Yukon Advanced Optics
Oil Furnace
owner manual
Oil And Wood Heating With A/C, Wiring Diagrams
Troubleshooting
Specifications
Install
Parts list
Wiring Diagrams
Electric Wiring
Maintenance
Draft Tube Assembly
TEST PROCEDURE Step
Accurately Adjust Flue Draft
Page 38
Wiring Diagrams
OIL AND WOOD HEATING WITH A/C
38
Page 37
Page 39
Image 38
Page 37
Page 39
Contents
Warm Air Central Heating Furnaces
POLAR/EAGLE
Oil/Wood - Gas/Wood
LWO-112Oil Fired LWG-112Gas Fired
DANGER
FOR YOUR SAFETY
For repair or replacement parts
or call 1-800-358-0060
INSTALLATION
TABLE OF CONTENTS
PLAN YOUR INSTALLATION
MAINTENANCE
READ THROUGH THE ENTIRE MANUAL
Safety Statements
STOP FOR SAFETY
extra safety precautions should be taken
PACKING LIST
Unpack and Check Your Cartons
INSPECT SHIPMENT
FIG.
MEANS LESS HEAT UP THE CHIMNEY
Furnace Features - Eagle I - Husky
vMORE HEAT EXCHANGE SURFACE
xTHE OIL OR GAS BURNER FIRES INTO
Furnace Features - Eagle I - Husky
yv x
~ w z u |
zFIRE BRICK LINING EXTENDS
Furnace Features - Eagle II - Polar
uYUKONTROL SOLID-STATE
w|z u
Furnace Features - Eagle II - Polar
Input rating
Specifications
MODEL LWO-112Oil
1.0 G.P.H. - 80 H
PLAN YOUR INSTALLATION
Plan Your Installation
Unit Dimensions
RULES FOR SAFE INSTALLATION AND OPERATION
WITH CLEARANCES SHOWN
BE SURE TO INSTALL DUCT WORK
CLEARANCES TO COMBUSTIBLES
Plan Your Installation
BE INSTALLED WITH A METAL CONDENSATE PAN
TYPICAL INSTALLATION
Plan Your Installation
EVENT OF ELECTRIC POWER OR FURNACE FAN FAILURE
PLACE FURNACE
Installation
DRAFT TUBE INSTALLATION
SECONDARY AIR INTAKE COVER
OIL BURNER INSTALLATION
CUT AWAY VIEW BURNER COMBUSTION CHAMBER
Installation
Install burner as follows
DRAFT
Installation
Draft Tube Assembly
DAMPER CONTROL
SMOKE BAFFLES
Installation
FIG. 14-A FIG. 14-B
Fan Limit Control
Installation
INSTALLING THE HONEYWELL FAN/LIMIT CONTROL
MOUNTING THE THERMOSTATS
Installation
TYPICAL THERMOSTAT SETTINGS
FIG.
FUEL TANKS AND FUEL LINES
Installation
FIG.
SINGLE LINE SYSTEM
GAS PIPING
Installation
GAS PIPE SIZING
FIG.
FUME SENSOR GAS MODELS ONLY
Installation
Field Controls Model WMO-1Safety Switch
FIG.
WIRING THE FURNACE
Installation
ELECTRIC WIRING
DS-103DAMPER CONTROL
OIL OR GAS AND WOOD HEATING WITH AIR CONDITIONING
24 Volt Field Wiring
OIL OR GAS AND WOOD HEATING ONLY
FIG.
Installation
CONNECTING SMOKE PIPE
LESSER CLEARANCES TO COMBUSTIBLE
Installation
ACCURATELY ADJUST FLUE DRAFT
A MANOMETER MUST BE USED TO
MAKE THESE ADJUSTMENTS WHEN INSTALLING
CHOOSING A CHIMNEY
Installation
PROPER CHIMNEYS
Installation
FIG.
Installation
COMBUSTION AIR
FIG. FIG
Installation
BTU Per Hour Input
OIL FIRING THE UNIT
To start the oil burner on a new installation
Operating Instructions
STARTING BURNER AFTER IGNITION FAILURE
Operating Instructions
Gas Firing the Unit
To Start the Gas burner on new installation
FIG.
BTU’s
Operating Instructions
BEST WOOD TO BURN
Equivalent
HAND FIRING WOOD
Operating Instructions
STARTING WOOD FIRE WITH GAS OR OIL BURNER
WHAT SIZE COAL SHOULD I BURN?
