Napoleon Fireplaces GVF40P, GVF40N Glowing Embers, Charcoal Embers, Hood, Mantle Installation

Page 14

14

GLOWING EMBERS

Tear the embers into small pieces and place on the ported area of the burner. Care should be taken to shred the embers into thin, small irregular pieces as only the ex- posed edges of the fibre hairs will glow. The ember mate- rial will only glow when exposed to direct flame; however, care should be taken to not block the burner ports. Blocked burner ports can cause an incorrect flame pattern, carbon deposits and delayed ignition. PHAZERTM logs glow when exposed to direct flame.

CHARCOAL EMBERS

Randomly place the embers around the bottom brick pan- els in a realistic manner but not in contact with the flames. Keep ember dust away from burner ports to avoid plugging them.

Fine dust found in bottom of bag not to be used. PHAZERTM logs, and embers glow when exposed to direct flame. Use only certified PHAZERTM logs, glowing embers and char- coal embers available from your Napoleon / Wolf Steel Ltd. dealer.

GLOWING EMBERS

Dashed lines are suitable mantle sizes and clear- ances when a non-combus- tible facing is used.

FIGURE 25

HOOD

FIGURE 26

HOOD

CURTAIN

MESH

The curtain mesh must be kept fully closed during opera- tion to help prevent accidental burns from occurring.

22

CURTAIN SUPPORT

PLATE

HOOD

FIGURE 27

The heater must not be used when the hood is re- moved. Hook the

hood over the lip of the curtain support plate.

Ensure that glowing embers sufficiently cover the carry over ports, highlighted below, to achieve maximum glow.

CARRY OVER PORTS

FIGURE 23

MANTLE INSTALLATION

Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clear- ance needed. The four-sided top extension piece may be removed if non-combustible framing is faced with a non- combustible material.

FIGURE 24

UPPER LOUVRE BRACKETS & HOOD

FIGURE 28

Attach the hood with louvre brackets by pressing the top flange of the bracket into the clips along the top of the louvre opening with louvre securing tabs facing out.

W415-0319 / D / 08.03.05

Image 14
Contents Unvented Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Carbon Monoxide Poisoning MAY Lead to Death General InstructionsGeneral Information Determining Confined or Unconfined Space InstallationCombustion and Ventilation AIR Provisions GAS Installation Sided Framing Peninsula Installation ProcedureCountertop / BAR Installation Finishing Brick Panel InstallationFacing OPEN-END Installation Procedure = 25¼ minus finishing material thickness each sideSEE-THROUGH Installation Procedure Framing FacingIsland Installation Procedure LOG Placement FinishingCharcoal Embers Mantle InstallationGlowing Embers HoodLogo Placement Gvfl InstallationL36 Louvre Installation Heat Shield STAND-OFF RemovalDoor Opening and Closing GVF103-KT Patented Catalytic Door InstallationOptions Optional Blower Installation This Blower is not Recommended for the 4 Sided InstallationOperation / Maintenance For Your Safety Read Before LightingOxygen Depletion Sensor Pilot Cleaning MaintenanceCatalytic Tile Maintenance Venturi AdjustmentReplacements AccessoriesW415-0319 / D Trouble Shooting Guide Symptom Problem Test SolutionDo not Clean Glass When HOT Fireplace Service History