The Stardance Direct Vent/Natural Vent Room Heater, Model Nos. SDDVTCB, SDDVTEB, SDDVTMB, SDDVTBS, SDDVTCH, SDDVTVG, SDDVTBD, SDDVTCCB, SDDVTCEB, SDDVTC- MB, SDDVTCBS, SDDVTCCH, SDDVTCVG, SDDVTCCBD, is a vented gas appliance listed to the ANSI standard Z21.88-2005 and CSA-2.33-2005 for Vented Room Heaters, and CSA 2.17- M91, Gas-Fired Appliances For Use at High Altitudes.
The installation of the Stardance Direct Vent/Natural Vent Room Heater must conform with local codes, or in the absence of lo- cal codes, with National Fuel Gas Code, ANSI Z223.1/NFPA 54
—latest edition and CSA B-149.1 Installation Code. (EXCEP- TION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5” w.c. for Natural Gas and 10.0” w.c. for LP gas at maximum input.)
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.
Installation and replacement of gas piping, gas utilization equipment or accessories, and repair and servicing of equipment shall be performed only by a qualified agency, preferably NFI or WETT (Canada) certified. The term “quali- fied agency” means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) installation or re- placement of gas piping, or (b), the connection, installation, repair, or servicing of equipment, who is experienced in such work, familiar with all precautions required, and has complied with all the requirements of the authority having jurisdiction.
The Stardance Direct Vent/Natural Vent Room Heater should be inspected before use and at least annually by a qualified service agency. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean.
The Stardance Direct Vent/Natural Vent Room Heater and its individual shut-off valve must be disconnected from the gas sup- ply piping during any pressure testing of that system at test pres- sures in excess of 1/2 psig (3.5 kPa).
The Stardance Direct Vent/Natural Vent Room Heater must be isolated from the gas supply piping system by closing its indi- vidual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig.
‘Direct Vent’ describes a sealed combustion system in which in- coming outside air for combustion and outgoing exhaust enter and exit through two separate concentric passages within the same sealed vent system. The system does not use room air to support combustion. The Direct Vent system permits the gas ap- pliance to be vented directly to the outside atmosphere through the side of the house or vertically through the roof. Conventional venting systems (Natural Vent) take air from the room for com- bustion and vent the exhaust vertically through the roof to the atmosphere.
This appliance is approved for bedroom installations in the U.S. and Canada.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.
WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.
The Stardance Direct Vent/Natural Vent Room Heater, when in- stalled, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electri- cal Code ANSI/NFPA 70, (latest edition), or of the current Cana- dian Electrical Code C22.1.
Due to high temperatures this appliance should be located out of traffic and away from furniture and draperies.
WARNING: This appliance is hot while in operation. Keep children, clothing, and furniture away. Contact may cause burns or ignition of combustible materials.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Young children should be carefully su- pervised when they are in the same room as the appliance.
Clothing or other flammable materials should not be placed on or near the appliance.
Any safety screen, glass or guard removed for servicing an appliance must be replaced prior to operating the appli- ance.
The appliance area must be kept clear and free from com- bustible materials, gasoline, and other flammable vapors and liquids.
The flow of combustion and ventilation air must not be ob- structed. The installation must include adequate accessibil- ity and clearance for servicing and proper operation.
WARNING: Do not operate the Room Heater with the glass panel removed, cracked or broken. Replacement of the pan- el should be done by a licensed or qualified service person.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
Do not burn wood, trash or any other material for which this appliance was not designed. This appliance is designed to burn either natural gas or propane only.
This gas appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance.
CAUTION: Label all wires prior to disconnection when ser- vicing controls. Wiring errors can cause improper and dan- gerous operation.
Verify proper operation after servicing.
*Aftermarket: Completion of sale, nor for purpose of resale, from the manufacturer.
Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm.
California Health & Safety Code Sec. 25249.6