Maintenance

Your Stardance Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly.

Annual System Inspection

Have the entire heater and venting system inspected annually by a qualified gas technician. Replace any worn or broken parts.

Logset and Burner /

Cleaning and Inspection

Cleanliness is critical to the proper function of the heater. The logset and burner must all be kept free of dust and unobstructed by debris. Inspect these areas before each use and clean as necessary.

1.Turn the burner OFF and let the heater cool com- pletely before cleaning.

2.Lift the Stove Front up and then swing the bottom out to disengage it from the heater shell. (Fig. 75)

3.Carefully remove the glass and frame assembly and place it out of the way on a flat, padded surface such as a counter protected by a towel.

4.Carefully inspect the Logs for damage. Contact your local dealer if any damage is evident. DO NOT OP-

ERATE THE HEATER WITH DAMAGED LOGS.

5.Use a soft bristled brush to sweep dust or debris from the Logs, Pilot and Burner. Use care as the logs are fragile and susceptible to damage. DO NOT USE

A VACUUM TO CLEAN THE LOGS OR BURNER.

6.Replace the glass panel and frame assembly.

7.Replace the Stove Front.

Care of Cast Iron

An occasional dusting with a dry rag will help keep the painted surfaces looking new. Use high-temperature stove paints, available through your local dealer, to touch-up areas as needed. Clean areas to be painted with a wire brush and be sure to cover the logs, burner and valve assembly, glass and frame assembly. Apply the paint sparingly; two light coats of paint will give bet- ter results than a single heavy coat.

Clean porcelain enamel surfaces with a soft, damp cloth. Do not use abrasive cleaning agents. If neces- sary, use only a cleaning agent formulated especially for use on porcelain enamel surfaces.

CAUTION

TURN THE PILOT OFF BEFORE PAINTING. AL- LOW THE HEATER TO COOL COMPLETELY BE- FORE PAINTING.

Cleaning the Glass

WARNING: Allow the glass to cool com- pletely before attempting to clean.

�������

��������������

������������

������������������

�������������

��������������������

���������������

It will be necessary to clean the glass periodically. Dur- ing start-up, condensation, which is normal, forms on the inside of the glass and causes lint, dust and other airborne particles to cling to the glass surface. Also initial paint curing may deposit a slight film on the glass. It is therefore recommended that the glass be cleaned two or three times with a non-ammonia household cleaner and warm water (we recommend gas fireplace glass cleaner). After that the glass should be cleaned two or three times during each heating season depend- ing on the circumstances present.

Clean glass after first two weeks of opera- tion.

Glass Replacement

Replace glass only with CFM Corporation approved parts. Refer to Page 44 for Replacement Parts. Refer to Figures 75 & 76 for removal of the damaged glass frame.

ST474a

Fig. 75 Remove the stove front.