HOW TO START A COAL FIRE
Operating Instructions
MAINTAINING A COAL FIRE
ON 1/2-INCHOPENING GRATES Optional
Operating Instructions
OPERATING INSTRUCTIONS FOR BURNING COAL
Wiring Diagrams
OIL AND WOOD HEATING ONLY
OIL AND WOOD HEATING WITH A/C
Wiring Diagrams
GAS AND WOOD HEATING ONLY
Wiring Diagrams
GAS AND WOOD HEATING WITH A/C
Wiring Diagrams
GRATE CARE -ASHREMOVAL
Maintenance
RECOVERING UNBURNED COAL
ASH DISPOSAL
SMOKE PIPE, CHIMNEY AND SECONDARY HEAT EXCHANGER
Maintenance
CLEANING FURNACE AND CHIMNEY FLUE PIPES
Secondary Heat Exchanger Eagle I - Husky
FIG. FIG. FIG. FIG.
Maintenance
FURNACE BLOWER ADJUSTMENT
Maintenance
DUCT WORK AND BLOWER SPEED ADJUSTMENT
FIG.
Maintenance
TESTING INSTALLATIONS FOR EFFICIENCY
Step
Maintenance
TEST PROCEDURE Step
Step
FIREBRICK PLACEMENT
Maintenance
FIREBRICK PLACEMENT
Models LWO-112& LWG-112ONLY Fig. Lower Row
MAINTENANCE AT THE END OF THE HEATING SEASON
Maintenance
OIL BURNER MAINTENANCE
MAINTENANCE AT THE START OF THE HEATING SEASON
DISPOSAL OF ASHES
Maintenance
HOW TO PREVENT RUST AND CORROSION
CREOSOTE-FORMATIONAND NEED FOR REMOVAL
Chimney causes
Maintenance
SMOKE IN THE FURNACE ROOM
FIG.
YOUR PRIMARY SOURCE OF HEAT
Maintenance
OVER HEATING WHEN BURNING SOLID FUEL AS
GAS OR OIL PART OF FURNACE TOO LARGE FOR THE HOME
Exploded Views & Parts List
EAGLE I - HUSKY MODELS LWO-112& LWG-112
Right Hand
Exploded Views & Parts List
Left Hand
Description
EAGLE II - POLAR MODELS LWO-168& LWG-168
Exploded Views & Parts List
Key No
Left Hand Shown
Exploded Views & Parts List
Left Hand
GUN ASSEMBLY
WAYNE MODEL MSR OIL BURNER
Exploded Views & Parts List
MSR GUN ASSEMBLY DETAIL
BURNER COMPONENTS WAYNE MODEL MSR
Exploded Views & Parts List
Part Description
WAYNE MODEL P250AF-DIN GAS BURNER
Exploded Views & Parts List
Part Description
BURNER COMPONENTS WAYNE MODEL P250AF-DIN
Exploded Views & Parts List
Part Number
MODELS LWO-112AND LWG-112
CIRCULATING FAN PERFORMANCE CURVE CHART
CHART IS FOR DETERMINING MOTOR HORSEPOWER NEEDS
THIS CIRCULATING FAN PERFORMANCE CURVE
CIRCULATING FAN PERFORMANCE CURVE CHART
MODELS LWO-168AND LWG-168
Exploded Views & Parts List
CHART IS FOR DETERMINING MOTOR HORSEPOWER NEEDS
Troubleshooting
SERVICE HINTS- OIL
Notes
YUKONEAGLE
HOW TO ORDER REPAIR PARTS
Assembly Installation Operation Repair Parts
OWNERS MANUAL
Related pages
All Diagram page
Appendix 5. Block Diagram for CBM America iDP3240
Block Diagrams BD CD Section for Sony HCD-MD373
Fabric care chart for Samsung WD90N643OAW/EE
Package Diagrams for Cypress CY14B104L
Q1860-90918 Parts and diagrams for HP 5100LE
INFORMATION - 8 Hour Lubrication Chart P/N for Alamo 803350C
Transfer Switch Wiring Diagram for Briggs & Stratton 01814-0
Tractor o o Model Number SCHEMATmC for Craftsman 917.273373
Diagrama DEL Circuito for Fujioh FDR-4200
Diagram for Impex WM 1407
Why might
S.M.A.R.T.
not be useful for all users?
Top
Page
Image
Contents