Jotul GF 200 DV manual Maintenance, Glass Front, Glass and Gasket Replacement

Page 23

Maintenance

The GF 200 DV Lillehamer gas stove and its venting system should be inspected before use and at least annually by a qualified service technician.

IMPORTANT:

ALWAYS TURN OFF THE GAS SUPPLY TO THE STOVE BEFORE ANY SERVICE WORK IS PERFORMED ON THE STOVE.

General cleaning: The firebox should be vacuumed out annually to remove any surface build up. Be sure to vacuum or wipe off the pilot assembly and burner orifice and burner tube. Also, when vacu- uming the log set, be sure to handle it carefully as it is very fragile.

Gasket inspection: It is important that the glass gasket be inspected at least annually. Examine the rope gasket for signs of deterioration and make sure the gasket has a positive seal. This is impor- tant to prevent combustion gases from escaping into the room. Replace the gasket if necessary, refer to the replacement parts list on page 25.

Always replace any damaged or broken parts with JØTUL AUTHORIZED PARTS ONLY. These are available through your Jøtul dealer. Never use any substitute parts on your Lillehammer Direct Vent stove.

With proper care and maintenance, your Jøtul gas stove will provide you with many years of service. If you experience any problems with Jøtul GF 200 DV, contact your authorized Jøtul dealer for assistance.

Fill out the Maintenance Record form on the next page and keep it up to date. It will provide useful information of service activity to help you and your dealer keep your stove in top condition.

Glass Front

Do not operate the Lillehammer gas stove with the glass front removed, cracked or broken. Replace- ment of the glass should be done by a licensed or qualified service person. Only remove glass for routine service. Always handle glass carefully.

Glass and Gasket Replacement

1.Using a nail punch inserted into the perf holes, carefully pry the two glass retainer tabs back. See fig. 27.

2.Peel away all remnants of the old gasket material and clean any adhesive residue off the glass.

3.Peel the paper backing off the replacement gasket to expose the adhesive.

4.Apply the gasket to the panel, wrapping the adhesive side down around the panel edge. See fig. 28.

5.Insert the gasketed glass panel into the frame and use the nail punch to bend the retainer tabs over the edge.

Bend Tab back

Figure 27. Glass removal.

RETAIN THIS MANUAL FOR REFERENCE

AND MAKE IT AVAILABLE TO ANYONE

USING OR SERVICING THE STOVE.

WARNING: OBSERVE CAUTION NEAR THE

GLASS. THE GLASS PANEL MAY SHATTER

UNEXPECTEDLY IF STRUCK WITH AN

OBJECT. ALWAYS HANDLE THE GLASS

PANEL WITH CARE. WHEN SERVICING THE

STOVE ALWAYS PULL THE GLASS ASSEM-

BLY STRAIGHT UP FOR REMOVAL.

Figure 28. Glass gasket replacement.

23

Image 23
Contents GF 200 DV Lillehammer Gas Heater Welcome to Jøtul Table of Contents Input Rates GF 200 DV Lillehammer OptionsGlass Panel General InformationMinimum Safety InformationLocating the Stove Hearth RequirementsClearance to Combustibles Vent Restriction Install the Exhaust Restrictor PlateInstall the Air Inlet Restrictor Plate Venting RequirementsMinimum Vertical Rise =1 ft For a Vertical Venting RequirementsSimpson Dura-Vent Ceiling Firestop #943 is required These guidelines must be followed Co-linear Hearthmount InstallationNot Vent TWO Appliances Into a Single Chimney Masonry or Prefabricated Chimney ConversionHorizontal Venting Horizontal Termination Horizontal vent with two elbows Wall Shield InstallationVent Terminal Clearances National Fuel Gas Code Vent Termination RequirementsCanadian Requirements Mobile Home InstallationFuel Conversion Kit Contents Gas ConversionAir Shutter adjustment and Burner Orifice Gas Conversion ProcedureConnect the Gas Supply Regulator AssemblyRequired Manifold Pressure in. W.C Gas PressureLeak Test Required Inlet Gas Pressures in. W.CCanadian Requirements High Altitude AdjustmentDerating Procedure RequirementsAir Shutter Settings See Figure Install the Log SetChecking the System Remote ControlCorrect flame picture Operation of ApplianceGlass Front MaintenanceGlass and Gasket Replacement Model Maintenance RecordGF 200 DV Lillehammer Illustrated Parts ListMatte Black Blue Black Ivory Forest Green Painted & Enamelled Cast Iron PartsToOFF. Do not force Access the lower controlsNormal service Jøtul North America Jøtul ASA