20012734

41

Image 41
Contents Stardance Direct Vent/Natural Vent Gas Heater Table of Contents General Information Gas Equipment Venting System not Provided Installation RequirementsStardance dimensions Stardance Direct Vent / Natural Vent DimensionsMinimum Clearances to Combustible Clearance RequirementsMaterials Locating the StoveWall and Ceiling Clearances Wall Centerline from FloorHearth Requirements Direct Vent OnlyGas Inlet and Manifold Pressures Gas SpecificationsHigh Elevations Horizontal Termination Direct Vent onlyRestrictor Plate Adjustment Restrictor Plate Adjustment For Extended Pipe RunsRestrictor Plate is used on Direct Vent Installations Only Examples for Extended Run/Restrictor Plate SettingsDirect Vent Only Vent Termination ClearancesLocation of Vent Termination General Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances Venting Requirements Natural Vent OnlyApproved Vent System Components Venting Requirements and Options Direct Vent onlySimpson DuraVent Components Minimum Horizontal Vent Kit 2792CFM Vent Components Remove rear skirt insert Install the Optional FanVenting System Assemlby Direct Vent General Information Install the Vent Adapter PipeSelkirk Corporation Vent Components Install Vent Adapter PipeSide Wall Termination Assembly Assemble the wall sleeve and firestop Vent Termination Below Grade Vertical Through the Roof Vent AssemblySelkirk Direct-Temp Metalbestos Direct Vent System Horizontal Venting Vertical VentingInlet End Outlet End To Termination To ApplianceSupporting DIRECT-TEMP Vertical Support Adjustable Length AJOffsets Supporting DIRECT-TEMP Horizontal SupportBelow grade installation Vertical Installation Fig Minimum Height Above Roof Requirements Venting System Assembly Natural Vent General InformationInstall the Log Set Install the Vent PipeStardance Direct Vent/Natural Vent Gas Heater Burner Information Install ON/OFF SwitchConnect the Gas Supply Line Operation Install the Front PlateThermostat Connection optional Your First FireFlame Characteristics Flame & Temperature AdjustmentSddvt Series Sddvtc Series Comfort Control ModelsTo Turn Off Gas To Heater Lighting and Operating InstructionsEuro SIT HoneywellSIT Nova 820 Millivolt Valve Troubleshooting the Gas Control System Sddvt SeriesTransmitter Operation Off Mode Shut Off ProcedureOn Manual Mode Delay Timer ModeFan Override During Auto Mode Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionOn Path Local PathAuto Path Conversion Procedure Conversion PrecautionsFuel Conversion Instructions Valve Conversion Sddvt Series ModelsValve Pilot Orifice ConversionPilot Type Bottom View Burner Orifice ConversionAll Models Conversion to Natural Gas Input BTU/h Injector Orifice Size MatrixConversion to LP Input BTU/h Logset and Burner Cleaning and Inspection MaintenanceCleaning the Glass Glass ReplacementStove Disassembly Gasket ReplacementInspect the Vent System Annually Check the Gas Flame RegularlyOn/Off Switch Wiring Wiring DiagramsOptional Thermostat Wiring Schematic DiagramStardance Direct Vent/Natural Vent Gas Heater Description Stardance Direct Vent/Natural Vent Gas HeaterFuel Conversion Kits Optional Accessories Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Limited Lifetime Warranty CFM Corporation

SDDVT specifications

Vermont Casting's SDDVT, or the Signature Series Direct Vent Technology, represents a remarkable blend of design, efficiency, and functionality in the world of high-performance heating appliances. Known for its commitment to craftsmanship, Vermont Casting has long been synonymous with quality, and the SDDVT is no exception.

One of the standout features of the SDDVT is its advanced direct venting capability. This system allows for efficient venting of combustion gases directly outside, minimizing the risk of backdrafting and ensuring optimal indoor air quality. It draws air from the outside for combustion, creating a more controlled environment that enhances both efficiency and safety. Homeowners can rest easy knowing that the SDDVT provides a reliable heating solution while protecting indoor air quality.

Another significant aspect of the SDDVT is its high-efficiency performance. With an impressive Annual Fuel Utilization Efficiency (AFUE) rating, the SDDVT maximizes heat output while minimizing fuel consumption. This efficiency translates to lower energy bills and a reduced carbon footprint, making it an environmentally friendly choice for heating. The unit is designed to operate effectively even in extremely cold temperatures, ensuring comfort throughout the winter months.

The SDDVT also boasts an array of customizable options that appeal to a wide range of aesthetic preferences. Available in various finishes and styles, including traditional cast iron and sleek modern designs, homeowners can select a model that complements their decor. The unit features a large viewing glass that provides an unobstructed view of the flames, creating a cozy ambiance that enhances the living space.

Incorporating cutting-edge technology, the SDDVT includes electronic ignition and advanced control systems, allowing users to easily manage their heating preferences. The integration of smart technology enables compatibility with home automation systems, giving users added convenience and control.

Overall, Vermont Casting's SDDVT is an exemplary heating solution characterized by its innovative direct venting technology, high efficiency, and customizable design options. With a focus on quality and performance, this unit exemplifies the brand's dedication to providing sustainable and effective heating solutions tailored to modern living. Whether for new construction or retrofitting existing spaces, the SDDVT stands as a premier choice for comfort and style.