Lodge Manufacturing GMD1-80N manual III. Furnace Specifications Model

Page 9

All installations and services must be performed by qualified service personnel.

III. FURNACE SPECIFICATIONS

 

MODEL

GMD1-80

HEAT INPUT RATE (BTUH)

80,000

HEATING CAPACITY (BTUH)

65,000

BURNER ORIFICE-NAT. GAS (MM)

2.45

BURNER ORIFICE-PROP. GAS (DMS)

#53

GAS SUPPLY PRESSURE (IN.W.G.)

 

MINIMUM REQUIRED

 

PROPANE

11

NATURAL

5.5

MAXIMUM ALLOWED

 

PROPANE

14.0

NATURAL

14.0

GAS MANIFOLD PRESSURE (IN. W.G.)

 

PROPANE

10 + 0.3

NATURAL

3.5 + 0.3

VENT PIPE SIZE (INCHES)

4

DESIGN TEMPERATURE RISE (°F)

70

SEASONAL EFFICIENCY

 

(AFUE*, %)

81

*AFUE - INCLUDES STEADY STATE THERMAL EFFICIENCY AND OFF CYCLE LOSSES.

ELECTRICAL RATINGS AND SETTINGS:

ELECTRICAL SUPPLY: 115 VAC / 60HZ / 1 PHASE

MAXIMUM TIME DELAY TYPE FUSE OR HACR BREAKER RATING: 15 AMPS

TOTAL RATED CURRENT (AMPS): 7.15 (GMD1)

NOMINAL HEAT ANTICIPATOR SETTING -- 0.8 mA (GMD1)

DIMENSIONS & WEIGHTS:

CABINET: WIDTH - 18 IN., DEPTH – 25-1/2 IN., HEIGHT - 57 IN.

NO.70 MOBILE HOME BASE: WIDTH - 18-5/16 IN., DEPTH - 24¼ IN., HEIGHT - 4 IN.

WARM AIR DUCT: WIDTH – 12 IN., DEPTH – 12 IN.

COTTAGE BASE: WIDTH – 18-3/16 IN., DEPTH - 24¼ IN., HEIGHT – 14 IN.

FILTER QUANTITY & SIZE: 1 – 18” x 24 “

APPROXIMATE SHIPPING WEIGHT: 165 LBS.

PRODUCT LISTED UNDER ETL FILE NUMBER –

8

Image 9
Contents GAS-FIRED Furnace Safety Section Page Page Page Table of Contents Section Beginning Page Models GMD1-80N GMD1-80 III. Furnace Specifications ModelBlower Data IV. Installation Roof Jack Standard ChimneyFurnace Location Page Base Installation Page Alcove Installation Closet Installation ? Warning Hazard Combustion AIR Page GAS Piping Electrical Wiring AWG Propane Conversion Contents Quantity NAT. toManifold Removal and Orifice Change Page Adjustment of Heat Input Rate Initial Start UPOperating Instructions GAS Pressure Chart for ALL GMD1-80 Model Furnaces Burner Adjustment Furnace Checkout Procedure Setting Temperature RisePage Installers Instructions to User VI. Starting the Unit Refer to the Troubleshooting Section of this Manual Page Power must be disconnected before servicing Diagnostic FeaturesTurn Tstat Setting Above Room Temp Yes After GAS Valve OPENS, do the Burners IGNITE? Check ALL Inducer Blower Assembly VIII. Dealer MaintenanceElectrical BurnersGASKETS/SEALING Materials Inspecting the Venting SystemHeat Exchanger House AIR BlowerOn START-UP IX. User Information Section Inspection Areas Component LocationsFilter Location and Cleaning Appendix A. Replacement Parts List Page Appendix B Wiring Diagram