INSTALLING FLASHING
AND STORM COLLAR
Remove nails from the shingles above and to the sides of the chimney. Place the flashing over the vent pipe and slide it underneath the sides and upper edge of the shingles. Ensure that the vent pipe is properly centered within the flashing, giving a 3/4" margin all around. Fasten to the roof on the top and sides. DO NOT NAIL through the lower portion of the flashing.
Make
sealing with caulking. Where possible, cover
the sides and top
edges of the flashing with roofing material.
Apply waterproof caulking around the vent, 1" above the top of the flashing and push the
storm collar down into the caulking. Attach a rain cap to the top of the last vent section.
'B' VENT ADAPTATIONS
Read the section on opening the door in "Finish- ing" prior to proceeding to prevent damaging the unit.
1.Remove both burners and the log support bracket.
LOG SUPPORT BRACKET REAR BURNER
FRONT BURNER
FIGURE 26
2.Remove the combustion air cover plate and its gasket.
THE TWO SCREWS MUST BE RE-SECURED. FIGURE 26.
3.Undo the bracket holding the thermodisc, turn 90° as shown and reattach to the weld stud located on the right air manifold side. FIGURE 27. (Do not tighten the wing nut until burner is installed; then ensure that the thermodisc firmly touches the underside of the burner tray and tighten. This enables the blower to function properly.)
13
FIGURE 28
SPILL SWITCH
WIRES
4.Secure the terminal block into place as shown with the screw supplied. FIGURE 28.
5.Gently pull the two white spill switch wires to take up any slack. Feed these wires down through the combustion air opening and back up through the 4x6 inch
6.Attach the black on/off switch wire with the 3/16" tab to the other side of the terminal block. Connect the remaining wires (1 black - 1 white) with ¼" connectors to TP/TH and TH on the gas valve.
7.Replace and
COMBUSTION AIR
ANY STOVE NEEDS AIR FOR SAFE OPERATION AND MUST BE INSTALLED IN SUCH A WAY THAT ADEQUATE COMBUSTION AIR IS AVAILABLE. THIS UNIT IS DE- SIGNED TO FUNCTION USING EITHER OUTSIDE OR IN- SIDE (ROOM) AIR.
If using outside air, connections can be made through a hole in the floor to line up with the hole in the pedestal base. Use a fresh air kit available through your Napoleon Fireplace dealer or Wolf Steel Ltd. Secure the 4" diameter aluminium liner to the hole in the base of the pedestal. Avoid cutting away floor joist, electrical wiring or plumbing. Seal around the outside pipe with insulation to prevent drafts.
TURBO
FIGURE 27VIEWING
MIRROR
COMBUSTION AIR COVER PLATE
Continue with "Gas
Installation" Page 14