Jotul GF 200 DV manual Table of Contents

Page 3

Jøtul GF 200 Lillehammer Direct Vent Gas Heater

Manufactured and Distributed by:

Jøtul A.S.A.

Fredrikstad, Norway

Jøtul North America

Portland, Maine

Test Standards

This appliance complies

Warnock Hersey

 

 

 

 

 

 

 

with National Safety

C

 

 

 

 

 

US

standards and is tested

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and listed by Intertek

 

 

 

 

 

 

 

Testing Services of

Middleton, Wisconsin to ANSI Z21.88-1998 (NFPA 54) and CSA 2.33-M98 for Canada.

DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTER- ATION WILL VOID THE WARRANTY, CERTIFICA- TION AND LISTING OF THIS APPLIANCE.

Suggested Tools for

Installation and Service

External regulator (for Propane only)

Piping which complies with local code

Manual shutoff valve - T-Handle in MA

Sediment trap - if required by code

Tee joint

Pipe wrench

Pipe sealant

10mm open end wrench

1/2”, 7/16” open end wrench

Phillips head screwdriver

Flat head screwdriver

1/4” nut driver

Gloves

Safety glasses

Torx T20 screwdriver

Leak test solution

Reciprocating Saw

Power Drill

Table of Contents

 

 

Specifications

3

General Information

5

Safety Information

6

Hearth Protection Requirements

6

Clearance Requirements

7

Mantel and Trim Clearances

7

Venting Requirements

8

Draft Restrictors

8

Vertical Vent Systems

9

Co-linear Hearthmount Systems

10

Vent Height Requirements

11

Horizontal Vent Options

12

Wall Shield Installation

13

Vent Termination Clearances

14

Mobile Home Installation

15

Fuel Conversion

16

Gas Connection

17

Gas Pressure

18

High Altitude Adjustment

19

Air Shutter Adjustment

20

Log Set Installation

20

Thermostat / Remote Control

21

Checking the System

21

Operation

22

Maintenance

23

Maintenance Record

24

Parts Illustration

25

Replacement Parts List

26

Lighting Instructions

Back Cover

THIS PRODUCT MUST BE INSTALLED BY A LICENSED MASTER PLUMBER OR GAS- FITTER WHEN INSTALLED IN THE COM- MONWEALTH OF MASSACHUSETTS.

3

Image 3
Contents GF 200 DV Lillehammer Gas Heater Welcome to Jøtul Table of Contents Input Rates GF 200 DV Lillehammer OptionsGlass Panel General InformationMinimum Safety InformationLocating the Stove Hearth RequirementsClearance to Combustibles Vent Restriction Install the Exhaust Restrictor PlateInstall the Air Inlet Restrictor Plate Venting RequirementsVertical Venting Requirements Simpson Dura-Vent Ceiling Firestop #943 is requiredMinimum Vertical Rise =1 ft For a These guidelines must be followed Co-linear Hearthmount InstallationNot Vent TWO Appliances Into a Single Chimney Masonry or Prefabricated Chimney ConversionHorizontal Venting Horizontal Termination Horizontal vent with two elbows Wall Shield InstallationVent Terminal Clearances National Fuel Gas Code Vent Termination RequirementsCanadian Requirements Mobile Home InstallationFuel Conversion Kit Contents Gas ConversionAir Shutter adjustment and Burner Orifice Gas Conversion ProcedureConnect the Gas Supply Regulator AssemblyRequired Manifold Pressure in. W.C Gas PressureLeak Test Required Inlet Gas Pressures in. W.CCanadian Requirements High Altitude AdjustmentDerating Procedure RequirementsAir Shutter Settings See Figure Install the Log SetChecking the System Remote ControlCorrect flame picture Operation of ApplianceMaintenance Glass and Gasket ReplacementGlass Front Model Maintenance RecordGF 200 DV Lillehammer Illustrated Parts ListMatte Black Blue Black Ivory Forest Green Painted & Enamelled Cast Iron PartsAccess the lower controls Normal serviceToOFF. Do not force Jøtul North America Jøtul ASA