Vermont Casting SDDVT Fan Override During Auto Mode, Change Between F/C Temperature Units

Page 34

Stardance Direct Vent/Natural Vent Gas Heater

Auto Mode

In the AUTO mode, the room temperature, set tem- perature, flame and fan levels will be shown. AUTO will appear next to both the flame and fan icons.

When the control is in the AUTO mode, the main burner will turn on/off or modulate based on the heat needed to maintain the set temperature. The flame level will change automatically to optimize the heat output needed to maintain the set temperature. To change the set temperature, press the up or down key. Pushing a key once will change the temperature by one degree.

In the AUTO mode, the fan speed will increase with increasing flame height or decrease with decreasing flame height. “AUTO” is displayed next to the flame and fan icons.

Fan Override During Auto Mode

If a lower or higher fan speed is desired when operating in the AUTO mode, the fan speed can be overridden by pushing the fan button followed by the up or down key. Pushing a key once will change the fan level by one unit. In this mode “AUTO” is displayed next to the flame icon and “MANUAL” is displayed next to the fan icon.

Change Between F/C Temperature Units

Push the up and down arrow keys simultaneously for at least 3 seconds to toggle between Fahrenheit and Celsius units.

Disable Thermostat Function

To disable the thermostat function in the AUTO mode, push the time and down keys simultaneously for at least 3 seconds.

To Change Batteries

1.Remove cover on the backside of the transmitter. Install 3 AAA batteries as shown and reattach cover.

2.Once steps 1-3 in OPERATION are completed, receiver/valve and transmitter are now ready. Press any button on transmitter for recognition process to occur between the receiver/valve and transmitter.

3.Use functions as described in TRANSMITTER sec- tion.

Troubleshooting

1.Locate LED light on valve.

2.LED will blink after every valid command received by the transmitter; this is not an error.

3.Failure codes may occur anytime after pilot burner is lit.

4.Sequence is failure code followed by light not blink- ing for 30 seconds.

 

 

Pilot

 

 

 

Assembly

 

 

 

 

Fan

 

 

Red

FAN

 

 

 

 

Red

White

 

 

 

 

 

White

 

White Dots

 

 

 

 

 

Antenna

 

FP1038

 

Comfort Control Valve

 

 

(Bottom View)

 

 

 

 

Fig. 58

Comfort valve wiring diagram.

 

5.In the event of multiple failure codes, next failure code follows previous failure code by approximately 3 seconds.

If an Error Code 3 is observed while performing the testing, complete the following:

1.Make sure the spade connectors are pushed all the way on. If rhe Error Code 3 is still showing, then go to the next step.

2.Switch the front two thermopile leads with the back two. Be sure the white lead is connected to the spade with the white dot next to it. If the Error Code 3 is still showing, replace the thermopiles.

If an Error Code 8 is observed while performing the testing, complete the following:

1.Confirm the valve is not in REMOTE mode.

If the valve is producing Error Code 8 and in RE- MOTE mode, the valve is defective and should be replaced.

If the valve is in LOCAL mode and producing Error Code 8, then go to the next step.

2.Slide the Remote/Local switch to REMOTE and teach the valve a transmitter (see item 6, page 32). The Error Code will clear itself after approximately 1.5 minutes and return to normal operation.

LED Count

Service Action

8Replace valve

7Confirm stepper motor connection exists

5Confirm fan connection exists and works

4Confirm gas type; jumper in place

3Replace thermopiles

2Turn fan ON

NOTE: Some keys are not active.

