Lodge Manufacturing GMD1-80N manual After GAS Valve OPENS, do the Burners IGNITE?

Page 37

All installations and services must be performed by qualified service personnel.

Yes

AFTER GAS VALVE OPENS, DO THE BURNERS IGNITE?

Yes

No

MEASURE MANIFOLD

PRESSURE. IS

PRESSURE ADEQUATE?

Yes

CHECK IGNITOR

VOLTAGE DURING

20SECOND WARM-UP, IT SHOULD BE AT LEAST 105 VOLTS.

Yes

No

No

ADJUST TO 3.5" WC FOR

NATURAL GAS OR 10.0" WC

FOR PROPANE GAS

CORRECT LINE

VOLTAGE PROBLEM.

DO BURNERS STAY

No

LIT PAST PROOF

 

OF FLAME CHECK?

 

Yes

DOES THE INTEGRATED

 

CONTROL ENERGIZE THE

No

CIRCULATING AIR

 

BLOWER AFTER THE 45

 

SECOND TIME DELAY?

 

IS IGNITOR

No

 

 

POSITIONED

 

 

 

CORRECTLY?

 

 

 

 

 

CHECK FLAME

PROVING CIRCUIT

CHECK ACROSS THE

 

CIRCULATING AIR

No

BLOWER TERMINALS

 

"CIR N" & "HEAT"

 

FOR PROPER VOLTAGE.

 

 

 

REPOSITION TO

CORRECT LOCATION.

REPLACE THE

INTEGRATED CONTROL.

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOES THE CIRCULATING

 

No

 

 

 

 

No

 

 

 

 

DOES BLOWER

 

 

 

AIR FAN COME ON

 

 

 

 

 

 

 

 

SPIN FREELY?

 

 

 

 

WHEN ENERGIZED?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yes

 

 

 

Yes

 

 

 

IS CAPACITOR

 

 

 

 

 

 

 

 

 

 

 

WORKING PROPERLY?

 

 

 

 

 

 

 

 

 

 

 

 

 

CONFIRM IF EITHER BLOWER WHEEL IS RUBBING AGAINST HOUSING OR MOTOR SHAFT IS SPINNING FREELY AND REPAIR OR REPLACE AS NECESARRY.

REPLACE MOTOR

No

REPLACE CAPACITOR

36

Image 37
Contents GAS-FIRED Furnace Safety Section Page Page Page Table of Contents Section Beginning Page Models GMD1-80N GMD1-80 III. Furnace Specifications ModelBlower Data Standard Chimney IV. Installation Roof JackFurnace Location Page Base Installation Page Alcove Installation Closet Installation ? Warning Hazard Combustion AIR Page GAS Piping Electrical Wiring AWG Propane Conversion Contents Quantity NAT. toManifold Removal and Orifice Change Page Initial Start UP Adjustment of Heat Input RateOperating Instructions GAS Pressure Chart for ALL GMD1-80 Model Furnaces Burner Adjustment Furnace Checkout Procedure Setting Temperature RisePage Installers Instructions to User VI. Starting the Unit Refer to the Troubleshooting Section of this Manual Page Power must be disconnected before servicing Diagnostic FeaturesTurn Tstat Setting Above Room Temp Yes After GAS Valve OPENS, do the Burners IGNITE? Check ALL Inducer Blower Assembly VIII. Dealer MaintenanceElectrical BurnersGASKETS/SEALING Materials Inspecting the Venting SystemHeat Exchanger House AIR BlowerOn START-UP IX. User Information Section Inspection Areas Component LocationsFilter Location and Cleaning Appendix A. Replacement Parts List Page Appendix B Wiring Diagram