Vermont Casting SDDVT manual Stardance Direct Vent/Natural Vent Gas Heater, Description

Page 45

Stardance Direct Vent/Natural Vent Gas Heater

Stardance Direct Vent/Natural Vent Gas Heater

SDDVT Series: SDDVTCB, SDDVTEB, SDDVTMB, SDDVTBS, SDDVTCH, SDDVTVG,

SDDVTBD,

SDDVTC Series: SDDVTCCB, SDDVTCEB, SDDVTCMB, SDDVTCBS, SDDVTCCH,

SDDVTCVG, SDDVTCBD

Ref.

Description

SDDVT/SDDVTC

1.

Log Set - Complete

20012551

1a.

Log Rear

20012546

1b.

Log Right

20012548

1c.

Log Left

20012547

1d.

Log Top

20012915

2.

Ember Bed Assembly

20012492

3.

Top

Refer to Enamel Parts Chart

4.

Front, Operable Door

Refer to Enamel Parts Chart

5.

Door Right

Refer to Enamel Parts Chart

6.

Door Left

Refer to Enamel Parts Chart

7.

Left End

Refer to Enamel Parts Chart

8.

Right End

Refer to Enamel Parts Chart

9.

Door, Control

1301087

10.

Glass Frame Assembly

30000127

11.

Glass

1601691

12.

Gasket, Glass - Med. Knit

1203702

13.

Nut, Hex Jam 3/8-16 TOPLK-Z

1203290

14.

Pawl Assy, Ash Door

5004025

15.

Front Steel Handle/Shaft - NI/VER

30002717

16.

Restrictor Plate

20013026

17.

FK26 Fan Subassembly (SDDVTC Series Only)

30000879

18.

Valve Nova SIT820.852 RN

20012218

19.

Valve Gas Honeywell Convertible RFN RV8310E

20003719

20a.

Pilot Assembly 3Way N/DV RN 0.199.706

10002264

 

Pilot Assembly 3Way N/DV RP 0.199.703

10002265

20b.

Pilot, PSE - NA175

20001115

 

Pilot, PSE - LP175

20001116

20c.

Pilot Assembly 3Way DV/RFN CS3003A2009

20002266

 

Pilot Assembly 3Way DV/RFP CS3003A2017

20002268

21.

Pilot Top Convertible

10002266

22.

Thermocouple 24”

53373

 

 

7531137

23.

Electrode Ignitor w/Cable SIT24

10001297

24.

Thermopile 18” RS

51827

 

 

7533113

25.

Nut Electrode SIT #0.974.144

57886

26.

Tubing Pilot w/Fittings 1/8 x 24”

10001296

27.

Thermopile - PSE for RF Pilots

20002400

28a.

Pilot Orifice #62 - NG Top Convertible

10002268

28b.

Pilot Orifice #35 - LP Top Convertible

10002269

29a.

Pilot Orifice PSE RFN

20000908

29b.

Pilot Orifice PSE RFP

20000907

30a.

Orifice Hood #53 (.0595”) LP

20007347

30b.

Orifice Hood #38 (0.101”) Nat.

