1/2” Gas Supply
1/2” NPT X 1/2” Flare
3/8” Flex Line
(From Valve)
FP297a
Fig. 5 Gas shutoff valve and flex connector.
When using copper or flex connector, use only ap- proved fittings. Always provide a union when using black iron pipe so that the gas line can be easily discon- nected for burner or fan servicing. Refer to the gas specification for pressure details and ratings.
Isolate or disconnect this or any other gas appli- ance control from the gas line when pressure test- ing.
DO NOT subject the fireplace valve to test pressures exceeding 1/2 psi.
EB-1 Electrical Junction Box Connection
The fireplace, when installed, must be electrically connected and grounded in ac- cordance with local codes; in the absence of local codes, use the current CSA C22.1 Canadian Electrical Code.
For USA installations, follow the local codes and National Electrical Code ANSI/ NFPA No. 70.
It is strongly suggested the wiring of the
Ensure power to the supply line has been disconnected before commencing with this procedure.
The
To connect the
1.Remove the front cover of the
2.Remove the plug socket assembly from the
3.Feed the supply line in from the out through the elec- trical knockout.
4.Connect the ground wire of the supply line to the green screw of the socket assembly.
5.Connect the white wire of the power line to the chrome screw of the socket assembly.
6.Connect the black wire of the power supply line to the brass screw (polarized) of the socket assembly.
360DVS Series Direct Vent Fireplaces
7.Refit the socket assembly back into the electrical box and replace the cover plate.
8.The
Electrical
Inlet Hole
Gas Inlet
Hole
| |
| ing on the specific model, |
| this box may be installed on |
FP1428 | either side of the appliance. |
|
Fig. 6 EB-1 attachment.
Remote ON/OFF Switch Installation
Do not wire the remote ON/OFF wall switch for this gas appliance into a 120V power supply.
1.Thread the wiring through the holes on the end panels of the appliance. Take care not to cut the wire or insulation on metal edges. Route the wire to a conveniently located receptacle box.
2.Attach the wire to the ON/OFF switch and install the switch into the receptacle box.
3.Connect the other ends of the wire to the gas control valve, as shown in Figure 7.
Remote ON/OFF Switch
TP Gas
Control
TH Valve
TP
TH
FP1429
Fig. 7 Remote switch wiring diagram for R models.
Alternate Switch Location
The remote switch can be installed on the front or the side of the access door. Simply mount the switch to the bracket provided and screw the bracket to either side of the frame, lining up the screws with the prepunched holes. (Fig. 8)
10006326 | 11 |