23
SYMPTOM | PROBLEM | TEST SOLUTION |
|
|
|
|
|
|
Pilot | goes | out | Gas piping is undersized. | |||
while | standing; |
|
|
| ||
Main burner is in |
|
|
| |||
'OFF' position. |
|
|
| |||
Flames | are | con- | Unit is | |||
sistently too large | fired. |
|
| |||
or too | small. |
|
|
| ||
Carboning occurs. |
| B | A | |||
|
|
|
| OL |
|
|
|
|
|
|
| N | O |
|
|
|
|
| F | |
|
|
|
| HI | O | F |
|
|
|
|
|
| |
|
|
|
|
|
| P |
|
|
|
|
|
| TOLI |
|
|
| P |
|
|
|
|
| TOLI |
|
|
|
Carbon is being Air shutter has become deposited on logs blocked
or combustion
chamber surfaces. Flame is impinging on the logs or combustion cham-
| ber. |
White / grey film | Sulphur from fuel is being |
forms on the glass | deposited on glass, logs or |
of the optional cata- | combustion chamber sur- |
lytic door. | faces. |
Exhaust fumes | Not enough combustion air. |
| |
smelled in room, |
|
headaches. | Not enough ventilation air. |
| |
| Catalytic tile is masked (con- |
| taminated by dust, paint |
| fumes). |
| Flame is impinging on the |
| logs or combustion cham- |
| ber. |
- turn on all gas appliances and see if pilot flame flutters, dimin- ishes or extinguishes, especially when main burner ignites. Monitor appliance supply working pressure.
-check if supply piping size is to code. Correct all undersized piping.
-check pressure readings:
Inlet pressure can be checked by turning screw (A)
Outlet pressure can be checked the same as above using screw
(B). Check with burner operating on "HI". Gauge should read 3.5" water column for natural gas or 10" water column for propane.
AFTER TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DO NOT OVERTORQUE.
Leak test with a soap and water solution.
-ensure air shutter opening is free of lint or other obstructions.
-check that the logs are correctly positioned.
-open air shutter to increase the primary air. See air shutter open- ings, page 13.
-check the input rate: check the manifold pressure and orifice size as specified by the rating plate values.
-clean the glass with a recommended gas fireplace glass cleaner.
DO NOT CLEAN GLASS WHEN HOT.
If deposits are not cleaned off regularly, the glass may become permanently marked.
- increase fresh air supply. (Use one of the methods described in | |
ANSI Z223.1 Section 5.3 or the applicable local code.) | |
- increase fresh air supply. (Use one of the methods described in | |
ANSI Z223.1 Section 5.3 or the applicable local code.) | |
- check CO output from catalytic tiles. See Maintenance Section. | |
Replace if necessary. | |
- | check that the logs are correctly positioned. |
- | open air shutter to increase the primary air. See air shutter open- |
ings, page 13. | |
- | check the input rate: check the manifold pressure and orifice size |
as specified by the rating plate values. |
Remote wall switch is in "OFF" position; main burner comes on when gas knob is turned to "ON" po- sition.
Wall switch is mounted up- side down
Remote wall switch is grounding.
Remote wall switch wire is grounding.
Faulty valve.
- reverse. |
- replace. |
- check for ground (short); repair ground or replace wire. |
- replace. |