All installations and services must be performed by qualified service personnel.
VI. STARTING THE UNIT
A. SEQUENCE OF OPERATIONS
AT ANY TIME THE
GAS VALVE IS
NOT ENERGIZED
START
CONTINUOUS SAFE OPERATION CHECK IF FLAME SIMULATION CONDITION PRESENT OR
START TRIAL FOR IGNITION
THERMOSTAT CALLS FOR HEAT, CONTACTS CLOSE
CONTROL BOARD ENERGIZED,
INDUCER ENERGIZED
PRESSURE SWITCH SENSES ADEQUATE DIFFERENTIAL PRESSURE CONTACTS CLOSE
POWER IS APPLIED TO THE SILICON NITRIDE IGNITOR. IGNITOR
AFTER IGNITOR
THE GAS VALVE IS
ENERGIZED TO OPEN
POWER INTERRUPTION
SYSTEM SHUTS OFF,
RESTARTS WHEN POWER IS RESTORED.
|
|
|
|
|
|
FLAME MUST BE |
| IF FLAME IS NOT | |||
DETECTED WITHIN |
| DETECTED, THE GAS VALVE | |||
4 SECONDS IF FLAME |
| IS | |||
IS DETECTED, THE |
| IGNITOR IS TURNED OFF AND | |||
| THE CONTROL BOARD CONTROL | ||||
TIME BEGINS (45 SECONDS) |
| GOES INTO "RETRY" SEQUENCE | |||
|
|
|
|
|
|
|
|
|
|
|
|
30