Stardance Direct Vent/Natural Vent Gas Heater

Lighting and Operating Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

A.This heater has a pilot which must be lit manu- ally. When lighting the pilot follow these instruc- tions exactly.

B.BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a neighbor’s phone.

Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service techni- cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Lighting Instructions

1.STOP! Read the safety information above.

2.Turn off all electrical power to the fireplace.

3.Turn the ON/OFF switch to “OFF” position, set the remote to OFF or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn clock-

wise to “OFF”.

 

 

 

 

 

PILOT

PILOT

OFF

 

 

 

 

 

 

t

 

1

F

 

 

 

 

 

 

 

 

 

lo

 

 

 

ON

ON

 

P

 

 

 

 

F

 

 

F

 

 

i

 

2

 

 

 

 

 

O

 

O

 

 

 

F

 

 

 

 

 

 

 

5

 

3

 

 

FFO

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

Euro SIT

 

SIT NOVA

Honeywell

6.Remove glass door before lighting pilot. (See Glass Frame Removal section).

7.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety infor- mation above. If you do not smell gas, go to the next step.

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counterclockwise

to “PILOT”.

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depress- ing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one

(1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

3/8" - 1/2"

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If after several tries, the pilot will not stay lit, turn the gas control knob to “OFF” and call your service technician or gas supplier.

11.Replace glass door.

12.Turn gas control knob to “ON” position.

13.Turn the ON/OFF switch to “ON” position or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

To Turn Off Gas To Heater

1.Turn the ON/OFF switch to Off position or set the thermostat to lowest setting.

2.Turn off all electric power to the fireplace if service is to be performed.

3.Open control access panel.

4.Push in gas control knob slightly and turn clock-

wise to “OFF”. Do not force.

5.Close control access panel.

20012734

31

Image 31
Contents Stardance Direct Vent/Natural Vent Gas Heater Table of Contents General Information Gas Equipment Venting System not Provided Installation RequirementsStardance dimensions Stardance Direct Vent / Natural Vent DimensionsLocating the Stove Clearance RequirementsMinimum Clearances to Combustible MaterialsDirect Vent Only Wall Centerline from FloorWall and Ceiling Clearances Hearth RequirementsHorizontal Termination Direct Vent only Gas SpecificationsGas Inlet and Manifold Pressures High ElevationsExamples for Extended Run/Restrictor Plate Settings Restrictor Plate Adjustment For Extended Pipe RunsRestrictor Plate Adjustment Restrictor Plate is used on Direct Vent Installations OnlyLocation of Vent Termination Vent Termination ClearancesDirect Vent Only General Venting Information Termination Location Canadian Installations1 US Installations2Termination Clearances Venting Requirements Natural Vent OnlyMinimum Horizontal Vent Kit 2792 Venting Requirements and Options Direct Vent onlyApproved Vent System Components Simpson DuraVent ComponentsCFM Vent Components Remove rear skirt insert Install the Optional FanVenting System Assemlby Direct Vent General Information Install the Vent Adapter PipeSide Wall Termination Assembly Install Vent Adapter PipeSelkirk Corporation Vent Components Assemble the wall sleeve and firestop Vent Termination Below Grade Vertical Through the Roof Vent AssemblySelkirk Direct-Temp Metalbestos Direct Vent System To Appliance Vertical VentingHorizontal Venting Inlet End Outlet End To TerminationSupporting DIRECT-TEMP Horizontal Support Adjustable Length AJSupporting DIRECT-TEMP Vertical Support OffsetsBelow grade installation Vertical Installation Fig Minimum Height Above Roof Requirements Venting System Assembly Natural Vent General InformationInstall the Log Set Install the Vent PipeStardance Direct Vent/Natural Vent Gas Heater Connect the Gas Supply Line Install ON/OFF SwitchBurner Information Your First Fire Install the Front PlateOperation Thermostat Connection optionalSddvtc Series Comfort Control Models Flame & Temperature AdjustmentFlame Characteristics Sddvt SeriesHoneywell Lighting and Operating InstructionsTo Turn Off Gas To Heater Euro SITSIT Nova 820 Millivolt Valve Troubleshooting the Gas Control System Sddvt SeriesDelay Timer Mode Shut Off ProcedureTransmitter Operation Off Mode On Manual ModeDisable Thermostat Function Auto ModeFan Override During Auto Mode Change Between F/C Temperature UnitsOn Path Local PathAuto Path Valve Conversion Sddvt Series Models Conversion PrecautionsConversion Procedure Fuel Conversion InstructionsPilot Type Pilot Orifice ConversionValve All Models Burner Orifice ConversionBottom View Conversion to LP Input BTU/h Injector Orifice Size MatrixConversion to Natural Gas Input BTU/h Glass Replacement MaintenanceLogset and Burner Cleaning and Inspection Cleaning the GlassCheck the Gas Flame Regularly Gasket ReplacementStove Disassembly Inspect the Vent System AnnuallySchematic Diagram Wiring DiagramsOn/Off Switch Wiring Optional Thermostat WiringStardance Direct Vent/Natural Vent Gas Heater Description Stardance Direct Vent/Natural Vent Gas HeaterFuel Conversion Kits Optional Accessories Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Limited Lifetime Warranty CFM Corporation

SDDVT specifications

Vermont Casting's SDDVT, or the Signature Series Direct Vent Technology, represents a remarkable blend of design, efficiency, and functionality in the world of high-performance heating appliances. Known for its commitment to craftsmanship, Vermont Casting has long been synonymous with quality, and the SDDVT is no exception.

One of the standout features of the SDDVT is its advanced direct venting capability. This system allows for efficient venting of combustion gases directly outside, minimizing the risk of backdrafting and ensuring optimal indoor air quality. It draws air from the outside for combustion, creating a more controlled environment that enhances both efficiency and safety. Homeowners can rest easy knowing that the SDDVT provides a reliable heating solution while protecting indoor air quality.

Another significant aspect of the SDDVT is its high-efficiency performance. With an impressive Annual Fuel Utilization Efficiency (AFUE) rating, the SDDVT maximizes heat output while minimizing fuel consumption. This efficiency translates to lower energy bills and a reduced carbon footprint, making it an environmentally friendly choice for heating. The unit is designed to operate effectively even in extremely cold temperatures, ensuring comfort throughout the winter months.

The SDDVT also boasts an array of customizable options that appeal to a wide range of aesthetic preferences. Available in various finishes and styles, including traditional cast iron and sleek modern designs, homeowners can select a model that complements their decor. The unit features a large viewing glass that provides an unobstructed view of the flames, creating a cozy ambiance that enhances the living space.

Incorporating cutting-edge technology, the SDDVT includes electronic ignition and advanced control systems, allowing users to easily manage their heating preferences. The integration of smart technology enables compatibility with home automation systems, giving users added convenience and control.

Overall, Vermont Casting's SDDVT is an exemplary heating solution characterized by its innovative direct venting technology, high efficiency, and customizable design options. With a focus on quality and performance, this unit exemplifies the brand's dedication to providing sustainable and effective heating solutions tailored to modern living. Whether for new construction or retrofitting existing spaces, the SDDVT stands as a premier choice for comfort and style.