Yukon Advanced Optics Oil Furnace Unpack and Check Your Cartons, Inspect Shipment, Packing List

Page 5
Unpack and Check Your Cartons

Unpack and Check Your Cartons

INSPECT SHIPMENT

Your furnace is shipped complete in three cartons. Note any damage to the shipping cartons. Remove all items from your shipping cartons. Check all items against the packing list below. Note any items lost or damaged in shipment. Refer to the exploded view and parts list in the back of the manual for the part names and numbers of missing or damaged items. Keep the small parts in the parts bag until you are ready to install them.

PACKING LIST

1.Carton One: The basic furnace comes in the crate. Inside the filter door, below the flue outlet, is the pre- assembled, circulating fan, motor, belt, drives and drip shield. The air filter lies in a frame above the fan. Inside the furnace wood-firing door are:

• Three wood grates (installed)

 

• Secondary air shut-off assembly

 

• Smoke pipe draw collar (Polar Unit Only)

FIG. 1

Primary air draft tube

Door handle weldment and handle assembly for both fire door and ash pan.

Remove these items and set aside for later installation.

2.Carton Two: This accessory package contains the following items:

Secondary air intake cover

Thermostats

Barometric damper

Fan and limit control

Damper control unit

Transformer

Wiring harness

Fume sensor (gas only)

Owner's manual

Warranty sheet

Remove these items and set aside for later installation.

3.Carton Three: The oil or gas burner is in this carton. It is pre-assembled and ready for installation.

