Vermont Casting SDDVT manual Clearance Requirements, Minimum Clearances to Combustible, Materials

Page 6

Stardance Direct Vent/Natural Vent Gas Heater

Installation Requirements

The installation must conform with local codes or, in

 

 

 

 

 

 

the absence of local codes, with the National Fuel Gas

 

 

 

Code, ANSI Z223.1/NFPA 54 - latest edition. (EXCEP-

 

 

 

TION: Do not derate this appliance for altitude. Main-

 

A

 

tain the manifold pressure at 3.5 inches w.c. for Natural

 

D

Gas, and 10 inches w.c. for Propane).

 

B

 

In Canada, installation must be in accordance with the

 

C

 

current CSA B-149.1 Installation Codes and/or local

 

 

 

codes.

 

E

 

The installation should be done by a qualified ser-

 

 

 

vice person who is familiar with the building codes

 

 

 

and installation techniques appropriate for your

 

 

ST207

area to accomplish a safe and effective installation.

 

 

 

 

 

 

Fig. 2 Possible stove locations.

 

Your dealer or your local gas supplier will be able to

 

 

 

 

 

refer a qualified service person.

 

 

 

 

Clearance Requirements

WARNING: Due to high temperatures, the

 

 

Minimum Clearances to Combustible

HEATER should be located out of traffic

 

and away from furniture and draperies.

 

Materials

 

The surface of the Heater Is hot when it is in use.

 

 

 

Measure side clearances as shown in Figures 3 and 4

Young children should be watched carefully when

 

from the outer edge of the cast iron stove top. Measure

they are in the same room when the Heater is in

 

rear clearances from the outermost surface of the steel

use, and they should be taught to avoid the hot

 

rear skirt.

 

surface. Keep any objects that can burn well away

 

The Stardance heater is approved for installation into

from the Heater, and observe the recommended

 

 

an alcove constructed of combustible materials to the

clearances that follow.

 

 

dimensions and clearances shown on the next page.

�������

 

 

lation.

 

 

 

The same clearances apply in a standard parallel instal-

��������������

 

 

 

 

 

 

������������

 

Warning:

 

������������������

 

• Always maintain required clearances

�������������

 

(air spaces) to nearby combustibles to prevent

��������������������

 

fire hazard. Do not fill air spaces with insula-

 

tion. All venting components must maintain a

���������������

 

 

1” (25 mm) clearance to combustible materials.

 

 

Locating the Stove

 

Maintain a 6” (150 mm) clearance when using a

 

 

single wall pipe.

 

In choosing a location for the stove, consider:

 

 

 

• The gas appliance and vent system must be

• The location of outside walls;

 

 

vented directly to the outside of the building

• Where additional heat is needed:

 

 

and never be attached to a chimney serving a

• Where family members gather most often;

 

separate solid fuel or gas-burning appliance.

• The vent system requirements.

 

Each direct vent appliance must use its own

NOTE: We do not recommend the use of wallpaper

 

separate vent system. Common vents are pro-

 

hibited.

 

next to this stove. Over time, radiant heat may cause

 

 

 

• Refer to the manufacturer’s instructions in-

the wallpaper to shrink, or may adversely affect the

 

 

cluded with the venting system for complete

binders in the wallpaper adhesive.

 

 

installation procedures.

 

 

 

 

 

 

 

 

