Napoleon Fireplaces GDS 50-P, GDS 50-N manual Location & Clearances, GDS50 and GS50

Page 5

5

LOCATION & CLEARANCES

Provide adequate ventilation and combustion air.

Provide adequate accessibility clearance for servicing and operating the stove.

Never obstruct the front opening of the stove.

Objects placed in front of the fireplace must be kept a minimum of 48" away from the front face of the unit.

GDS50 AND GS50

As long as clearance to combustibles is kept within the required distances, the most desirable and benefical location for a Napoleon stove is in the centre of a building, thereby allowing the most efficient use of the heat created. The location of windows, doors and the traffic flow in the room where the stove is to be located should be con- sidered. If possible, you should choose a loca- tion where the vent will pass through the house without cutting a floor or roof joist.

 

28¼"

 

FIGURE 1

 

 

 

 

14-1/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16-7/8"

11"

 

WINDOW OPENING

 

 

13-3/4"

 

21"

 

30-3/4"

21-5/8"

4"ø 8"

FLUE

7"ø

AIR INTAKE

GAS LINE LOCATED

IN PEDESTAL REAR

FIGURE 2

W415-0098 / C / 04.19.06

Image 5
Contents GAS-FIRED Stoves Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Care of GLASS, and Plated Parts General InstructionsGeneral Information GDS50 and GS50 Location & ClearancesGAS Stove Direct Vent Specifics Model GDS50Venting Lengths AIR Terminal Locations AIR Terminal Locations Horizontal Offset Installation ExampleSpecial Installation Example Stove Pipe Must Rise ¼ PER Foot of RUN Horizontal Installation Vertical InstallationWall and Ceiling Protection Vertical Venting Installation Horizontal Venting InstallationStove Vent Connection Mobile Home InstallationInstalling B Vent Chimney InstallationVent Specifics Model GS50 Adding Vent SectionsVent Adaptations Installing Flashing Storm CollarCombustion AIR TWO Screws Must be RE-SECURED. FigureGAS Installation Vent Model GS50 only GAS InstallationDirect Vent Model GDS50 Vent Model GS50Fire Viewing Door Side Door Valve Control Door Door Opening and Closing Trivet InstallationFinishing LOG Placement Turbo Burner Operation Maintenance Operation / MaintenanceSpill Switch Operating InstructionsFor Your Safety Read Before Lighting Replacement Blower Installation Pilot Burner Adjustment AdjustmentsVenturi Adjustment Front Burner Rear BurnerGD175 Wall Terminal KIT ReplacementsGD180 Periscope GD112 Flat RoofAtte Symptom Problem Test Solution Trouble Shooting GuideModel GDS50 only