VENTING INSTALLATION | SS38 Direct Vent Gas Stove | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
V
H
H1
NOTE: Install restrictor into 4" collar of stove or first vent secton as shown.
Table 6 - Vertical Venting with Two (2) Elbows
Vertical (V) | Horizontal (H) + (H1) |
Minimum | Maximum |
8' | 2' |
9' | 4' |
10' | 6' |
11' | 8' |
23' | 8' |
Figure 24 -
Vertical Rigid Venting Configuration Using Three 90° Elbows with Two Horizontal Runs
H
V1
Table 7 - Vertical Venting with Two (2) 90° |
|
| ||
Elbows |
|
|
| |
Vertical (V) + (V1) | Horizontal (H) + (H1) |
|
| |
V | ||||
Minimum | Maximum | |||
|
| |||
8' | 2' |
|
| |
9' | 12' |
|
| |
10' | 18' |
|
| |
11' | 20' |
|
|
Vertical Venting V = 40' maximum
NOTE: Install restrictor into 4" collar of stove or first vent secton as shown.
V
NOTE: Install restrictor into 4" collar of stove or first vent secton as shown.
| ST1112 |
Figure 25 - | Figure 26 - |
Vertical Rigid Venting Configuration Using | Vertical Rigid Venting Configuration |
Two 90° Elbows | with No Horizontal run |
46D0232 | 19 |