6

20012734

Image 6
Contents Stardance Direct Vent/Natural Vent Gas Heater Table of Contents General Information Installation Requirements Gas Equipment Venting System not ProvidedStardance Direct Vent / Natural Vent Dimensions Stardance dimensionsMaterials Clearance RequirementsMinimum Clearances to Combustible Locating the StoveHearth Requirements Wall Centerline from FloorWall and Ceiling Clearances Direct Vent OnlyHigh Elevations Gas SpecificationsGas Inlet and Manifold Pressures Horizontal Termination Direct Vent onlyRestrictor Plate is used on Direct Vent Installations Only Restrictor Plate Adjustment For Extended Pipe RunsRestrictor Plate Adjustment Examples for Extended Run/Restrictor Plate SettingsVent Termination Clearances Location of Vent TerminationDirect Vent Only Canadian Installations1 US Installations2 General Venting Information Termination LocationVenting Requirements Natural Vent Only Termination ClearancesSimpson DuraVent Components Venting Requirements and Options Direct Vent onlyApproved Vent System Components Minimum Horizontal Vent Kit 2792CFM Vent Components Install the Optional Fan Remove rear skirt insertInstall the Vent Adapter Pipe Venting System Assemlby Direct Vent General InformationInstall Vent Adapter Pipe Side Wall Termination AssemblySelkirk Corporation Vent Components Assemble the wall sleeve and firestop Vertical Through the Roof Vent Assembly Vent Termination Below GradeSelkirk Direct-Temp Metalbestos Direct Vent System Inlet End Outlet End To Termination Vertical VentingHorizontal Venting To ApplianceOffsets Adjustable Length AJSupporting DIRECT-TEMP Vertical Support Supporting DIRECT-TEMP Horizontal SupportBelow grade installation Vertical Installation Fig Venting System Assembly Natural Vent General Information Minimum Height Above Roof RequirementsInstall the Vent Pipe Install the Log SetStardance Direct Vent/Natural Vent Gas Heater Install ON/OFF Switch Connect the Gas Supply LineBurner Information Thermostat Connection optional Install the Front PlateOperation Your First FireSddvt Series Flame & Temperature AdjustmentFlame Characteristics Sddvtc Series Comfort Control ModelsEuro SIT Lighting and Operating InstructionsTo Turn Off Gas To Heater HoneywellTroubleshooting the Gas Control System Sddvt Series SIT Nova 820 Millivolt ValveOn Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Delay Timer ModeChange Between F/C Temperature Units Auto ModeFan Override During Auto Mode Disable Thermostat FunctionLocal Path On PathAuto Path Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Valve Conversion Sddvt Series ModelsPilot Orifice Conversion Pilot TypeValve Burner Orifice Conversion All ModelsBottom View Injector Orifice Size Matrix Conversion to LP Input BTU/hConversion to Natural Gas Input BTU/h Cleaning the Glass MaintenanceLogset and Burner Cleaning and Inspection Glass ReplacementInspect the Vent System Annually Gasket ReplacementStove Disassembly Check the Gas Flame RegularlyOptional Thermostat Wiring Wiring DiagramsOn/Off Switch Wiring Schematic DiagramStardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater DescriptionFuel Conversion Kits Optional Accessories Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Limited Lifetime Warranty CFM Corporation

SDDVT specifications

Vermont Casting's SDDVT, or the Signature Series Direct Vent Technology, represents a remarkable blend of design, efficiency, and functionality in the world of high-performance heating appliances. Known for its commitment to craftsmanship, Vermont Casting has long been synonymous with quality, and the SDDVT is no exception.

One of the standout features of the SDDVT is its advanced direct venting capability. This system allows for efficient venting of combustion gases directly outside, minimizing the risk of backdrafting and ensuring optimal indoor air quality. It draws air from the outside for combustion, creating a more controlled environment that enhances both efficiency and safety. Homeowners can rest easy knowing that the SDDVT provides a reliable heating solution while protecting indoor air quality.

Another significant aspect of the SDDVT is its high-efficiency performance. With an impressive Annual Fuel Utilization Efficiency (AFUE) rating, the SDDVT maximizes heat output while minimizing fuel consumption. This efficiency translates to lower energy bills and a reduced carbon footprint, making it an environmentally friendly choice for heating. The unit is designed to operate effectively even in extremely cold temperatures, ensuring comfort throughout the winter months.

The SDDVT also boasts an array of customizable options that appeal to a wide range of aesthetic preferences. Available in various finishes and styles, including traditional cast iron and sleek modern designs, homeowners can select a model that complements their decor. The unit features a large viewing glass that provides an unobstructed view of the flames, creating a cozy ambiance that enhances the living space.

Incorporating cutting-edge technology, the SDDVT includes electronic ignition and advanced control systems, allowing users to easily manage their heating preferences. The integration of smart technology enables compatibility with home automation systems, giving users added convenience and control.

Overall, Vermont Casting's SDDVT is an exemplary heating solution characterized by its innovative direct venting technology, high efficiency, and customizable design options. With a focus on quality and performance, this unit exemplifies the brand's dedication to providing sustainable and effective heating solutions tailored to modern living. Whether for new construction or retrofitting existing spaces, the SDDVT stands as a premier choice for comfort and style.