Monessen Hearth SS38 Air shutter Adjustment Natural Gas only, Adjusting the AIR Shutter

Page 31

air shutter Adjustment (Natural Gas only)

SS38 Direct Vent Gas Stove

ADJUSTING THE AIR SHUTTER

The venturi of the burner is equipped with an air shutter. The opening of the venturi has been set at 1/4" for Natural Gas and fully open for Propane installation at sea level. Natural Gas Models may be adjusted for high altitude as follows:

To increase air mixture, push up the adjustment rod located beneath the stove. This opens the shutter more and will stop or minimize sooting. Figure 46

To decrease air mixture, pull down the adjustment rod located beneath the stove. This closes the shutter. Flames will be more yellow. Figure 47

Air Shutter

ST1114

Adjustment Rod

Figure 46 -

Push Adjustment Rod Up to

Open Air Shutter

Air Shutter

ST1115

Adjustment

Rod

Figure 47 -

Pull Adjustment Rod Down to Close Air Shutter

46D0232

31

Image 31
Contents What to do if YOU Smell GAS StratfordSS38 Direct Vent Gas Stove Table of ContentsInstaller Important Safety InformationOwner Code Approval Important Safety InformationListed Vented GAS Stove Heater Gas Specifications & Orifice Size Product featuresProduct Specifications Installing Above 2000 FeetSS38 Direct Vent Gas Stove Stove Location General Installation InformationFull width and depth of the appliance Clearances to combustiblesFront of the heater Instructions exactly can create a fire hazardFor Horizontal Termination Venting Installation InformationInstallation Precautions Installation PlanningVenting Installation Information Installing a vent system in an Outside chaseCanadian Installations1 US Installations2 47.5 121cm Siding Venting installationInstallation for Horizontal TERMI- Nation Do not recess vent terminal into a wall orVenting Installation Horizontal Venting Vertical V Minimum Horizontal H Maximum Horizontal termination configurationsVenting Installation Installation for Vertical TERMINA- TionCathedral Ceiling Installation Venting Installation Flat Ceiling InstallationVertical Termination CONFIGURA- Tions Vertical Venting with Two 2 Elbows Vertical Venting with Two 2 Elbows Horizontal H + H1Horizontal H + H1 Minimum Stove Installation Install gas piping to stove / burner system locationCheck gas type Propane/LP Stove InstallationCSA-B149 1 or 2 Installation Code Natural GasDo not use open flame to check for gas leaks Installing LouversElectrical Wiring Electrical InstallationRemote Wall mounted Switch Final Installation Installing logs and rock wool ember material in fireboxFinal Installation Install Rock Wool What to do if YOU Smell GAS Operating InstructionsNever use an open flame to check for gas leak Operating Instructions Approved leak testing methodNever check for gas leak with open flame Lighting the burner Main burner switchPilot position Venting system Cleaning glassFirebox Cleaning Cleaning & MaintenanceAdjusting the AIR Shutter Air shutter Adjustment Natural Gas onlyTouch any metal parts during thermal Always use gloves when handlingBroken glass Make sure the glass panel edges do notBlower Blower Wiring diagram for BlowerObserved Problem Possible Cause Remedy TroubleshootingReplacement parts Description Qty Natural Propane SS38DVB,GN,P0Fuel Conversion Kits Description Venting ComponentsCarbon Monoxide Detector Requirements If Warranty Service is Needed Mhsc