TROUBLE SHOOTING GUIDE
BEFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR OPEN.
SYMPTOM | PROBLEM |
| TEST SOLUTION |
Pilot will not light. | No spark at pilot burner | - | check if pilot can be lit by a match |
|
| - | check that the wire is connected to the push button ignitor. |
|
| - | check if the push button ignitor needs tightening. |
|
| - | replace the wire if the wire insulation is broken or frayed. |
|
| - replace the electrode if the ceramic insulator is cracked or broken. | |
|
| - | replace the push button ignitor. |
Spark gap is incorrect
No gas at the pilot burner
-spark gap should be 0.150" to 0.175" (5/32" to 11/64" approx.) from the electrode tip and the pilot burner. To ensure proper electrode location, tighten securing nut (finger tight plus 1/4 turn).
-check that the manual valve is turned on.
-check the pilot orifice for blockage.
-replace the valve.
-call the gas distributor.
Pilot goes out when the gas knob is re- leased.
Out of propane gas.- fill the tank.
System is not correctly purged. - purge the gas line with the glass door open.
| Out of propane gas | - | fill the tank. | |
|
|
|
| |
Pilot flame is not large enough | - | turn up the pilot flame. |
| |
Pilot flame is not engulfing the | - | turn up pilot flame. | ||
thermocouple. | - | replace pilot assembly. | ||
|
|
|
|
|
| Thermocouple shorting. | - | loosen and tighten thermocouple. | |
|
| - | clean thermocouple and valve connection. | |
|
| - | replace thermocouple. | |
|
| - | replace valve. |
Pilot burning; no gas to main burner; gas knob is on 'HI'; wall switch / thermostat is on.
Faultly thermocouple. | - | replace. | |
Faulty valve. | - | replace. | |
| Main burner orifice is plugged. | - | remove stoppage in orifice. |
|
|
|
|
| Faulty thermopile. | - | replace. |
| Faulty themostat or switch. | - | connect a jumper wire across the wall switch terminals; if |
|
| main burner lights, replace thermostat. | |
|
| - | disconnect the switch wires & connect a jumper wire across |
|
| terminals 1 & 3; if the main burner lights, check the wires for | |
|
| defects and / or replace wires. |
| Faulty valve. | Replace. | ||
|
|
|
| |
Pilot goes out while Gas piping is undersized. | - | turn on all gas appliances and see if pilot flame flutters, | ||
standing; Main burner | diminishes or extinguishes, especially when main burner ig- | |||
is in 'OFF' position. | nites. Monitor supply pressure. | |||
|
| - | check if supply piping size is to code. Correct all undersized | |
|
| piping. | ||
|
|
|
|
|
Main burner goes out; pilot stays on.
Pilot flame is not large enough - | turn up pilot flame. | |
or not engulfing the thermopile. - replace pilot assembly. | ||
Thermopile shorting | - | clean thermopile and thermopile connection to valve. |
Remote wall switch wire is too - shorten wire to correct length or wire gauge. long, too much resistance in
the system
Faulty thermostat or switch | - replace |