Yukon Advanced Optics Oil Furnace owner manual Polar/Eagle, Oil/Wood - Gas/Wood, Safe Operation

Page 1
OWNER'S

OWNER'S

MANUAL

Assembly

Installation

Operation

Repair Parts

Maintenance Tips

Model No.

LWO-112 (Oil Fired)

LWG-112 (Gas Fired)

LWO-168 (Oil Fired)

LWG-168 (Gas Fired)

CAUTION:

Read Rules And

Instructions

Carefully For

Safe Operation

IMPORTANT: Installation must be made in

accordance with NFPA, and state and local ordinances

which may differ from this installation manual.

I

HUSKY/EAGLE YUKON

YUKON

POLAR/EAGLE II

 

Oil/Wood - Gas/Wood

Warm Air Central Heating Furnaces

All furnaces in this owner's manual are

UL Listed in UL file #MH 11057

Alpha American Co., 10 Industrial Blvd., Palisade, MN 56469

www.yukon-eagle.com 1-800-358-0060
Image 1
Contents Oil/Wood - Gas/Wood POLAR/EAGLEWarm Air Central Heating Furnaces LWO-112Oil Fired LWG-112Gas FiredFor repair or replacement parts FOR YOUR SAFETYDANGER or call 1-800-358-0060PLAN YOUR INSTALLATION TABLE OF CONTENTSINSTALLATION MAINTENANCESTOP FOR SAFETY Safety StatementsREAD THROUGH THE ENTIRE MANUAL extra safety precautions should be takenINSPECT SHIPMENT Unpack and Check Your CartonsPACKING LIST FIG.vMORE HEAT EXCHANGE SURFACE Furnace Features - Eagle I - HuskyMEANS LESS HEAT UP THE CHIMNEY xTHE OIL OR GAS BURNER FIRES INTO~ w z u | yv xFurnace Features - Eagle I - Husky uYUKONTROL SOLID-STATE Furnace Features - Eagle II - PolarzFIRE BRICK LINING EXTENDS Furnace Features - Eagle II - Polar w|z uMODEL LWO-112Oil SpecificationsInput rating 1.0 G.P.H. - 80 HUnit Dimensions Plan Your InstallationPLAN YOUR INSTALLATION RULES FOR SAFE INSTALLATION AND OPERATIONCLEARANCES TO COMBUSTIBLES BE SURE TO INSTALL DUCT WORKWITH CLEARANCES SHOWN Plan Your InstallationPlan Your Installation TYPICAL INSTALLATIONBE INSTALLED WITH A METAL CONDENSATE PAN EVENT OF ELECTRIC POWER OR FURNACE FAN FAILUREDRAFT TUBE INSTALLATION InstallationPLACE FURNACE SECONDARY AIR INTAKE COVERInstallation CUT AWAY VIEW BURNER COMBUSTION CHAMBEROIL BURNER INSTALLATION Install burner as followsDraft Tube Assembly InstallationDRAFT DAMPER CONTROLFIG. 14-A FIG. 14-B InstallationSMOKE BAFFLES INSTALLING THE HONEYWELL FAN/LIMIT CONTROL InstallationFan Limit Control TYPICAL THERMOSTAT SETTINGS InstallationMOUNTING THE THERMOSTATS FIG.FIG. InstallationFUEL TANKS AND FUEL LINES SINGLE LINE SYSTEMGAS PIPE SIZING InstallationGAS PIPING FIG.Field Controls Model WMO-1Safety Switch InstallationFUME SENSOR GAS MODELS ONLY FIG.ELECTRIC WIRING InstallationWIRING THE FURNACE DS-103DAMPER CONTROLOIL OR GAS AND WOOD HEATING ONLY 24 Volt Field WiringOIL OR GAS AND WOOD HEATING WITH AIR CONDITIONING CONNECTING SMOKE PIPE InstallationFIG. LESSER CLEARANCES TO COMBUSTIBLEA MANOMETER MUST BE USED TO ACCURATELY ADJUST FLUE DRAFTInstallation