34

20012734

Image 34
Contents Stardance Direct Vent/Natural Vent Gas Heater Table of Contents General Information Installation Requirements Gas Equipment Venting System not ProvidedStardance Direct Vent / Natural Vent Dimensions Stardance dimensionsMaterials Clearance RequirementsMinimum Clearances to Combustible Locating the StoveHearth Requirements Wall Centerline from FloorWall and Ceiling Clearances Direct Vent OnlyHigh Elevations Gas SpecificationsGas Inlet and Manifold Pressures Horizontal Termination Direct Vent onlyRestrictor Plate is used on Direct Vent Installations Only Restrictor Plate Adjustment For Extended Pipe RunsRestrictor Plate Adjustment Examples for Extended Run/Restrictor Plate SettingsLocation of Vent Termination Vent Termination ClearancesDirect Vent Only Canadian Installations1 US Installations2 General Venting Information Termination LocationVenting Requirements Natural Vent Only Termination ClearancesSimpson DuraVent Components Venting Requirements and Options Direct Vent onlyApproved Vent System Components Minimum Horizontal Vent Kit 2792CFM Vent Components Install the Optional Fan Remove rear skirt insertInstall the Vent Adapter Pipe Venting System Assemlby Direct Vent General InformationSide Wall Termination Assembly Install Vent Adapter PipeSelkirk Corporation Vent Components Assemble the wall sleeve and firestop Vertical Through the Roof Vent Assembly Vent Termination Below GradeSelkirk Direct-Temp Metalbestos Direct Vent System Inlet End Outlet End To Termination Vertical VentingHorizontal Venting To ApplianceOffsets Adjustable Length AJSupporting DIRECT-TEMP Vertical Support Supporting DIRECT-TEMP Horizontal SupportBelow grade installation Vertical Installation Fig Venting System Assembly Natural Vent General Information Minimum Height Above Roof RequirementsInstall the Vent Pipe Install the Log SetStardance Direct Vent/Natural Vent Gas Heater Connect the Gas Supply Line Install ON/OFF SwitchBurner Information Thermostat Connection optional Install the Front PlateOperation Your First FireSddvt Series Flame & Temperature AdjustmentFlame Characteristics Sddvtc Series Comfort Control ModelsEuro SIT Lighting and Operating InstructionsTo Turn Off Gas To Heater HoneywellTroubleshooting the Gas Control System Sddvt Series SIT Nova 820 Millivolt ValveOn Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Delay Timer ModeChange Between F/C Temperature Units Auto ModeFan Override During Auto Mode Disable Thermostat FunctionLocal Path On PathAuto Path Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Valve Conversion Sddvt Series ModelsPilot Type Pilot Orifice ConversionValve All Models Burner Orifice ConversionBottom View Conversion to LP Input BTU/h Injector Orifice Size MatrixConversion to Natural Gas Input BTU/h Cleaning the Glass MaintenanceLogset and Burner Cleaning and Inspection Glass ReplacementInspect the Vent System Annually Gasket ReplacementStove Disassembly Check the Gas Flame RegularlyOptional Thermostat Wiring Wiring DiagramsOn/Off Switch Wiring Schematic DiagramStardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater DescriptionFuel Conversion Kits Optional Accessories Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Limited Lifetime Warranty CFM Corporation

SDDVT specifications

Vermont Casting's SDDVT, or the Signature Series Direct Vent Technology, represents a remarkable blend of design, efficiency, and functionality in the world of high-performance heating appliances. Known for its commitment to craftsmanship, Vermont Casting has long been synonymous with quality, and the SDDVT is no exception.

One of the standout features of the SDDVT is its advanced direct venting capability. This system allows for efficient venting of combustion gases directly outside, minimizing the risk of backdrafting and ensuring optimal indoor air quality. It draws air from the outside for combustion, creating a more controlled environment that enhances both efficiency and safety. Homeowners can rest easy knowing that the SDDVT provides a reliable heating solution while protecting indoor air quality.

Another significant aspect of the SDDVT is its high-efficiency performance. With an impressive Annual Fuel Utilization Efficiency (AFUE) rating, the SDDVT maximizes heat output while minimizing fuel consumption. This efficiency translates to lower energy bills and a reduced carbon footprint, making it an environmentally friendly choice for heating. The unit is designed to operate effectively even in extremely cold temperatures, ensuring comfort throughout the winter months.

The SDDVT also boasts an array of customizable options that appeal to a wide range of aesthetic preferences. Available in various finishes and styles, including traditional cast iron and sleek modern designs, homeowners can select a model that complements their decor. The unit features a large viewing glass that provides an unobstructed view of the flames, creating a cozy ambiance that enhances the living space.

Incorporating cutting-edge technology, the SDDVT includes electronic ignition and advanced control systems, allowing users to easily manage their heating preferences. The integration of smart technology enables compatibility with home automation systems, giving users added convenience and control.

Overall, Vermont Casting's SDDVT is an exemplary heating solution characterized by its innovative direct venting technology, high efficiency, and customizable design options. With a focus on quality and performance, this unit exemplifies the brand's dedication to providing sustainable and effective heating solutions tailored to modern living. Whether for new construction or retrofitting existing spaces, the SDDVT stands as a premier choice for comfort and style.