￿THIS HEATER MUST BE INSTALLED AND MAIN- TAINED BY A QUALIFIED SERVICE AGENCY.

￿THIS APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY OR FLUE SERVING ANY OTHER APPLI- ANCE.

￿The installation and repair of this appliance must be done by a qualified service person. Failure to properly install and maintain this heater could result in an unsafe or hazardous installation, which may result in a fire, explosion, property damage, personal injury or loss of life.

￿This appliance should be inspected before use and at least annually. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean.

￿The installation must conform to local codes. Your local Jøtul dealer can assist you in determining what is required in your area for a safe and legal installation. Some areas require a permit to install a gas burning appliance. Always consult your local building inspector, or authority having jurisdiction, to determine what regulations apply in your area.

￿REMEMBER: Your local officials have final author- ity in determining if a proposed installation is acceptable. Any requirement that is requested by the local authority having jurisdiction, that is not specifically addressed in THIS manual, defaults to local code. In the absence of local codes, the installation requirements must comply with the current National codes. In the U.S., these require- ments are established in the National Fuel Code, ANSI Z223.1.(NFPA 54). In Canada, the codes have been established in CAN/CGA B149 Fuel Installa- tion Code.

￿Installer l’appareil selon les codes ou reglements locaux, ou, en l’absence de tels reglements, selon les Codes d’installation CAN/CGA-B149.

￿DO NOT OPERATE THIS STOVE IF ANY PART HAS BEEN UNDER WATER. Call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which may have been under water.

￿Ne pas se servir de cet appareil s’il a ete’ plonge dans l’eau, completement ou en partie. Appeler un technicien qualifie pour inspecter l’appareil et remplacer toute partie du syste’me de controle et toute commande qui ont ete plonges dans l’eau.

Glass Panel

DO NOT OPERATE THE LILLEHAMMER GAS STOVE WITH THE GLASS FRONT REMOVED, CRACKED OR BROKEN.

REPLACEMENT OF THE GLASS SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON. ONLY REMOVE GLASS FOR ROUTINE SERVICE. ALWAYS HANDLE GLASS CAREFULLY.

SEE THE MAINTENANCE CHAPTER FOR INSTRUCTIONS ON REPLACING THE GLASS PANEL.

5

Image 5
Contents GF 200 DV Lillehammer Gas Heater Welcome to Jøtul Table of Contents Input Rates GF 200 DV Lillehammer OptionsGlass Panel General InformationLocating the Stove Safety InformationHearth Requirements MinimumClearance to Combustibles Install the Air Inlet Restrictor Plate Install the Exhaust Restrictor PlateVenting Requirements Vent RestrictionMinimum Vertical Rise =1 ft For a Vertical Venting RequirementsSimpson Dura-Vent Ceiling Firestop #943 is required These guidelines must be followed Co-linear Hearthmount InstallationNot Vent TWO Appliances Into a Single Chimney Masonry or Prefabricated Chimney ConversionHorizontal Venting Horizontal Termination Horizontal vent with two elbows Wall Shield InstallationVent Terminal Clearances National Fuel Gas Code Vent Termination RequirementsFuel Conversion Kit Contents Mobile Home InstallationGas Conversion Canadian RequirementsAir Shutter adjustment and Burner Orifice Gas Conversion ProcedureConnect the Gas Supply Regulator AssemblyLeak Test Gas PressureRequired Inlet Gas Pressures in. W.C Required Manifold Pressure in. W.CDerating Procedure High Altitude AdjustmentRequirements Canadian RequirementsAir Shutter Settings See Figure Install the Log SetChecking the System Remote ControlCorrect flame picture Operation of ApplianceGlass Front MaintenanceGlass and Gasket Replacement Model Maintenance RecordGF 200 DV Lillehammer Illustrated Parts ListMatte Black Blue Black Ivory Forest Green Painted & Enamelled Cast Iron PartsToOFF. Do not force Access the lower controlsNormal service Jøtul North America Jøtul ASA