Napoleon Fireplaces GVF40P, GVF40N Operation / Maintenance, For Your Safety Read Before Lighting

Page 18

18

OPERATION / MAINTENANCE

If heater shuts off, do not relight until you provide fresh air. If heater keeps shutting off, have it serv- iced. Keep burner and control compartment clean.

When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condi- tion caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again.

After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles burning off. In both cases, open a window to suf- ficiently ventilate the room.

Purge the gas line with the glass door open. Assure that a continuous gas flow is at the burner before clos- ing the door.

FOR YOUR SAFETY READ BEFORE LIGHTING:

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLO- SION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A. This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly.

B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor.

C. Use only your hand to push in and turn the gas control knob. Never use tools. If the knob will not push in and turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may re- sult in a fire or explosion.

D. Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and replace any part of the control system and any gas control which has been under water.

 

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

 

 

 

Do not touch any electric switch; do not use any phone

 

in your building.

 

 

 

Immediately call your gas supplier from a neighbour's

 

phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire de-

 

partment.

 

LO

T

 

 

 

 

 

I

 

 

P

 

 

 

 

F

 

O

 

 

 

N

 

 

F

 

 

 

O

 

 

 

OXYGEN DEPLETION SENSOR

GAS KNOB

LIGHTING INSTRUCTIONS

When lighting and re-lighting, the gas knob cannot be turned from pilot to off unless the knob is depressed.

1.STOP! Read the above safety information on this la- bel.

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the fireplace.

4.Open the control door. Turn the gas knob clockwise

to off.

5.Wait five (5) minutes to clear out any gas. If you smell gas including near the floor, STOP! Follow "B" in the above safety information on this label. If you don't smell gas go to the next step.

6.Find pilot located in front of the back log.

7.Turn gas knob counter-clockwise to pilot.

8.Depress and hold gas knob while lighting the pilot

with the push button igniter. Keep knob fully depressed for one minute, then release. If pilot does not continue to burn repeat steps 3 through 7.

9. With pilot lit, turn gas knob counter-clockwise to on. When the pilot has been turned off, ignition of the main burner may be delayed from 1-2 minutes.

When the pilot has been left burning, ignition of the main burner should occur almost immediatley.

10.If equipped with remote on-off switch, main burner may not come on when you turn the valve to on. Re- mote switch must be in the on position to ignite burner.

11.Turn on all electric power to the fireplace.

GAS KNOB AT OFF

OL

 

N

O

HI

O

F

 

 

P

 

 

TOLI

TOLIP

TO TURN OFF GAS

1. Turn off all electric power to the fireplace if service is to

2. Push in gas control knob slightly and turn clock-

be performed.

wise

to off. Do not force.

W415-0319 / D / 08.03.05

Image 18
Contents Unvented Millivolt System Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Instructions General InformationCarbon Monoxide Poisoning MAY Lead to Death Installation Combustion and Ventilation AIR ProvisionsDetermining Confined or Unconfined Space GAS Installation Sided Peninsula Installation Procedure Countertop / BAR InstallationFraming Brick Panel Installation FacingFinishing OPEN-END Installation Procedure = 25¼ minus finishing material thickness each sideSEE-THROUGH Installation Procedure Framing FacingIsland Installation Procedure LOG Placement FinishingCharcoal Embers Mantle InstallationGlowing Embers HoodLogo Placement Gvfl InstallationL36 Louvre Installation Heat Shield STAND-OFF RemovalGVF103-KT Patented Catalytic Door Installation OptionsDoor Opening and Closing Optional Blower Installation This Blower is not Recommended for the 4 Sided InstallationOperation / Maintenance For Your Safety Read Before LightingOxygen Depletion Sensor Pilot Cleaning MaintenanceCatalytic Tile Maintenance Venturi AdjustmentReplacements AccessoriesW415-0319 / D Trouble Shooting Guide Symptom Problem Test SolutionDo not Clean Glass When HOT Fireplace Service History