Majestic Appliances 360DVS2, 360DVSR, 360DVSL SIT 822 Valve with a Honeywell Electronic Igniter

Page 31

360DVS Series Direct Vent Fireplaces

Troubleshooting the Gas Control System

SIT 822 Valve with a Honeywell Electronic Igniter

START

NOTE: Remove glass before servicing.

 

TURN GAS SUPPLY OFF. NO

TURN ON/OFF SWITCH

TO CALL FOR HEAT.

POWER TO MODULE?

(24V NORMAL)

YES

SPARK ACROSS NO IGNITOR SENSOR GAP?

YES

CHECK: LINE VOLTAGE (120VAC).

LOW VOLTAGE TRANSFORMER (19.5 MINIMUM VAC).

ON/OFF SWITCH. WIRING CONNECTIONS.

UNPLUG IGNITION LEAD

AND CHECK SPARK

AT MODULE

(24VAC NORMAL).

NO

 

SPARK OK?

REPLACE MODULE.

 

YES

CHECK IGNITION CABLE GROUND WIRING, CERAMIC INSULATOR, AND GAP. CORRECT AS NECESSARY.

CHECK BOOT OF IGNITION CABLE FOR SIGNS OF MELTING OR BUCKLING. TAKE PROTECTIVE ACTION TO SHIELD CABLE AND BOOT FROM EXCESSIVE TEMPERATURES.

TURN GAS ON.

NO

CHECK THAT ALL MANUAL GAS VALVES ARE OPEN, SUPPLY TUBING

 

 

 

PILOT BURNER LIGHTS?

 

AND PRESSURES ARE GOOD, AND PILOT BURNER ORIFICE IS NOT

YES

 

 

BLOCKED.

 

 

 

 

CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND PILOT

 

 

 

OPERATOR ON GAS CONTROL.

 

 

 

CHECK FOR 24VAC ACROSS PV-MVPV TERMINALS ON MODULE. IF

 

 

 

VOLTAGE IS OKAY, REPLACE GAS CONTROL IF NOT, REPLACE MODULE.

 

 

 

 

SPARK STOPS WHEN

NO

NOTE: IF S8600B GOES INTO LOCKOUT, RESET SYSTEM.

 

 

PILOT IS LIT?

 

 

CHECK CONTINUITY OF IGNITION CABLE AND GROUND WIRE.

YES

 

 

 

CLEAN FLAME ROD.

 

 

 

 

CHECK ELECTRICAL CONNECTIONS BETWEEN FLAME ROD & MODULE.

 

 

 

 

CHECK FOR CRACKED CERAMIC FLAME ROD INSULATOR.

 

 

 

 

CHECK THAT PILOT FLAME COVERS FLAME ROD AND IS STEADY BLUE.

 

 

 

 

ADJUST PILOT FLAME.

 

 

 

 

IF PROBLEM PERSISTS, REPLACE MODULE.

 

 

 

 

 

NO

MAIN BURNER LIGHTS?

YES

SYSTEM RUNS UNTIL NO ON/OFF SWITCH IS IN

"OFF" POSITION? YES

TROUBLESHOOTING

ENDS.

CHECK FOR 24VAC ACROSS MV-MVPV TERMINALS. IF NO VOLTAGE, REPLACE MODULE.

CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND GAS CONTROL. IF OKAY, REPLACE GAS CONTROL OR GAS CONTROL OPERATOR.

NOTE: IF S8600B GOES INTO LOCKOUT, RESET SYSTEM.

CHECK FOR CONTINUITY OF IGNITION CABLE AND GROUND WIRE. NOTE: IF GROUND IS POOR OR ERRATIC, SHUTDOWN MAY OCCUR OCCASIONALLY EVEN THOUGH OPERATION IS NORMAL AT THE TIME OF CHECKOUT.

CHECK THAT THE PILOT FLAME COVERS FLAME ROD AND IS STEADY AND BLUE.

IF CHECKS ARE OKAY, REPLACE MODULE.

