FIGURE 25

INSTALLING FLASHING

AND STORM COLLAR

Remove nails from the shingles above and to the sides of the chimney. Place the flashing over the vent pipe and slide it underneath the sides and upper edge of the shingles. Ensure that the vent pipe is properly centered within the flashing, giving a 3/4" margin all around. Fasten to the roof on the top and sides. DO NOT NAIL through the lower portion of the flashing.

Make weather-tight by

sealing with caulking. Where possible, cover

the sides and top

edges of the flashing with roofing material.

Apply waterproof caulking around the vent, 1" above the top of the flashing and push the

storm collar down into the caulking. Attach a rain cap to the top of the last vent section.

'B' VENT ADAPTATIONS

Read the section on opening the door in "Finish- ing" prior to proceeding to prevent damaging the unit.

1.Remove both burners and the log support bracket.

LOG SUPPORT BRACKET REAR BURNER

FRONT BURNER

FIGURE 26

2.Remove the combustion air cover plate and its gasket.

THE TWO SCREWS MUST BE RE-SECURED. FIGURE 26.

3.Undo the bracket holding the thermodisc, turn 90° as shown and reattach to the weld stud located on the right air manifold side. FIGURE 27. (Do not tighten the wing nut until burner is installed; then ensure that the thermodisc firmly touches the underside of the burner tray and tighten. This enables the blower to function properly.)

13

FIGURE 28

SPILL SWITCH

WIRES

4.Secure the terminal block into place as shown with the screw supplied. FIGURE 28.

5.Gently pull the two white spill switch wires to take up any slack. Feed these wires down through the combustion air opening and back up through the 4x6 inch cut-out in the base. Connect the shorter of the 2 wires to the terminal block.

6.Attach the black on/off switch wire with the 3/16" tab to the other side of the terminal block. Connect the remaining wires (1 black - 1 white) with ¼" connectors to TP/TH and TH on the gas valve.

7.Replace and re-secure the log support bracket and the two burners ensuring that each venturi fits over the burner orifice.

COMBUSTION AIR

ANY STOVE NEEDS AIR FOR SAFE OPERATION AND MUST BE INSTALLED IN SUCH A WAY THAT ADEQUATE COMBUSTION AIR IS AVAILABLE. THIS UNIT IS DE- SIGNED TO FUNCTION USING EITHER OUTSIDE OR IN- SIDE (ROOM) AIR.

If using outside air, connections can be made through a hole in the floor to line up with the hole in the pedestal base. Use a fresh air kit available through your Napoleon Fireplace dealer or Wolf Steel Ltd. Secure the 4" diameter aluminium liner to the hole in the base of the pedestal. Avoid cutting away floor joist, electrical wiring or plumbing. Seal around the outside pipe with insulation to prevent drafts.

TURBO

FIGURE 27VIEWING

MIRROR

COMBUSTION AIR COVER PLATE

Continue with "Gas

Installation" Page 14

W415-0098 / C / 04.19.06

Image 13
Contents GAS-FIRED Stoves Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Information General InstructionsCare of GLASS, and Plated Parts GDS50 and GS50 Location & ClearancesVenting Lengths AIR Terminal Locations Direct Vent Specifics Model GDS50GAS Stove AIR Terminal Locations Special Installation Example Offset Installation ExampleHorizontal Wall and Ceiling Protection Horizontal Installation Vertical InstallationStove Pipe Must Rise ¼ PER Foot of RUN Vertical Venting Installation Horizontal Venting InstallationStove Vent Connection Mobile Home InstallationInstalling B Vent Chimney InstallationVent Specifics Model GS50 Adding Vent SectionsVent Adaptations Installing Flashing Storm CollarCombustion AIR TWO Screws Must be RE-SECURED. FigureGAS Installation Vent Model GS50 only GAS InstallationDirect Vent Model GDS50 Vent Model GS50Finishing Door Opening and Closing Trivet InstallationFire Viewing Door Side Door Valve Control Door LOG Placement Turbo Burner Operation Maintenance Operation / MaintenanceSpill Switch Operating InstructionsFor Your Safety Read Before Lighting Replacement Blower Installation Pilot Burner Adjustment AdjustmentsVenturi Adjustment Front Burner Rear BurnerGD175 Wall Terminal KIT ReplacementsGD180 Periscope GD112 Flat RoofAtte Symptom Problem Test Solution Trouble Shooting GuideModel GDS50 only