VENTING INSTALLATION INFORMATION | SS38 Direct Vent Gas Stove |
WARNING
Read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life.
INSTALLATION PRECAUTIONS
Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system for installation. Before installing vent kit, the installer must read this stove manual and vent kit instructions.
Only a qualified installer/service person should install vent- ing system. The installer must follow these safety rules:
•Wear gloves and safety glasses for protection.
•Use extreme caution when using ladders or when on rooftops.
•Be aware of electrical wiring locations in walls and ceilings.
The following actions will void the warranty on your vent- ing system:
•Installation of any damaged venting component.
•Unauthorized modification of the venting system.
•Installation of any component part not manufactured or approved by MHSC.
•Installation other than permitted by these instruc- tions.
| NOTICE | Failure to follow these instructions will |
|
| |
|
| void the warranty. |
|
|
|
|
|
|
| WARNING | This stove must be vented to the outside. |
| The venting system must NEVER be | |
|
| |
|
| attached to a chimney serving a separate |
|
| solid fuel burning appliance. Each gas |
|
| appliance must use a separate vent system. |
|
| Do not use common vent systems. |
|
|
|
|
|
|
|
| Horizontal sections of this vent system |
|
| require a minimum clearance of 2" from |
| WARNING | the top of the pipe and 1" minimum to the |
| sides and bottom. Vertical sections of this | |
|
| |
|
| system require a minimum of 1" clearance |
|
| to combustible materials on all sides of the |
|
| pipe. Only a 1" clearance is required where |
|
| the vent passes through the nearest vertical |
|
| wall. |
INSTALLATION PLANNING
There are two basic types of
•Horizontal Termination
•Vertical Termination
It is important to select the proper length of vent pipe for the type of termination you choose. It is also important to note the wall thickness.
FOR HORIZONTAL TERMINATION
Select the amount of vertical rise desired. The horizontal run of venting must have 1/4" rise for every 12" of run towards the termination.
You may use up to three 90° elbows in this vent configu- ration. Refer to Horizontal Termination Configurations on Page 13.
| WARNING | Never run the vent pipe level or downward. |
|
| |
|
| This may cause excessive temperatures |
|
| which could cause a fire. |
|
|
|
For vertical termination
Measure the distance from the stove flue outlet to the ceil- ing. Add the ceiling thickness, the vertical rise in an attic or second story, and allow for sufficient vent height above the roof line. You may use one or two 90° elbows in this vent configuration. Refer to Vertical Termination Configurations on Page 16.
NOTE: You may use two 45° elbows in place of a 90° elbow. You must follow rise to run ratios when using 45° elbows. The appliance is approved for use with three 90° elbows maximum or a combination of 90° and 45° elbows up to a maximum of 270°.
For
You may use a chase with a vent termination with exposed pipe on the exterior of the house. Refer to Installing Vent System in a Chase.
It is very important that the venting system maintain its bal- ance between the combustion air intake and the flue gas exhaust. Certain limitations apply to vent configurations and must be strictly followed.