Vermont Casting SDDVT manual Operation, Thermostat Connection optional, Install the Front Plate

Page 29
Maximum Run
20 feet
20 - 40 feet up to 60 feet

Stardance Direct Vent/Natural Vent Gas Heater

Thermostat Connection (optional)

Use only a thermostat rated for 500 millivolts.

Check the table below for the appropriate gauge ther- mostat wire to use for the length of lead required in your installation.

Thermostat

Wire / Gauge

18

16

14

1.Install the wall thermostat in the desired location and run the wires to the stove location. Terminate these leads with 1/4” female connectors.

2.Connect the thermostat wires to the valve. (Fig. 51)

Install the Front Plate

Hold the front plate by the window bars and lift it into position, engaging the two steel tabs on the top corners behind the adjacent bosses in the side plates. (Fig. 52) Then seat the Front against the sides so the tabs at the bottom lip engage with the notches in the stove legs.

When properly installed, the bottom of the Front Plate cannot be pulled away from the sides without also lifting it.

Engage steel tabs gehind the cast iron bosses

Control Door

Bottom tabs engage

 

notch in the leg.

ST474

Fig. 52 Install the front plate.

This completes assembly of the Stardance stove.

Operation

�������

��������������

������������

������������������

�������������

��������������������

���������������

The Stardance is operated with the front plate in place with the doors open or closed. To open the front doors, pull forward to separate the magnetic catch.

CAUTION: DO NOT TOUCH DOORS WHEN HOT!

Your First Fire

Read these instructions carefully and familiarize your- self with the burner controls. Locate the pilot assembly, Figure 53. Follow the lighting instructions on Page 31 exactly.

During the first fire, it is not unusual to smell some odor associated with new logs, paint and metal being heated. Odors should dissipate within an hour or so, however, you can open a window to provide fresh air to alleviate the condition.

ST935

Fig. 53 Pilot assembly location.

Pilot and Burner Inspection

Each time you light your heater check that the pilot flame and burner flame patterns are as shown in Figure

55.If flame patterns are incorrect, turn the heater off. Contact your dealer or a qualified gas technician for as- sistance. Do not operate the heater until the pilot flame is correct.

Follow regular maintenance procedures as described on Page 41.

20012734

29

Image 29
Contents Stardance Direct Vent/Natural Vent Gas Heater Table of Contents General Information Gas Equipment Venting System not Provided Installation RequirementsStardance dimensions Stardance Direct Vent / Natural Vent DimensionsMinimum Clearances to Combustible Clearance RequirementsMaterials Locating the StoveWall and Ceiling Clearances Wall Centerline from FloorHearth Requirements Direct Vent OnlyGas Inlet and Manifold Pressures Gas SpecificationsHigh Elevations Horizontal Termination Direct Vent onlyRestrictor Plate Adjustment Restrictor Plate Adjustment For Extended Pipe RunsRestrictor Plate is used on Direct Vent Installations Only Examples for Extended Run/Restrictor Plate SettingsDirect Vent Only Vent Termination ClearancesLocation of Vent Termination General Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances Venting Requirements Natural Vent OnlyApproved Vent System Components Venting Requirements and Options Direct Vent onlySimpson DuraVent Components Minimum Horizontal Vent Kit 2792CFM Vent Components Remove rear skirt insert Install the Optional FanVenting System Assemlby Direct Vent General Information Install the Vent Adapter PipeSelkirk Corporation Vent Components Install Vent Adapter PipeSide Wall Termination Assembly Assemble the wall sleeve and firestop Vent Termination Below Grade Vertical Through the Roof Vent AssemblySelkirk Direct-Temp Metalbestos Direct Vent System Horizontal Venting Vertical VentingInlet End Outlet End To Termination To ApplianceSupporting DIRECT-TEMP Vertical Support Adjustable Length AJOffsets Supporting DIRECT-TEMP Horizontal SupportBelow grade installation Vertical Installation Fig Minimum Height Above Roof Requirements Venting System Assembly Natural Vent General InformationInstall the Log Set Install the Vent PipeStardance Direct Vent/Natural Vent Gas Heater Burner Information Install ON/OFF SwitchConnect the Gas Supply Line Operation Install the Front PlateThermostat Connection optional Your First FireFlame Characteristics Flame & Temperature AdjustmentSddvt Series Sddvtc Series Comfort Control ModelsTo Turn Off Gas To Heater Lighting and Operating InstructionsEuro SIT HoneywellSIT Nova 820 Millivolt Valve Troubleshooting the Gas Control System Sddvt SeriesTransmitter Operation Off Mode Shut Off ProcedureOn Manual Mode Delay Timer ModeFan Override During Auto Mode Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionOn Path Local PathAuto Path Conversion Procedure Conversion PrecautionsFuel Conversion Instructions Valve Conversion Sddvt Series ModelsValve Pilot Orifice ConversionPilot Type Bottom View Burner Orifice ConversionAll Models Conversion to Natural Gas Input BTU/h Injector Orifice Size MatrixConversion to LP Input BTU/h Logset and Burner Cleaning and Inspection MaintenanceCleaning the Glass Glass ReplacementStove Disassembly Gasket ReplacementInspect the Vent System Annually Check the Gas Flame RegularlyOn/Off Switch Wiring Wiring DiagramsOptional Thermostat Wiring Schematic DiagramStardance Direct Vent/Natural Vent Gas Heater Description Stardance Direct Vent/Natural Vent Gas HeaterFuel Conversion Kits Optional Accessories Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Limited Lifetime Warranty CFM Corporation

SDDVT specifications

Vermont Casting's SDDVT, or the Signature Series Direct Vent Technology, represents a remarkable blend of design, efficiency, and functionality in the world of high-performance heating appliances. Known for its commitment to craftsmanship, Vermont Casting has long been synonymous with quality, and the SDDVT is no exception.

One of the standout features of the SDDVT is its advanced direct venting capability. This system allows for efficient venting of combustion gases directly outside, minimizing the risk of backdrafting and ensuring optimal indoor air quality. It draws air from the outside for combustion, creating a more controlled environment that enhances both efficiency and safety. Homeowners can rest easy knowing that the SDDVT provides a reliable heating solution while protecting indoor air quality.

Another significant aspect of the SDDVT is its high-efficiency performance. With an impressive Annual Fuel Utilization Efficiency (AFUE) rating, the SDDVT maximizes heat output while minimizing fuel consumption. This efficiency translates to lower energy bills and a reduced carbon footprint, making it an environmentally friendly choice for heating. The unit is designed to operate effectively even in extremely cold temperatures, ensuring comfort throughout the winter months.

The SDDVT also boasts an array of customizable options that appeal to a wide range of aesthetic preferences. Available in various finishes and styles, including traditional cast iron and sleek modern designs, homeowners can select a model that complements their decor. The unit features a large viewing glass that provides an unobstructed view of the flames, creating a cozy ambiance that enhances the living space.

Incorporating cutting-edge technology, the SDDVT includes electronic ignition and advanced control systems, allowing users to easily manage their heating preferences. The integration of smart technology enables compatibility with home automation systems, giving users added convenience and control.

Overall, Vermont Casting's SDDVT is an exemplary heating solution characterized by its innovative direct venting technology, high efficiency, and customizable design options. With a focus on quality and performance, this unit exemplifies the brand's dedication to providing sustainable and effective heating solutions tailored to modern living. Whether for new construction or retrofitting existing spaces, the SDDVT stands as a premier choice for comfort and style.