAUXDESMATERIAUXCOMBUSTIBLES:
A | 7" | D 17½" |
B | 2" | E 6¼" |
C | 1" | F 9½" |
20"TOCEILINGFROMSTOVETOP 20"ENTRELEDESSUSDUFOYERETLEPLAFOND ELECTRICAL RATING / CLASS.: 115V 1.5AMP 60HZ
B-VENT MODELS GS50/CS500 APPROVED FOR BED-
ROOM,&BEDSITTINGROOMINSTALLATION. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, & UN STUDIO.
STEADY STATE EFFICIENCY (NG): 71% FAN OFF / 77% FAN ON
STEADY STATE EFFICIENCY (LP): 73% FAN OFF / 78% FAN ON
EFFICACITECONSTANTE(GN):71%VENT.ARRETE 77%VENT.FONCTIONNE
EFFICACITECONSTANTE(GP):73%VENTILATEURARRETE 78% VENTILATEUR FONCTIONNE STEADY STATE EFFICIENCY APPLIES TO CANADA ONLY /
L'EFFICACITE CONSTANTE S'APPLIQUENT SEULEMENT AU CANADA.
AFUE (NG/LP) (GN/GP): 64% / 67%
THISAPPLIANCEMUSTBEINSTALLEDUSINGANADAPTER
NOT FOR USE WITH SOLID FUEL
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE
AVEC CET APPAREIL
DIRECT VENT MODELS GDS50 CDVS500 APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED STATES THE MANUFACTURED HOME CONTRUCTION AND SAFETY STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLI- CABLE USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME INSTALLATIONS, SITES AND COM- MUNITIES, ANSI / NFPA 501A.
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI SON IN- STALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX
STEADY STATE EFFICIENCY (NG):75% FAN OFF / 78% FAN ON
STEADYSTATEEFFICIENCY(LP):76% FAN OFF / 79% FAN ON
EFFICACITE CONSTANTE (GN): 75% VENT. ARRETE
78% VENT. FONCTIONNE
EFFICACITE CONSTANTE (GP): 76% VENTILATEUR ARRETE 79%VENTILATEURFONCTIONNE STEADY STATE EFFICIENCY APPLIES TO CANADA ONLY /
L'EFFICACITE CONSTANTE S'APPLIQUENT SEULEMENT AU CANADA.
AFUE (NG/LP) (GN/GP): 65% / 67%
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 25 INCHES AND 20 FEET RESPECTIVELY. LES LONGUEURS HORIZONTALES MINIMALE ET MAXIMALE SONT 25 POUCES ET 20 PIEDS RESPECTIVEMENT.
THE APPLIANCE MUST BE VENTED USING THE APPROPRI- ATE NAPOLEON VENT KITS. SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLA- TION AND RESEALING IS NECESSARY AFTER SERVICING THE
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION PROPRE A NAPOLEON. REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE POUR L'EVACUATION PRECISE. IL EST IMPORTANT DE BIEN REINSTALLER ET RESCELLER L'EVENT APRES AVOIR AS- SURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.
WOLF STEEL LTD
BARRIE, ONTARIO CANADA
MADE IN CANADA / FABRIQUE AU CANADA
SERIALNUMBER GDS50
NO.DESERIE
Disconnect the existing on/off switch wire from terminal 1 on the valve and the black switch wire from the terminal block. Replace each connection using the wires from the wall switch/millivolt thermostat. FIGURE 30.
FIGURE 29