Questions? Visit www.yukon-eagle.com or call 1-800-358-0060

5

Image 5
Contents Oil/Wood - Gas/Wood POLAR/EAGLEWarm Air Central Heating Furnaces LWO-112Oil Fired LWG-112Gas FiredFor repair or replacement parts FOR YOUR SAFETYDANGER or call 1-800-358-0060PLAN YOUR INSTALLATION TABLE OF CONTENTSINSTALLATION MAINTENANCESTOP FOR SAFETY Safety StatementsREAD THROUGH THE ENTIRE MANUAL extra safety precautions should be takenINSPECT SHIPMENT Unpack and Check Your CartonsPACKING LIST FIG.vMORE HEAT EXCHANGE SURFACE Furnace Features - Eagle I - HuskyMEANS LESS HEAT UP THE CHIMNEY xTHE OIL OR GAS BURNER FIRES INTOFurnace Features - Eagle I - Husky yv x~ w z u | zFIRE BRICK LINING EXTENDS Furnace Features - Eagle II - PolaruYUKONTROL SOLID-STATE Furnace Features - Eagle II - Polar w|z uMODEL LWO-112Oil SpecificationsInput rating 1.0 G.P.H. - 80 HUnit Dimensions Plan Your InstallationPLAN YOUR INSTALLATION RULES FOR SAFE INSTALLATION AND OPERATIONCLEARANCES TO COMBUSTIBLES BE SURE TO INSTALL DUCT WORKWITH CLEARANCES SHOWN Plan Your InstallationPlan Your Installation TYPICAL INSTALLATIONBE INSTALLED WITH A METAL CONDENSATE PAN EVENT OF ELECTRIC POWER OR FURNACE FAN FAILUREDRAFT TUBE INSTALLATION InstallationPLACE FURNACE SECONDARY AIR INTAKE COVERInstallation CUT AWAY VIEW BURNER COMBUSTION CHAMBEROIL BURNER INSTALLATION Install burner as followsDraft Tube Assembly InstallationDRAFT DAMPER CONTROLSMOKE BAFFLES InstallationFIG. 14-A FIG. 14-B Fan Limit Control InstallationINSTALLING THE HONEYWELL FAN/LIMIT CONTROL TYPICAL THERMOSTAT SETTINGS InstallationMOUNTING THE THERMOSTATS FIG.FIG. InstallationFUEL TANKS AND FUEL LINES SINGLE LINE SYSTEMGAS PIPE SIZING InstallationGAS PIPING FIG.Field Controls Model WMO-1Safety Switch InstallationFUME SENSOR GAS MODELS ONLY FIG.ELECTRIC WIRING InstallationWIRING THE FURNACE DS-103DAMPER CONTROLOIL OR GAS AND WOOD HEATING WITH AIR CONDITIONING 24 Volt Field WiringOIL OR GAS AND WOOD HEATING ONLY CONNECTING SMOKE PIPE InstallationFIG. LESSER CLEARANCES TO COMBUSTIBLEA MANOMETER MUST BE USED TO ACCURATELY ADJUST FLUE DRAFTInstallation MAKE THESE ADJUSTMENTS WHEN INSTALLINGCHOOSING A CHIMNEY InstallationPROPER CHIMNEYS Installation COMBUSTION AIR InstallationFIG. FIG. FIGBTU Per Hour Input InstallationOperating Instructions To start the oil burner on a new installationOIL FIRING THE UNIT STARTING BURNER AFTER IGNITION FAILURETo Start the Gas burner on new installation Gas Firing the UnitOperating Instructions FIG.BEST WOOD TO BURN Operating InstructionsBTU’s EquivalentHAND FIRING WOOD Operating InstructionsSTARTING WOOD FIRE WITH GAS OR OIL BURNER Operating Instructions HOW TO START A COAL FIREWHAT SIZE COAL SHOULD I BURN? MAINTAINING A COAL FIREON 1/2-INCHOPENING GRATES Optional Operating InstructionsOPERATING INSTRUCTIONS FOR BURNING COAL OIL AND WOOD HEATING ONLY Wiring DiagramsWiring Diagrams OIL AND WOOD HEATING WITH A/CWiring Diagrams GAS AND WOOD HEATING ONLYWiring Diagrams GAS AND WOOD HEATING WITH A/CRECOVERING UNBURNED COAL MaintenanceGRATE CARE -ASHREMOVAL ASH DISPOSALCLEANING FURNACE AND CHIMNEY FLUE PIPES MaintenanceSMOKE PIPE, CHIMNEY AND SECONDARY HEAT EXCHANGER Secondary Heat Exchanger Eagle I - HuskyFIG. FIG. FIG. FIG. MaintenanceFURNACE BLOWER ADJUSTMENT DUCT WORK AND BLOWER SPEED ADJUSTMENT MaintenanceFIG. MaintenanceTESTING INSTALLATIONS FOR EFFICIENCY TEST PROCEDURE Step MaintenanceStep StepFIREBRICK PLACEMENT MaintenanceFIREBRICK PLACEMENT Models LWO-112& LWG-112ONLY Fig. Lower RowOIL BURNER MAINTENANCE MaintenanceMAINTENANCE AT THE END OF THE HEATING SEASON MAINTENANCE AT THE START OF THE HEATING SEASONHOW TO PREVENT RUST AND CORROSION MaintenanceDISPOSAL OF ASHES CREOSOTE-FORMATIONAND NEED FOR REMOVALSMOKE IN THE FURNACE ROOM MaintenanceChimney causes FIG.OVER HEATING WHEN BURNING SOLID FUEL AS MaintenanceYOUR PRIMARY SOURCE OF HEAT GAS OR OIL PART OF FURNACE TOO LARGE FOR THE HOMEEAGLE I - HUSKY MODELS LWO-112& LWG-112 Exploded Views & Parts ListLeft Hand Exploded Views & Parts ListRight Hand DescriptionExploded Views & Parts List EAGLE II - POLAR MODELS LWO-168& LWG-168Exploded Views & Parts List Left Hand ShownKey No Left HandGUN ASSEMBLY WAYNE MODEL MSR OIL BURNERExploded Views & Parts List Exploded Views & Parts List BURNER COMPONENTS WAYNE MODEL MSRMSR GUN ASSEMBLY DETAIL Part DescriptionExploded Views & Parts List WAYNE MODEL P250AF-DIN GAS BURNERExploded Views & Parts List BURNER COMPONENTS WAYNE MODEL P250AF-DINPart Description Part NumberCHART IS FOR DETERMINING MOTOR HORSEPOWER NEEDS CIRCULATING FAN PERFORMANCE CURVE CHARTMODELS LWO-112AND LWG-112 THIS CIRCULATING FAN PERFORMANCE CURVEExploded Views & Parts List MODELS LWO-168AND LWG-168CIRCULATING FAN PERFORMANCE CURVE CHART CHART IS FOR DETERMINING MOTOR HORSEPOWER NEEDSSERVICE HINTS- OIL TroubleshootingNotes Assembly Installation Operation Repair Parts HOW TO ORDER REPAIR PARTSYUKONEAGLE OWNERS MANUAL