Majestic Appliances 360DVS2 Maintenance, Cleaning Standing Pilot Control System, Brass Trim

Page 35

360DVS Series Direct Vent Fireplaces

Maintenance

Burner and Burner Compartment

It is important to keep the burner and the burner com- partment clean. At least once per year remove the logs and lava rock/ember material. Vacuum and wipe out the burner compartment. Remove and refit the logs per the instructions in this manual.

Always handle the logs with care as they are fragile and may also be hot if the fire-

place has been in use. FK24/FK12 Fan Assembly

The fan unit requires periodic cleaning. At least once per month in the operating season, open the lower lou- vre panels and wipe or vacuum the area around the fan to remove any build up of dust or lint.

Brass Trim

Clean the brass trim pieces using a soft cloth lightly dampened with lemon oil. Do not use water or house- hold cleaners on any brass components.

Cleaning the

Standing Pilot Control System

The burner and control system consists of:

burner tube

gas orifice

pilot assembly

thermopile

millivolt gas valve

 

 

Most of these components may require only an occa- sional checkup and cleaning and some may require ad- justment. If repair is necessary, it should be performed by a qualified technician.

1.Turn off pilot light at gas valve side.

2.Let fireplace cool if it has been running.

3.Remove window frame assembly. (Refer to Window Frame Assembly Removal section)

4.Remove logs.

5.Vacuum burner compartment especially around orifice primary air openings.

6.Visually inspect pilot. Brush or blow away any dust or lint accumulation.

7.Reinstall logs.

8.Ignite pilot; refer to Lighting Instructions.

9.Reinstall window frame assembly.

To obtain proper operation, it is imperative that the pilot and burner’s flame characteristics are steady, not lifting or floating.

Typically, the top 3/8 – 1/2” (10 – 13 mm) of the thermo- pile should be engulfed in the pilot flame. (Page 26, Fig. 46)

To adjust pilot burner (to be done by a qualified service technician):

1.Remove pilot adjustment cap.

2.Adjust pilot screw to provide properly sized flame.

3.Replace pilot adjustment cap.

The primary air shutter is set at factory and should be adjusted, if necessary, only by a qualified service tech- nician.

Cleaning Electronic Ignition System

The Electronic Ignition burner/control system consists of:

main burner

gas orifice

pilot burner

24VAC valve with transformer

The process for taking care of Electronic Ignition units is identical to that for taking care of Standing Pilot models.

10006326

35

Image 35
Contents 360DVSL 360DVSR Table of Contents Please Review the Following Carefully Installation & Operating InstructionsAnsi Z21.88-2005 / CSA Vented Gas Fireplace Heaters Gas Equipment Venting System not Provided Clear of ALL ObstructionsTop Vent Configuration Fireplace Dimensions 360DVS2Rear Vent Configuration Fireplace Dimensions 360DVS3 / 306DVSL / 360DVSR Rear Vent Configuration Top Vent Configuration Framing Dimensions 360DVS2Rear Vent Configuration360DVSL/R Framing Dimensions 360DVS3 / 360DVSL / 360DVSRRear Vent Confiration Rear Vent Configuration Top Vent Configuration Model 360DVS3Mantels Locating Your FireplaceClearance to Combustibles Final Finishing Gas Line InstallationHearth Framing & FinishingEB-1 Electrical Junction Box Connection Remote ON/OFF Switch InstallationAlternate Switch Location Remove screws from outer collar adapter Optional Top Vent ApplicationLocation of Vent Termination General VentingElectronic Gas Control Valve There must not be any obstruction such as bushesGeneral Venting Information Termination Location Canadian Installations1 US Installations2Twist Lock Pipes Canadian InstallationsUSA Installations General Information Assembling Vent PipesStep How to Use the Vent GraphRear Wall Installation Rear Wall ApplicationVent Opening for Noncombustible Wall Vertical Sidewall ApplicationZero clearance sleeve is required only for combustible walls Vertical Side Wall InstallationVertical height requirement Always install horizontal venting on a level planeHorizontal runs if the vertical exceeds 24 610 mm Below Grade InstallationMaximum termination to roof clearance Chimney support Vertical Through-the-Roof InstallationTwist Lock Venting Components Glass Information Window Frame Assembly RemovalFront Window Frame Assembly Operating InstructionsLog Installation Glass CleaningCeramic Refractory Installation Place this lava rock material on burner tiles Lava Rock and Ember Material PlacementFlame & Temperature Adjustment Ember Material Pt. #51915Flame adjustment knob for SIT valve Flame CharacteristicsWhat to do if YOU Smell GAS Lighting and Operating InstructionsLighting Instructions To Turn OFF Gas to HeaterTurning Off the Gas to the Appliance SIT Nova 820 Millivolt Valve Troubleshooting the Gas Control SystemSIT 822 Valve with a Honeywell Electronic Igniter Check Troubleshooting Honeywell VS8421 Start YESSIT 820 Nova Gas Control Valve Fig Fuel Conversion InstructionsSIT Top Convertible Pilot PSE PilotHoneywell Gas Control Valve Fig Honeywell conversion screw replacementBurner and Burner Compartment MaintenanceCleaning Standing Pilot Control System Cleaning Electronic Ignition System360DVS Series 360DVSL 360DVSR DVS Series Direct Vent Fireplaces Fan Kits Optional AccessoriesModel Functions Controlled Remote ControlsWiring Instructions Decorative Trim Frame Kit360DVS Series Direct Vent Fireplaces DVS Series Direct Vent Fireplaces If Warranty Service is NEEDED… Product Covered by this WarrantyAFUE% Efficiency Ratings