Specifications
| MODEL |
Input rating | ......................................................................................................................................140,000 BTU/HR |
Nozzle | 1.0 G.P.H. - 80 H |
Burner | Wayne Model - MSR |
Input rating | MODEL | 140,000 BTU/HR |
| ||
Output rating | 112,000 BTU/HR | |
| NAT | LP |
Orifice | 7/32" (.218 dia.) | 9 (.136 dia.) |
Manifold Pressure | 3.5 W.C.P | 11.0 W.C.P. |
Burner | Wayne Model | |
Blower Size (Belt Drive) | MODEL | 10" x 10" |
| ||
Blower C.F.M | 800 - 1800 | |
Motor Size | 1/3 - 1/2 - 3/4 HP | |
Firebrick Lined | (7) 9” x 6” x 2” • (8) 12” x 6” x 2” | |
Cast Iron Grates - Standard | (3) 16” x 8” | |
Wood Fire Door | 11" x 10" | |
Air Filter | 20" x 25" x 1" | |
Wood Combustion Chamber Size | 24" x 16" |
| MODEL |
Input rating | 189,000 BTU/HR |
Output rating | 151,000 BTU/HR |
Nozzle | 1.35 G.P.H - 80 H |
Burner | Wayne Model - MSR |
Input rating | MODEL | 189,000 BTU/HR |
| ||
Output rating | 151,000 BTU/HR | |
| NAT | LP |
Orifice | “F" (.257 dia.) | “23” (.154 dia.) |
Manifold Pressure | 3.5 W.C.P | 11.0 W.C.P. |
Burner | Wayne Model | |
Blower Size (Belt Drive) | MODELS | 11" x 10" |
| ||
Blower C.F.M | 1200 - 2000 | |
Motor Size | 1/3 - 1/2 - 3/4 HP | |
Firebrick | (10) 9” x 6” x 2” • (7) 12” x 6” x 2” • (1) 9” x | |
Cast Iron Grates - Standard | (3) 18” x 8” | |
Wood Fire Door | ||
Air Filter | 20" x 25" x 1" | |
Wood Combustion Chamber Size | 24" x 18" |
NOTE: It is recommended that a 2", non combustible, raised pad be used for the furnace. This will prevent moisture from getting under the furnace and causing corrosion.