Monessen Hearth SS38 Electrical Installation, Electrical Wiring, Remote Wall mounted Switch

Page 23

ELECTRICAL INSTALLATION

SS38 Direct Vent Gas Stove

Electrical Wiring

This stove will work without any electrical supply. Electricity is only needed to operate blower.

NOTE: If installed in mobile home, stove must be bolted securely to floor.

WARNING

Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical power supply or performing service. All wiring shall be in compliance with all local, city and state codes. The appliance, when installed, must be electrically grounded in accordance with local codes or in the absence of local codes, with the National Electrical Code ANSI/NFPA 70 (latest edition) and Canadian Electrical Code, CSA C22.1.

 

CAUTION

Label all wires before disconnecting when

 

 

 

 

servicing controls. Wiring errors can cause

 

 

improper and dangerous operation.

 

 

 

 

 

Verify proper operation after servicing.

Remote Wall mounted Switch

A remote wall switch and up to fifteen (15) feet of 18 Ga. wire may be used with this appliance. Attach the wall switch in a junction box at the desired location on the wall. Figure 31. Do not extend beyond the wall switch wire length provided.

NOTE: Extended lengths of wire may cause the stove not to function properly. Longer length of wire is permitted if the wire is made out of larger gauge (diameter) wire. Always check with local code.

OFF

PILOT

 

HI

 

ON

TH

 

 

 

 

TP

 

 

TH/TP

 

 

 

OPTIONAL REMOTE

 

 

 

WALL SWITCH

 

 

 

ON

ON

OFF

RS

OFF

 

 

 

 

 

 

 

 

OPTIONAL REMOTE

 

 

 

WALL SWITCH

 

 

 

ON

 

 

 

OFF

Figure 31 -

Wiring Diagram for Wall Switch

46D0232

23

Image 23
Contents What to do if YOU Smell GAS StratfordSS38 Direct Vent Gas Stove Table of ContentsOwner Important Safety InformationInstaller Listed Vented GAS Stove Heater Important Safety InformationCode Approval Gas Specifications & Orifice Size Product featuresProduct Specifications Installing Above 2000 FeetSS38 Direct Vent Gas Stove Stove Location General Installation InformationFull width and depth of the appliance Clearances to combustiblesFront of the heater Instructions exactly can create a fire hazardFor Horizontal Termination Venting Installation InformationInstallation Precautions Installation PlanningVenting Installation Information Installing a vent system in an Outside chaseCanadian Installations1 US Installations2 47.5 121cm Siding Venting installationInstallation for Horizontal TERMI- Nation Do not recess vent terminal into a wall orVenting Installation Horizontal Venting Vertical V Minimum Horizontal H Maximum Horizontal termination configurationsVenting Installation Installation for Vertical TERMINA- TionCathedral Ceiling Installation Venting Installation Flat Ceiling InstallationVertical Termination CONFIGURA- Tions Horizontal H + H1 Minimum Vertical Venting with Two 2 Elbows Horizontal H + H1Vertical Venting with Two 2 Elbows Check gas type Install gas piping to stove / burner system locationStove Installation Propane/LP Stove InstallationCSA-B149 1 or 2 Installation Code Natural GasDo not use open flame to check for gas leaks Installing LouversRemote Wall mounted Switch Electrical InstallationElectrical Wiring Final Installation Installing logs and rock wool ember material in fireboxFinal Installation Install Rock Wool Never use an open flame to check for gas leak Operating InstructionsWhat to do if YOU Smell GAS Never check for gas leak with open flame Approved leak testing methodOperating Instructions Pilot position Main burner switchLighting the burner Venting system Cleaning glassFirebox Cleaning Cleaning & MaintenanceAdjusting the AIR Shutter Air shutter Adjustment Natural Gas onlyTouch any metal parts during thermal Always use gloves when handlingBroken glass Make sure the glass panel edges do notBlower Blower Wiring diagram for BlowerObserved Problem Possible Cause Remedy TroubleshootingReplacement parts Fuel Conversion Kits SS38DVB,GN,P0Description Qty Natural Propane Description Venting ComponentsCarbon Monoxide Detector Requirements If Warranty Service is Needed Mhsc