MAKE THESE ADJUSTMENTS WHEN INSTALLINGPROPER CHIMNEYS InstallationCHOOSING A CHIMNEY Installation COMBUSTION AIR InstallationFIG. FIG. FIGBTU Per Hour Input InstallationOperating Instructions To start the oil burner on a new installationOIL FIRING THE UNIT STARTING BURNER AFTER IGNITION FAILURETo Start the Gas burner on new installation Gas Firing the UnitOperating Instructions FIG.BEST WOOD TO BURN Operating InstructionsBTU’s EquivalentSTARTING WOOD FIRE WITH GAS OR OIL BURNER Operating InstructionsHAND FIRING WOOD Operating Instructions HOW TO START A COAL FIREWHAT SIZE COAL SHOULD I BURN? MAINTAINING A COAL FIREOPERATING INSTRUCTIONS FOR BURNING COAL Operating InstructionsON 1/2-INCHOPENING GRATES Optional OIL AND WOOD HEATING ONLY Wiring DiagramsWiring Diagrams OIL AND WOOD HEATING WITH A/CWiring Diagrams GAS AND WOOD HEATING ONLYWiring Diagrams GAS AND WOOD HEATING WITH A/CRECOVERING UNBURNED COAL MaintenanceGRATE CARE -ASHREMOVAL ASH DISPOSALCLEANING FURNACE AND CHIMNEY FLUE PIPES MaintenanceSMOKE PIPE, CHIMNEY AND SECONDARY HEAT EXCHANGER Secondary Heat Exchanger Eagle I - HuskyFURNACE BLOWER ADJUSTMENT MaintenanceFIG. FIG. FIG. FIG. DUCT WORK AND BLOWER SPEED ADJUSTMENT MaintenanceTESTING INSTALLATIONS FOR EFFICIENCY MaintenanceFIG. TEST PROCEDURE Step MaintenanceStep StepFIREBRICK PLACEMENT MaintenanceFIREBRICK PLACEMENT Models LWO-112& LWG-112ONLY Fig. Lower RowOIL BURNER MAINTENANCE MaintenanceMAINTENANCE AT THE END OF THE HEATING SEASON MAINTENANCE AT THE START OF THE HEATING SEASONHOW TO PREVENT RUST AND CORROSION MaintenanceDISPOSAL OF ASHES CREOSOTE-FORMATIONAND NEED FOR REMOVALSMOKE IN THE FURNACE ROOM MaintenanceChimney causes FIG.OVER HEATING WHEN BURNING SOLID FUEL AS MaintenanceYOUR PRIMARY SOURCE OF HEAT GAS OR OIL PART OF FURNACE TOO LARGE FOR THE HOMEEAGLE I - HUSKY MODELS LWO-112& LWG-112 Exploded Views & Parts ListLeft Hand Exploded Views & Parts ListRight Hand DescriptionExploded Views & Parts List EAGLE II - POLAR MODELS LWO-168& LWG-168Exploded Views & Parts List Left Hand ShownKey No Left HandExploded Views & Parts List WAYNE MODEL MSR OIL BURNERGUN ASSEMBLY Exploded Views & Parts List BURNER COMPONENTS WAYNE MODEL MSRMSR GUN ASSEMBLY DETAIL Part DescriptionExploded Views & Parts List WAYNE MODEL P250AF-DIN GAS BURNERExploded Views & Parts List BURNER COMPONENTS WAYNE MODEL P250AF-DINPart Description Part NumberCHART IS FOR DETERMINING MOTOR HORSEPOWER NEEDS CIRCULATING FAN PERFORMANCE CURVE CHARTMODELS LWO-112AND LWG-112 THIS CIRCULATING FAN PERFORMANCE CURVEExploded Views & Parts List MODELS LWO-168AND LWG-168CIRCULATING FAN PERFORMANCE CURVE CHART CHART IS FOR DETERMINING MOTOR HORSEPOWER NEEDSSERVICE HINTS- OIL TroubleshootingNotes Assembly Installation Operation Repair Parts HOW TO ORDER REPAIR PARTSYUKONEAGLE OWNERS MANUAL