Jotul GF 200 DV manual Wall Shield Installation, Horizontal vent with two elbows

Page 13

OPTION # 4

Simpson Dura-Vent 45

Degree Elbow #945

Simpson Dura-Vent

14” Snorkel #982

12” (300 mm) and 6” (150 mm) Max. Horizontal Run

into a 14” Snorkel

Both Draft Restrictors Required

OPTION # 5

 

Simpson Dura-Vent

 

Horizontal Termination

 

 

 

6” (150 mm)

Cap #984 or #985

 

 

 

Simpson Dura-Vent

 

#908B

 

 

 

18” Max.

 

 

460 mm

 

 

Two 90 Degree

 

 

Elbows

Figure 12-4. Maximum horizontal run with single elbow to a snorkel termination.

OPTION # 5

 

Simpson Dura-

Two Simpson

Vent Horizontal

Square

Dura-Vent 90

Termination

Degree Elbows

#984

#990B

 

 

Simpson Dura-Vent Wall

 

Thimble Cover #940

Figure 12-5. Horizontal vent with two elbows.

21/2

12 ” 64mm

305 3” mm 76mm

Figure 12-5a. Horizontal vent with two elbows.

Figure 13. Termination clearances to exterior overhangs.

Wall Shield Installation

When horizontally venting directly off the rear of the stove, install the decorative Wall Shield #129349, (included in the stove), to cover the top of the venting hole in the wall. See Figure 14.

1.Remove the top four 1/4” hex head screw from the rear shroud of the stove.

2.Align the holes in the wall shield with the holes in the rear shroud.

3.Secure the wall shield to the stove with the four 1/4” hex head screws.

Wall Shield

Rear

Shroud

Figure 14. Install the Wall Shield.

13

Image 13
Contents GF 200 DV Lillehammer Gas Heater Welcome to Jøtul Table of Contents Input Rates GF 200 DV Lillehammer OptionsGlass Panel General InformationLocating the Stove Safety InformationHearth Requirements MinimumClearance to Combustibles Install the Air Inlet Restrictor Plate Install the Exhaust Restrictor PlateVenting Requirements Vent RestrictionSimpson Dura-Vent Ceiling Firestop #943 is required Vertical Venting RequirementsMinimum Vertical Rise =1 ft For a These guidelines must be followed Co-linear Hearthmount InstallationNot Vent TWO Appliances Into a Single Chimney Masonry or Prefabricated Chimney ConversionHorizontal Venting Horizontal Termination Horizontal vent with two elbows Wall Shield InstallationVent Terminal Clearances National Fuel Gas Code Vent Termination RequirementsFuel Conversion Kit Contents Mobile Home InstallationGas Conversion Canadian RequirementsAir Shutter adjustment and Burner Orifice Gas Conversion ProcedureConnect the Gas Supply Regulator AssemblyLeak Test Gas PressureRequired Inlet Gas Pressures in. W.C Required Manifold Pressure in. W.CDerating Procedure High Altitude AdjustmentRequirements Canadian RequirementsAir Shutter Settings See Figure Install the Log SetChecking the System Remote ControlCorrect flame picture Operation of ApplianceGlass and Gasket Replacement MaintenanceGlass Front Model Maintenance RecordGF 200 DV Lillehammer Illustrated Parts ListMatte Black Blue Black Ivory Forest Green Painted & Enamelled Cast Iron PartsNormal service Access the lower controlsToOFF. Do not force Jøtul North America Jøtul ASA