10006326

31

Image 31
Contents 360DVSL 360DVSR Table of Contents Ansi Z21.88-2005 / CSA Vented Gas Fireplace Heaters Installation & Operating InstructionsPlease Review the Following Carefully Gas Equipment Venting System not Provided Clear of ALL ObstructionsRear Vent Configuration Fireplace Dimensions 360DVS2Top Vent Configuration Fireplace Dimensions 360DVS3 / 306DVSL / 360DVSR Rear Vent Configuration Top Vent Configuration Framing Dimensions 360DVS2Rear Vent Configuration360DVSL/R Framing Dimensions 360DVS3 / 360DVSL / 360DVSRRear Vent Confiration Rear Vent Configuration Top Vent Configuration Model 360DVS3Clearance to Combustibles Locating Your FireplaceMantels Final Finishing Gas Line InstallationHearth Framing & FinishingAlternate Switch Location Remote ON/OFF Switch InstallationEB-1 Electrical Junction Box Connection Remove screws from outer collar adapter Optional Top Vent ApplicationLocation of Vent Termination General VentingElectronic Gas Control Valve There must not be any obstruction such as bushesGeneral Venting Information Termination Location Canadian Installations1 US Installations2Twist Lock Pipes Canadian InstallationsUSA Installations General Information Assembling Vent PipesStep How to Use the Vent GraphRear Wall Installation Rear Wall ApplicationVent Opening for Noncombustible Wall Vertical Sidewall ApplicationZero clearance sleeve is required only for combustible walls Vertical Side Wall InstallationVertical height requirement Always install horizontal venting on a level planeHorizontal runs if the vertical exceeds 24 610 mm Below Grade InstallationMaximum termination to roof clearance Chimney support Vertical Through-the-Roof InstallationTwist Lock Venting Components Glass Information Window Frame Assembly RemovalFront Window Frame Assembly Operating InstructionsCeramic Refractory Installation Glass CleaningLog Installation Place this lava rock material on burner tiles Lava Rock and Ember Material PlacementFlame & Temperature Adjustment Ember Material Pt. #51915Flame adjustment knob for SIT valve Flame CharacteristicsWhat to do if YOU Smell GAS Lighting and Operating InstructionsLighting Instructions To Turn OFF Gas to HeaterTurning Off the Gas to the Appliance SIT Nova 820 Millivolt Valve Troubleshooting the Gas Control SystemSIT 822 Valve with a Honeywell Electronic Igniter Check Troubleshooting Honeywell VS8421Start YESSIT 820 Nova Gas Control Valve Fig Fuel Conversion InstructionsSIT Top Convertible Pilot PSE PilotHoneywell Gas Control Valve Fig Honeywell conversion screw replacementBurner and Burner Compartment MaintenanceCleaning Standing Pilot Control System Cleaning Electronic Ignition System360DVS Series 360DVSL 360DVSR DVS Series Direct Vent Fireplaces Fan Kits Optional AccessoriesModel Functions Controlled Remote ControlsWiring Instructions Decorative Trim Frame Kit360DVS Series Direct Vent Fireplaces DVS Series Direct Vent Fireplaces If Warranty Service is NEEDED… Product Covered by this WarrantyAFUE% Efficiency Ratings

360DVS3, 360DVS2, 360DVSR, 360DVSL specifications

Majestic Appliances has been a leader in the home appliance industry, and their latest creations, the 360DVSL, 360DVS2, 360DVS3, and 360DVSR, exhibit the company's commitment to innovation, quality, and user convenience. These models are built with cutting-edge technology and unique features designed to enhance the cooking experience.

The Majestic 360DVSL is known for its sleek design and advanced cooking capabilities. One of its standout features is the dual-fuel capability, which combines the benefits of both gas and electric cooking. This allows for precise temperature control while retaining the intense heat that gas provides. The 360DVSL also features a large oven capacity, making it particularly useful for families and those who love to entertain. The self-cleaning function simplifies maintenance, allowing users to spend more time cooking and less time cleaning.

The 360DVS2 model takes efficiency to the next level with its smart technology integration. It comes equipped with Wi-Fi connectivity, enabling users to control the oven remotely via a smartphone app. This feature not only allows for pre-heating but also for monitoring cooking progress from anywhere in the house. Additionally, the 360DVS2 includes a convection oven that distributes heat evenly, ensuring perfect baking every time.

Meanwhile, the 360DVS3 model caters to culinary enthusiasts with its professional-grade features, including high BTU burners that can achieve rapid boiling and simmering. This model’s heavy-duty construction means it can withstand heavy use, making it ideal for serious cooks. The integrated griddle and customizable burner configurations provide maximum flexibility for diverse cooking needs.

Lastly, the 360DVSR is designed with safety and usability in mind. It features a child lock function and advanced flame failure safety systems, providing peace of mind for households with children. Moreover, the ergonomic knobs and touch controls enhance usability, allowing precise adjustments even when hands are busy.

Overall, the Majestic Appliances range of 360DVSL, 360DVS2, 360DVS3, and 360DVSR offers a comprehensive selection tailored to meet a variety of cooking needs. Each model is imbued with the spirit of innovation, quality craftsmanship, and attention to detail that Majestic is known for, making them excellent choices for anyone looking to upgrade their kitchen appliances.