Napoleon Fireplaces GDS 50-N, GDS 50-P manual For Your Safety Read Before Lighting

Page 18

18

OPERATION / MAINTENANCE

FOR YOUR SAFETY READ BEFORE LIGHTING:

A. This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly.

B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor.

C. Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D. Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control system and any gas control which has been under wa- ter.

WHAT TO DO IF YOU SMELL GAS:

Turn off all gas to the fireplace.

Open windows.

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire de- partment.

GAS KNOB

LIGHTING INSTRUCTIONS

WARNING: The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermocou- ple has cooled. Allow approximately 60 seconds for the thermocouple to cool.

When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed slightly.

1.Stop! Read the above safety information on this label.

2.Turn off all electric power to the fireplace.

3.Turn the gas knob clockwise to off.

4.Wait five (5) minutes to clear out any gas. If you smell gas including near the floor. Stop! Follow "B" in the above safety information on this label. If you don't smell gas go the next step.

5. Turn gas knob counter-clockwise to pilot.

6.Depress slightly and hold gas knob while lighting the pilot with the push button ignitor. Keep knob depressed for one minute, then release. If pilot does not continue to burn, repeat steps 3 through 5.

7.With pilot lit, depress and turn gas knob counter-clock- wise to on.

8.If equipped with remote on-off switch/thermostat, main burner may not come on when you turn valve to on. Remote switch must be in the on position to ignite burner.

9.Turn on all electric power to

the fireplace.

 

OL

 

 

 

 

N

O

 

 

F

 

HI

O

F

 

 

P

 

 

 

 

FLAME

 

TOLI

TOLI

ADJUSTMENTPILOT

P

 

ON/OFF

 

KNOB

 

 

KNOB

TO TURN OFF GAS

1.Turn off all electric power to the fireplace if service is to be performed.

2.Push in gas control knob slightly and turn clockwise to off. Do not force.

MAINTENANCE

TURN OFF THE GAS AND UNPLUG ELECTRI-

CAL POWER BEFORE SERVICING THE

STOVE!

CAUTION: Label all wires prior to disconnection when ser- vicing controls. Wiring errors can cause improper and dan- gerous operation. Verify proper operation after servicing. This stove and its venting system should be inspected before use and at least annually by a qualified service per- son. The fireplace area must be kept clear and free of com- bustible materials, gasoline or other flammable vapours and liquids. The flow of combustion and ventilation air must not be obstructed.

1. In order to properly clean the burner and pilot assem- bly, remove the logs exposing both assemblies.

2. Keep the control compartment, logs, burner, air shut- ter opening and the area surrounding the logs clean by vacuuming or brushing, at least once a year.

3. Check to see that all burner ports are burning. Clean out any of the ports which may not be burning or are not burning properly.

4. Check to see that the pilot flame is large enough to engulf the thermocouple on one leg and reaches toward the burner on the other leg.

5. Replace the cleaned logs.

6. Check to see that the main burner ignites completely on all openings when the gas knob for the burner is turned on. A 5-10 second total light-up period is satisfactory. If ignition takes longer, consult your Napoleon dealer/dis- tributor.

7.Check that the door gasketing is not broken or miss- ing. Replace if necessary.

8.Lift the door from its hinges to clean hinge pins and lubricate using high-temp dry graphite as necessary. Re- place.

NOTE: Due to the high temperatures that the hinges expe- rience, wet lubricants such as oil and WD40 will cause the hinge to seize and are therefore not suitable.

W415-0098 / C / 04.19.06

Image 18
Contents GAS-FIRED Stoves Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Instructions General InformationCare of GLASS, and Plated Parts Location & Clearances GDS50 and GS50Direct Vent Specifics Model GDS50 Venting Lengths AIR Terminal LocationsGAS Stove AIR Terminal Locations Offset Installation Example Special Installation ExampleHorizontal Horizontal Installation Vertical Installation Wall and Ceiling ProtectionStove Pipe Must Rise ¼ PER Foot of RUN Horizontal Venting Installation Vertical Venting InstallationMobile Home Installation Stove Vent ConnectionVent Specifics Model GS50 Chimney InstallationInstalling B Vent Adding Vent SectionsCombustion AIR Installing Flashing Storm CollarVent Adaptations TWO Screws Must be RE-SECURED. FigureDirect Vent Model GDS50 GAS InstallationGAS Installation Vent Model GS50 only Vent Model GS50Door Opening and Closing Trivet Installation FinishingFire Viewing Door Side Door Valve Control Door LOG Placement Spill Switch Operation / MaintenanceTurbo Burner Operation Maintenance Operating InstructionsFor Your Safety Read Before Lighting Replacement Blower Installation Venturi Adjustment AdjustmentsPilot Burner Adjustment Front Burner Rear BurnerGD180 Periscope ReplacementsGD175 Wall Terminal KIT GD112 Flat RoofAtte Trouble Shooting Guide Symptom Problem Test SolutionModel GDS50 only