OPTIONAL BLOWER INSTALLATION

THIS BLOWER IS NOT RECOMMENDED FOR THE 4 SIDED INSTALLATION.

INSTALLATION TO BE DONE BY A QUALIFIED IN- STALLER and must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current ANSI/NFPA 70 NATIONAL ELEC- TRICAL CODE in the United States.

THERMODISC WIRES TO BLOWER

THERMODISC BRACKET

Remove the blower from its mounting bracket and attach to the bracket supplied with the fireplace. This bracket is found secured on the mounting stud located at the bot- tom of the vent side wall.

b l

a

c

k

d re

white

FIGURE 37

FIGURE 41

Remove the thermodisc bracket from the top of the firebox.

Remove the thermodisc from the bracket supplied in the blower kit and install the thermodisc into the fireplace bracket. Then replace the bracket in the location it was removed.

Connect the two ends of the unattached wires by the bracket to the thermodisc.

Connect the opposite ends of the wires to the red and black leads of the blower harness.

FIGURE 38

FIGURE 39

The wire harness provided in this kit is a universal har- ness. When installed, ensure that any excess wire is contained, preventing it from making contact with mov- ing or hot objects.

Drywall dust will penetrate into the blower bearings, caus- ing irreparable damage. Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this condi- tion is not covered by the warranty policy.

The blower bracket contains two holes that allow the blower to be positioned away from the intended gas supply hole.

Position the vibration reducing pad, centred, onto the threaded stud, piercing a hole into the pad. The blower must be able to be positioned entirely onto the pad.

Tilt the blower onto its side and slide it past the controls. Position the blower under the clip and onto the stud. Se- cure with a wing nut.

Because the blower is thermally activated, when turned on, it will automatically start approximately 10 minutes after lighting the fireplace and will run for approximately 30 - 45 minutes after the fireplace has been turned off. Use of the fan increases the output of heat.

FIGURE 40

W415-0319 / D / 08.03.05

Image 17
Contents Unvented Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Carbon Monoxide Poisoning MAY Lead to Death General InstructionsGeneral Information Determining Confined or Unconfined Space InstallationCombustion and Ventilation AIR Provisions GAS Installation Sided Framing Peninsula Installation ProcedureCountertop / BAR Installation Finishing Brick Panel InstallationFacing = 25¼ minus finishing material thickness each side OPEN-END Installation ProcedureFraming Facing SEE-THROUGH Installation ProcedureIsland Installation Procedure Finishing LOG PlacementGlowing Embers Mantle InstallationCharcoal Embers HoodL36 Louvre Installation Gvfl InstallationLogo Placement Heat Shield STAND-OFF RemovalDoor Opening and Closing GVF103-KT Patented Catalytic Door InstallationOptions This Blower is not Recommended for the 4 Sided Installation Optional Blower InstallationFor Your Safety Read Before Lighting Operation / MaintenanceCatalytic Tile Maintenance MaintenanceOxygen Depletion Sensor Pilot Cleaning Venturi AdjustmentAccessories ReplacementsW415-0319 / D Symptom Problem Test Solution Trouble Shooting GuideDo not Clean Glass When HOT Fireplace Service History