Vermont Casting SDDVT Supporting DIRECT-TEMP Vertical Support, Offsets, Adjustable Length AJ

Page 22

Stardance Direct Vent/Natural Vent Gas Heater

Supporting DIRECT-TEMP: Vertical Support

Vertical installations can be supported by two methods:

Ceiling Support (CS) (used in flat ceiling installation) comes with a support plate and a support collar. Install it by screwing the support plate to the top of the prop- erly framed ceiling joist opening, using screws provided. A round trim plate (TP) is attached to the ceiling, using screws, to provide a finished appearance once in- stalled. (Fig. 35)

Offsets:

If any offsets are necessary in the vertical system, an Offset Support (OS) should be installed directly above the upper elbow of the offset. Install by attaching the offset support band to the pipe with two #8 x 1/4” sheet metal screws (minimum ) and secure the offset support straps to surrounding structure. (Fig. 37)

Nail to top of

framing

Ceiling Support Plate

ST923

Ceiling Support Collar

Trim Plate

Offset Support

Offset Support

Strap

Collar

ST927

Fig. 37 Offset support.

Fig. 35 Ceiling support.

The Cathedral Ceiling Support (CCS) may be used in pitched or flat ceiling installations and comes with a support collar and a decorative two part square trim plate. Install by inserting the support box down through the framed joist opening (end with round hole first) in the ceiling using tin snips, cut the corners of the open end of the box such that the sides can be folded down over the top of the joist framing members. Nail the folded sides to the top of the framing. (Fig. 36)

Two Part Square

Trim Plate

Support Box

Support Box Collar

ST926

Fig. 36 Support box.

A two-part square trim plate is provided to give a fin- ished look once installed. Simply fit the two halves of the trim plate around the cathedral ceiling support box hanging below the ceiling (overlapping if necessary) and screw them to the ceiling. Both the ceiling support and cathedral ceiling support can support a maximum of 40’ (12 m) of pipe.

Supporting DIRECT-TEMP: Horizontal Support

Horizontal runs of Direct-Temp should be supported every 4’ (122 cm) of pipe. This can be done with the use of plumbers strapping or the offset support.

Adjustable Length (AJ)

An Adjustable Length is available to accommodate installations where non-standard lengths are necessary. The adjustable length telescopes down over a standard length of pipe and provides an extension range of 3¹⁄” (89 mm) to 10¹⁄” (267 mm). Install by sliding the inlet end of the adjustable length over the outlet end of a standard length of pipe. After positioning the adjustable length appropriately, secure it to the standard length with two (2) #8 x1/4” sheet metal screws (provided). Seal the area between both the top and bottom of the adjustable length outer wall and the outer wall of the standard length with an approved silicone sealant.

Fire Stopping

DIRECT-TEMP must be firestopped wherever it passes through floors, ceiling or walls. The only location where a firestop is not required is at the roof level. Both verti- cal support components with trim plates provide for firestopping. The wall thimble also acts as a firestop. at other locations, a firestop spacer (FS) should be in- stalled. In the attic the firestop should be placed on top of the joist framing to prevent debris from falling into the joist framing. (Fig. 38)

Horizontal Installation

1.Determine the appliance location. Refer to the appli- ance manufacturer’s installation instructions for clear- ance to combustible requirements, termination options, number of elbows, maximum length, etc. Then posi- tion the appliance and plan vent routing accordingly.

