OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

 

Spark ignitor will not light the

1.

Battery needs replacing

1.

Replace battery

 

pilot after repeated pressing of

2.

Defective ignitor

2.

Check connections to ignitor. Replace

 

spark ignitor.

 

 

 

ignitor if ignitor connections are good,

 

 

 

 

 

but there is no spark.

 

 

3.

Misaligned spark electrode

3.

Check for spark arcing from the

 

 

 

 

 

electrode to pilot. Adjust by loosen-

 

 

 

 

 

ing screws on pilot base. Adjust and

 

 

 

 

 

retighten.

 

 

4.

Bad wire.

4.

Replace with new wire.

 

 

 

 

 

 

 

Pilot will not stay lit.

1.

Defective thermocouple.

1.

A. Check for proper connection of

 

 

 

Loose thermocouple

 

thermocouple to rear of valve.

 

 

 

 

 

B. Check thermocouple output.

 

 

2.

Air in gas line

2.

Bleed line. Contact dealer

 

 

3.

No gas

3.

Check shutoff valve and gas supply

 

 

 

 

 

(LPG tank)

 

 

 

 

 

 

Burner will not light when valve

1. Defective switch

1.

Check switch connections. Jump

 

and burner switch are both on.

 

 

 

wires at switch.

 

 

2.

Defective thermopile

2.

A. Check thermopile output.

 

 

 

 

 

B. Check connections to valve. Con-

 

 

 

 

 

tact dealer.

 

 

3.

Thermostat set too low/defective

3.

Turn up thermostat to start unit.

 

 

 

 

 

Check thermostat connections.

 

 

 

 

 

 

Glass fogs up

1. Normal condition

1.

Allow appliance to warm up. Glass

 

 

 

 

 

will clear. Additives in the gas may

 

 

 

 

 

dirty glass. Clean glass when cool.

 

 

 

 

 

 

Blue flames

1. Normal during start up

1.

Flames will yellow as appliance

 

 

 

 

 

heats up.

 

 

 

 

 

 

Sooting

1. Flame impingement

1.

Check log position. Open shutters to

 

 

 

 

 

increase primary air.

 

34

46D0232

Image 34
Contents Stratford What to do if YOU Smell GASTable of Contents SS38 Direct Vent Gas StoveInstaller Important Safety InformationOwner Code Approval Important Safety InformationListed Vented GAS Stove Heater Installing Above 2000 Feet Product featuresProduct Specifications Gas Specifications & Orifice SizeSS38 Direct Vent Gas Stove General Installation Information Stove LocationInstructions exactly can create a fire hazard Clearances to combustiblesFront of the heater Full width and depth of the applianceInstallation Planning Venting Installation InformationInstallation Precautions For Horizontal TerminationInstalling a vent system in an Outside chase Venting Installation InformationCanadian Installations1 US Installations2 47.5 121cm Do not recess vent terminal into a wall or Venting installationInstallation for Horizontal TERMI- Nation SidingVenting Installation Horizontal termination configurations Horizontal Venting Vertical V Minimum Horizontal H MaximumInstallation for Vertical TERMINA- Tion Venting InstallationVenting Installation Flat Ceiling Installation Cathedral Ceiling InstallationVertical Termination CONFIGURA- Tions Vertical Venting with Two 2 Elbows Vertical Venting with Two 2 Elbows Horizontal H + H1Horizontal H + H1 Minimum Stove Installation Install gas piping to stove / burner system locationCheck gas type Natural Gas Stove InstallationCSA-B149 1 or 2 Installation Code Propane/LPInstalling Louvers Do not use open flame to check for gas leaksElectrical Wiring Electrical InstallationRemote Wall mounted Switch Installing logs and rock wool ember material in firebox Final InstallationFinal Installation Install Rock Wool What to do if YOU Smell GAS Operating InstructionsNever use an open flame to check for gas leak Operating Instructions Approved leak testing methodNever check for gas leak with open flame Lighting the burner Main burner switchPilot position Cleaning & Maintenance Cleaning glassFirebox Cleaning Venting systemAir shutter Adjustment Natural Gas only Adjusting the AIR ShutterMake sure the glass panel edges do not Always use gloves when handlingBroken glass Touch any metal parts during thermalBlower Wiring diagram for Blower BlowerTroubleshooting Observed Problem Possible Cause RemedyReplacement parts Description Qty Natural Propane SS38DVB,GN,P0Fuel Conversion Kits Venting Components DescriptionCarbon Monoxide Detector Requirements If Warranty Service is Needed Mhsc