20009310

20012734

45

Image 45
Contents Stardance Direct Vent/Natural Vent Gas Heater Table of Contents General Information Gas Equipment Venting System not Provided Installation RequirementsStardance dimensions Stardance Direct Vent / Natural Vent DimensionsMinimum Clearances to Combustible Clearance RequirementsMaterials Locating the StoveWall and Ceiling Clearances Wall Centerline from FloorHearth Requirements Direct Vent OnlyGas Inlet and Manifold Pressures Gas SpecificationsHigh Elevations Horizontal Termination Direct Vent onlyRestrictor Plate Adjustment Restrictor Plate Adjustment For Extended Pipe RunsRestrictor Plate is used on Direct Vent Installations Only Examples for Extended Run/Restrictor Plate SettingsVent Termination Clearances Location of Vent TerminationDirect Vent Only General Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances Venting Requirements Natural Vent OnlyApproved Vent System Components Venting Requirements and Options Direct Vent onlySimpson DuraVent Components Minimum Horizontal Vent Kit 2792CFM Vent Components Remove rear skirt insert Install the Optional FanVenting System Assemlby Direct Vent General Information Install the Vent Adapter PipeInstall Vent Adapter Pipe Side Wall Termination AssemblySelkirk Corporation Vent Components Assemble the wall sleeve and firestop Vent Termination Below Grade Vertical Through the Roof Vent AssemblySelkirk Direct-Temp Metalbestos Direct Vent System Horizontal Venting Vertical VentingInlet End Outlet End To Termination To ApplianceSupporting DIRECT-TEMP Vertical Support Adjustable Length AJOffsets Supporting DIRECT-TEMP Horizontal SupportBelow grade installation Vertical Installation Fig Minimum Height Above Roof Requirements Venting System Assembly Natural Vent General InformationInstall the Log Set Install the Vent PipeStardance Direct Vent/Natural Vent Gas Heater Install ON/OFF Switch Connect the Gas Supply LineBurner Information Operation Install the Front PlateThermostat Connection optional Your First FireFlame Characteristics Flame & Temperature AdjustmentSddvt Series Sddvtc Series Comfort Control ModelsTo Turn Off Gas To Heater Lighting and Operating InstructionsEuro SIT HoneywellSIT Nova 820 Millivolt Valve Troubleshooting the Gas Control System Sddvt SeriesTransmitter Operation Off Mode Shut Off ProcedureOn Manual Mode Delay Timer ModeFan Override During Auto Mode Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionOn Path Local PathAuto Path Conversion Procedure Conversion PrecautionsFuel Conversion Instructions Valve Conversion Sddvt Series ModelsPilot Orifice Conversion Pilot TypeValve Burner Orifice Conversion All ModelsBottom View Injector Orifice Size Matrix Conversion to LP Input BTU/hConversion to Natural Gas Input BTU/h Logset and Burner Cleaning and Inspection MaintenanceCleaning the Glass Glass ReplacementStove Disassembly Gasket ReplacementInspect the Vent System Annually Check the Gas Flame RegularlyOn/Off Switch Wiring Wiring DiagramsOptional Thermostat Wiring Schematic DiagramStardance Direct Vent/Natural Vent Gas Heater Description Stardance Direct Vent/Natural Vent Gas HeaterFuel Conversion Kits Optional Accessories Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Limited Lifetime Warranty CFM Corporation

SDDVT specifications

Vermont Casting's SDDVT, or the Signature Series Direct Vent Technology, represents a remarkable blend of design, efficiency, and functionality in the world of high-performance heating appliances. Known for its commitment to craftsmanship, Vermont Casting has long been synonymous with quality, and the SDDVT is no exception.

One of the standout features of the SDDVT is its advanced direct venting capability. This system allows for efficient venting of combustion gases directly outside, minimizing the risk of backdrafting and ensuring optimal indoor air quality. It draws air from the outside for combustion, creating a more controlled environment that enhances both efficiency and safety. Homeowners can rest easy knowing that the SDDVT provides a reliable heating solution while protecting indoor air quality.

Another significant aspect of the SDDVT is its high-efficiency performance. With an impressive Annual Fuel Utilization Efficiency (AFUE) rating, the SDDVT maximizes heat output while minimizing fuel consumption. This efficiency translates to lower energy bills and a reduced carbon footprint, making it an environmentally friendly choice for heating. The unit is designed to operate effectively even in extremely cold temperatures, ensuring comfort throughout the winter months.

The SDDVT also boasts an array of customizable options that appeal to a wide range of aesthetic preferences. Available in various finishes and styles, including traditional cast iron and sleek modern designs, homeowners can select a model that complements their decor. The unit features a large viewing glass that provides an unobstructed view of the flames, creating a cozy ambiance that enhances the living space.

Incorporating cutting-edge technology, the SDDVT includes electronic ignition and advanced control systems, allowing users to easily manage their heating preferences. The integration of smart technology enables compatibility with home automation systems, giving users added convenience and control.

Overall, Vermont Casting's SDDVT is an exemplary heating solution characterized by its innovative direct venting technology, high efficiency, and customizable design options. With a focus on quality and performance, this unit exemplifies the brand's dedication to providing sustainable and effective heating solutions tailored to modern living. Whether for new construction or retrofitting existing spaces, the SDDVT stands as a premier choice for comfort and style.