Installing the Optional Wall Thermostat of Remote Control
When installing a wall mounted thermostat to the Lillehammer, it must be 750 millivolt DC
The thermostat should be connected to the Lillehammer using a minimum of 16 gauge wire with a maximum length of 35 feet of wire.
Connect the two thermostat wire leads to the two lower terminals on the terminal block located directly above the ignitor button. Do not over- tighten the connections. IT IS NOT NECESSARY TO DISCONNNECT ANY OTHER WIRES. See Figure 24.
For the thermostat to work, the
At the thermostat the two wires should be connected to the two connections screws on the thermostat base plate per the manufacturers instructions.
CAUTION:
LABEL ALL WIRES PRIOR TO DISCON- NECTION WHEN SERVICING THE CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. ALWAYS VERIFY PROPER OPERATION AFTER SERVICING THE APPLIANCE.
Checking the System
1.Purging the Gas Line: When lighting the appli- ance for the first time it will take a few mo- ments to clear the gas line of air. Once this purge is complete, the appliance will operate as described in the lighting instructions located on the stove’s rating plate. All subsequent lightings of the stove will not require such purging of the gas line.
2.Pilot Flame: The pilot flame should be steady, not lifting or floating. The flame should be blue in color around the pilot hood, with traces of yellow toward the outer edges.
It is imperative that the pilot flame engulf the top 3/8” of the thermopile(power generator) and the top 1/8” of the quick drop out thermocouple. The pilot flame should project out of the pilot hood 1” at all three ports. See Figure 25.
THERMOPILE
TH
TP
TH
TP
VALVE
TERMINAL
BLOCK
ROCKER
SWITCH
ON
OFF
STAT
OPTIONAL
THERMOSTAT
or
REMOTE
CONTROL
Burner Tube
Pilot
Assembly
Figure 24. Thermostat / Remote Control Wiring Diagram.
Remote Control
When using a remote, the remote receiver should be wired to the terminal block the same way the thermostat would be. See the instructions above.
Ignitor
1/8”
(3mm)
Min.
Thermocouple
1” |
|
(25mm) | 3/8” |
| |
| (8mm) |
| Min. |
Thermopile
Figure 25. Pilot Location and Correct Appearance
21