Horizontal Venting (Horizontal Termination)

The maximum horizontal run made directly off the rear of the stove into a standard horizontal cap (#984 or #985) must be no more than a 9” section of Simpson Dura-vent (#907B). See Figure 12-1.

The maximum horizontal run made directly off the rear of the stove into a 14” snorkel cap (#982) must be no more than a 24” section of Simpson Dura-vent (#904). See Figure12-3.

The horizontal termination cap must maintain a 3" clearance (80 mm) to any overhead combus- tible projections 2 1/2" (60 mm) or less. Maintain 12" (300 mm) clearance from projections exceed- ing 2 1/2". See Figure 13.

Any horizontal run of vent must be level or have a 1/4" (5 mm) rise for every foot (300 mm) of run toward the termination cap. DO NOT ALLOW THE VENT TO RUN DOWNWARD, AS THIS CAN CAUSE HIGH TEMPERATURES AND THE POSSIBILITY OF A FIRE.

A 1” (26 mm) clearance must be maintained around all co-axial vent pipe.

For buildings with vinyl siding, a Vinyl Siding Standoff should be installed between the vent cap and the exterior wall (Simpson Dura-Vent #950). The Standoff prevents exposure of the vinyl siding to excessive heat that can damage the siding material.

A 10" X 10" (250 mm x 250 mm) square hole is required to maintain proper vent clearances through a combustible wall. Simpson Dura-Vent Wall Thimble #942 installed according to the manufacturer’s instructions meets clearance requirements.

DO NOT FILL AIR SPACE WITH ANY TYPE OF INSULATION.

Do not recess the termination cap into the exterior wall or siding.

OPTION # 1

 

 

 

 

10” Max.

 

 

 

250 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Simpson Dura-Vent

Horizontal Termination

Cap #984 or #985

9” (230 mm) Max. Horizontal Simpson Dura-Vent #907B No Draft Restriction Required

Figure 12-1. Maximum horizontal run to rear termination.

OPTION # 2

 

 

 

 

 

5” Max.

 

 

 

 

 

 

 

 

 

 

130 mm

 

 

 

 

 

 

 

 

 

 

 

Simpson Dura-Vent

Horizontal Termination

Cap #984 or #985

6” (150 mm) Min. Horizontal Simpson Dura-Vent #908B No Draft Restriction Required

Figure 12-2. Minimum horizontal run to rear termination.

OPTION # 3

Simpson Dura-Vent

 

14” Snorkel

 

Termination #982

24” (610 mm) Max. Horizontal Run into 14” Snorkel,

Simpson Dura-Vent #904

Both Draft Restrictors Required

Figure 12-3. Maximum horizontal run to a snorkel termination.

IMPORTANT:

FOLLOW THE INSTALLATION IN-

STRUCTIONS PROVIDED WITH EACH SIMPSON DURA-VENT COMPONENT.

12

Image 12
Contents GF 200 DV Lillehammer Gas Heater Welcome to Jøtul Table of Contents GF 200 DV Lillehammer Options Input RatesGeneral Information Glass PanelSafety Information Locating the StoveHearth Requirements MinimumClearance to Combustibles Install the Exhaust Restrictor Plate Install the Air Inlet Restrictor PlateVenting Requirements Vent RestrictionVertical Venting Requirements Simpson Dura-Vent Ceiling Firestop #943 is requiredMinimum Vertical Rise =1 ft For a Co-linear Hearthmount Installation These guidelines must be followedMasonry or Prefabricated Chimney Conversion Not Vent TWO Appliances Into a Single ChimneyHorizontal Venting Horizontal Termination Wall Shield Installation Horizontal vent with two elbowsVent Termination Requirements Vent Terminal Clearances National Fuel Gas CodeMobile Home Installation Fuel Conversion Kit ContentsGas Conversion Canadian RequirementsGas Conversion Procedure Air Shutter adjustment and Burner OrificeRegulator Assembly Connect the Gas SupplyGas Pressure Leak TestRequired Inlet Gas Pressures in. W.C Required Manifold Pressure in. W.CHigh Altitude Adjustment Derating ProcedureRequirements Canadian RequirementsInstall the Log Set Air Shutter Settings See FigureRemote Control Checking the SystemOperation of Appliance Correct flame pictureMaintenance Glass and Gasket ReplacementGlass Front Maintenance Record ModelIllustrated Parts List GF 200 DV LillehammerPainted & Enamelled Cast Iron Parts Matte Black Blue Black Ivory Forest GreenAccess the lower controls Normal serviceToOFF. Do not force Jøtul ASA Jøtul North America