22

20012734

Image 22
Contents Stardance Direct Vent/Natural Vent Gas Heater Table of Contents General Information Installation Requirements Gas Equipment Venting System not ProvidedStardance Direct Vent / Natural Vent Dimensions Stardance dimensionsMaterials Clearance RequirementsMinimum Clearances to Combustible Locating the StoveHearth Requirements Wall Centerline from FloorWall and Ceiling Clearances Direct Vent OnlyHigh Elevations Gas SpecificationsGas Inlet and Manifold Pressures Horizontal Termination Direct Vent onlyRestrictor Plate is used on Direct Vent Installations Only Restrictor Plate Adjustment For Extended Pipe RunsRestrictor Plate Adjustment Examples for Extended Run/Restrictor Plate SettingsLocation of Vent Termination Vent Termination ClearancesDirect Vent Only Canadian Installations1 US Installations2 General Venting Information Termination LocationVenting Requirements Natural Vent Only Termination ClearancesSimpson DuraVent Components Venting Requirements and Options Direct Vent onlyApproved Vent System Components Minimum Horizontal Vent Kit 2792CFM Vent Components Install the Optional Fan Remove rear skirt insertInstall the Vent Adapter Pipe Venting System Assemlby Direct Vent General InformationSide Wall Termination Assembly Install Vent Adapter PipeSelkirk Corporation Vent Components Assemble the wall sleeve and firestop Vertical Through the Roof Vent Assembly Vent Termination Below GradeSelkirk Direct-Temp Metalbestos Direct Vent System Inlet End Outlet End To Termination Vertical VentingHorizontal Venting To ApplianceOffsets Adjustable Length AJSupporting DIRECT-TEMP Vertical Support Supporting DIRECT-TEMP Horizontal SupportBelow grade installation Vertical Installation Fig Venting System Assembly Natural Vent General Information Minimum Height Above Roof RequirementsInstall the Vent Pipe Install the Log SetStardance Direct Vent/Natural Vent Gas Heater Connect the Gas Supply Line Install ON/OFF SwitchBurner Information Thermostat Connection optional Install the Front PlateOperation Your First FireSddvt Series Flame & Temperature AdjustmentFlame Characteristics Sddvtc Series Comfort Control ModelsEuro SIT Lighting and Operating InstructionsTo Turn Off Gas To Heater HoneywellTroubleshooting the Gas Control System Sddvt Series SIT Nova 820 Millivolt ValveOn Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Delay Timer ModeChange Between F/C Temperature Units Auto ModeFan Override During Auto Mode Disable Thermostat FunctionLocal Path On PathAuto Path Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Valve Conversion Sddvt Series ModelsPilot Type Pilot Orifice ConversionValve All Models Burner Orifice ConversionBottom View Conversion to LP Input BTU/h Injector Orifice Size MatrixConversion to Natural Gas Input BTU/h Cleaning the Glass MaintenanceLogset and Burner Cleaning and Inspection Glass ReplacementInspect the Vent System Annually Gasket ReplacementStove Disassembly Check the Gas Flame RegularlyOptional Thermostat Wiring Wiring DiagramsOn/Off Switch Wiring Schematic DiagramStardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater DescriptionFuel Conversion Kits Optional Accessories Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Limited Lifetime Warranty CFM Corporation

SDDVT specifications

Vermont Casting's SDDVT, or the Signature Series Direct Vent Technology, represents a remarkable blend of design, efficiency, and functionality in the world of high-performance heating appliances. Known for its commitment to craftsmanship, Vermont Casting has long been synonymous with quality, and the SDDVT is no exception.

One of the standout features of the SDDVT is its advanced direct venting capability. This system allows for efficient venting of combustion gases directly outside, minimizing the risk of backdrafting and ensuring optimal indoor air quality. It draws air from the outside for combustion, creating a more controlled environment that enhances both efficiency and safety. Homeowners can rest easy knowing that the SDDVT provides a reliable heating solution while protecting indoor air quality.

Another significant aspect of the SDDVT is its high-efficiency performance. With an impressive Annual Fuel Utilization Efficiency (AFUE) rating, the SDDVT maximizes heat output while minimizing fuel consumption. This efficiency translates to lower energy bills and a reduced carbon footprint, making it an environmentally friendly choice for heating. The unit is designed to operate effectively even in extremely cold temperatures, ensuring comfort throughout the winter months.

The SDDVT also boasts an array of customizable options that appeal to a wide range of aesthetic preferences. Available in various finishes and styles, including traditional cast iron and sleek modern designs, homeowners can select a model that complements their decor. The unit features a large viewing glass that provides an unobstructed view of the flames, creating a cozy ambiance that enhances the living space.

Incorporating cutting-edge technology, the SDDVT includes electronic ignition and advanced control systems, allowing users to easily manage their heating preferences. The integration of smart technology enables compatibility with home automation systems, giving users added convenience and control.

Overall, Vermont Casting's SDDVT is an exemplary heating solution characterized by its innovative direct venting technology, high efficiency, and customizable design options. With a focus on quality and performance, this unit exemplifies the brand's dedication to providing sustainable and effective heating solutions tailored to modern living. Whether for new construction or retrofitting existing spaces, the SDDVT stands as a premier choice for comfort and style.