Vermont Casting SDDVT Vent Termination Clearances, Location of Vent Termination, Direct Vent Only

Page 10

Stardance Direct Vent/Natural Vent Gas Heater

Vent Termination Clearances

When planning the installation, consider the location of the vent terminal and clearances. Some of the most common clearances to keep in mind are shown in Figure 11.

Important: All vent clearances must be maintained. Check your vent termination clearances against Figures 11 through 13.

The vent should be placed so that people cannot be burned by accidentally touching the vent surfaces when the stove is operating.

The vent termination should be located where it cannot be damaged by such things as automobile doors, lawn mowers or snowblowers and it should be located away from areas where it could become blocked by snow, etc.

Some considerations are:

Obstructions or impediments to venting.

Nearby combustible materials that could come into contact with combustion exhaust gases.

Other nearby openings {within 12” (305 mm)} through which exhaust gas could reenter the build- ing.

All vegetation within 3’ (76 mm) that may interfere with the draft.

Other factors that influence where the installation will be sited include the location of outside walls, where additional heat may be desired in the home, where the family members gather most regularly, and perhaps most importantly, the distance limitations of the venting system.

IMPORTANT

Direct Vent Only

The horizontal termination must not be recessed into the exterior wall or siding.

Horizontal vent runs must be level toward the vent termination.

Clearances around the vent termination must be maintained.

For installations using Simpson DuraVent pipe, parallel installations with minimum wall clearance have restricted access for connecting the Hori- zontal Vent Cap straps to the vent pipe. See the maker’s instructions for recommended installation procedures.

Your stove is approved to be vented either through the side wall, or vertical through the roof.

CFM Corporation does not require any opening for inspection of vent pipe.

Only CFM Corporation and Simpson DuraVent vent- ing components specifically approved and labelled for this stove may be used.

Minimum clearances between vent pipes and com- bustible materials is one (1”) inch (25 mm), except where stated otherwise.

Venting terminals shall not be recessed into a wall or siding.

Horizontal venting must be installed on a level plane without an inclining or declining slope.

There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24” from the front of the termination hood.

Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent termi- nation area after snow falls, and clear to prevent ac- cidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.

Location of Vent Termination

It is imperative the vent termination be located observ- ing the minimum clearances as shown on this page.

10

20012734

Image 10
Contents Stardance Direct Vent/Natural Vent Gas Heater Table of Contents General Information Installation Requirements Gas Equipment Venting System not ProvidedStardance Direct Vent / Natural Vent Dimensions Stardance dimensionsMaterials Clearance RequirementsMinimum Clearances to Combustible Locating the StoveHearth Requirements Wall Centerline from FloorWall and Ceiling Clearances Direct Vent OnlyHigh Elevations Gas SpecificationsGas Inlet and Manifold Pressures Horizontal Termination Direct Vent onlyRestrictor Plate is used on Direct Vent Installations Only Restrictor Plate Adjustment For Extended Pipe RunsRestrictor Plate Adjustment Examples for Extended Run/Restrictor Plate SettingsLocation of Vent Termination Vent Termination ClearancesDirect Vent Only Canadian Installations1 US Installations2 General Venting Information Termination LocationVenting Requirements Natural Vent Only Termination ClearancesSimpson DuraVent Components Venting Requirements and Options Direct Vent onlyApproved Vent System Components Minimum Horizontal Vent Kit 2792CFM Vent Components Install the Optional Fan Remove rear skirt insertInstall the Vent Adapter Pipe Venting System Assemlby Direct Vent General InformationSide Wall Termination Assembly Install Vent Adapter PipeSelkirk Corporation Vent Components Assemble the wall sleeve and firestop Vertical Through the Roof Vent Assembly Vent Termination Below GradeSelkirk Direct-Temp Metalbestos Direct Vent System Inlet End Outlet End To Termination Vertical VentingHorizontal Venting To ApplianceOffsets Adjustable Length AJSupporting DIRECT-TEMP Vertical Support Supporting DIRECT-TEMP Horizontal SupportBelow grade installation Vertical Installation Fig Venting System Assembly Natural Vent General Information Minimum Height Above Roof RequirementsInstall the Vent Pipe Install the Log SetStardance Direct Vent/Natural Vent Gas Heater Connect the Gas Supply Line Install ON/OFF SwitchBurner Information Thermostat Connection optional Install the Front PlateOperation Your First FireSddvt Series Flame & Temperature AdjustmentFlame Characteristics Sddvtc Series Comfort Control ModelsEuro SIT Lighting and Operating InstructionsTo Turn Off Gas To Heater HoneywellTroubleshooting the Gas Control System Sddvt Series SIT Nova 820 Millivolt ValveOn Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Delay Timer ModeChange Between F/C Temperature Units Auto ModeFan Override During Auto Mode Disable Thermostat FunctionLocal Path On PathAuto Path Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Valve Conversion Sddvt Series ModelsPilot Type Pilot Orifice ConversionValve All Models Burner Orifice ConversionBottom View Conversion to LP Input BTU/h Injector Orifice Size MatrixConversion to Natural Gas Input BTU/h Cleaning the Glass MaintenanceLogset and Burner Cleaning and Inspection Glass ReplacementInspect the Vent System Annually Gasket ReplacementStove Disassembly Check the Gas Flame RegularlyOptional Thermostat Wiring Wiring DiagramsOn/Off Switch Wiring Schematic DiagramStardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater DescriptionFuel Conversion Kits Optional Accessories Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Stardance Direct Vent/Natural Vent Gas Heater Limited Lifetime Warranty CFM Corporation

SDDVT specifications

Vermont Casting's SDDVT, or the Signature Series Direct Vent Technology, represents a remarkable blend of design, efficiency, and functionality in the world of high-performance heating appliances. Known for its commitment to craftsmanship, Vermont Casting has long been synonymous with quality, and the SDDVT is no exception.

One of the standout features of the SDDVT is its advanced direct venting capability. This system allows for efficient venting of combustion gases directly outside, minimizing the risk of backdrafting and ensuring optimal indoor air quality. It draws air from the outside for combustion, creating a more controlled environment that enhances both efficiency and safety. Homeowners can rest easy knowing that the SDDVT provides a reliable heating solution while protecting indoor air quality.

Another significant aspect of the SDDVT is its high-efficiency performance. With an impressive Annual Fuel Utilization Efficiency (AFUE) rating, the SDDVT maximizes heat output while minimizing fuel consumption. This efficiency translates to lower energy bills and a reduced carbon footprint, making it an environmentally friendly choice for heating. The unit is designed to operate effectively even in extremely cold temperatures, ensuring comfort throughout the winter months.

The SDDVT also boasts an array of customizable options that appeal to a wide range of aesthetic preferences. Available in various finishes and styles, including traditional cast iron and sleek modern designs, homeowners can select a model that complements their decor. The unit features a large viewing glass that provides an unobstructed view of the flames, creating a cozy ambiance that enhances the living space.

Incorporating cutting-edge technology, the SDDVT includes electronic ignition and advanced control systems, allowing users to easily manage their heating preferences. The integration of smart technology enables compatibility with home automation systems, giving users added convenience and control.

Overall, Vermont Casting's SDDVT is an exemplary heating solution characterized by its innovative direct venting technology, high efficiency, and customizable design options. With a focus on quality and performance, this unit exemplifies the brand's dedication to providing sustainable and effective heating solutions tailored to modern living. Whether for new construction or retrofitting existing spaces, the SDDVT stands as a premier choice for comfort and style.