HEAT EXCHANGER

Do not burn green or freshly felled wood. This may cause creosote and soot to build up in chimney, smoke pipe, and secondary heat exchanger. These should be checked and cleaned several times each heating season.

CLEANING FURNACE AND CHIMNEY FLUE

PIPES

Frequently check and clean the furnace flue pipes and chimney. Soot and fly ash should not be allowed to build up on any of these surfaces. Chimneys are best cleaned professionally.

Secondary Heat Exchanger

Eagle I - Husky

Secondary Heat Exchanger

Eagle II - Polar

42

Image 42
Contents Warm Air Central Heating Furnaces POLAR/EAGLEOil/Wood - Gas/Wood LWO-112Oil Fired LWG-112Gas FiredDANGER FOR YOUR SAFETYFor repair or replacement parts or call 1-800-358-0060INSTALLATION TABLE OF CONTENTSPLAN YOUR INSTALLATION MAINTENANCEREAD THROUGH THE ENTIRE MANUAL Safety StatementsSTOP FOR SAFETY extra safety precautions should be takenPACKING LIST Unpack and Check Your CartonsINSPECT SHIPMENT FIG.MEANS LESS HEAT UP THE CHIMNEY Furnace Features - Eagle I - HuskyvMORE HEAT EXCHANGE SURFACE xTHE OIL OR GAS BURNER FIRES INTOyv x ~ w z u |Furnace Features - Eagle I - Husky Furnace Features - Eagle II - Polar uYUKONTROL SOLID-STATEzFIRE BRICK LINING EXTENDS w|z u Furnace Features - Eagle II - PolarInput rating SpecificationsMODEL LWO-112Oil 1.0 G.P.H. - 80 HPLAN YOUR INSTALLATION Plan Your InstallationUnit Dimensions RULES FOR SAFE INSTALLATION AND OPERATIONWITH CLEARANCES SHOWN BE SURE TO INSTALL DUCT WORKCLEARANCES TO COMBUSTIBLES Plan Your InstallationBE INSTALLED WITH A METAL CONDENSATE PAN TYPICAL INSTALLATIONPlan Your Installation EVENT OF ELECTRIC POWER OR FURNACE FAN FAILUREPLACE FURNACE InstallationDRAFT TUBE INSTALLATION SECONDARY AIR INTAKE COVEROIL BURNER INSTALLATION CUT AWAY VIEW BURNER COMBUSTION CHAMBERInstallation Install burner as followsDRAFT InstallationDraft Tube Assembly DAMPER CONTROLInstallation FIG. 14-A FIG. 14-BSMOKE BAFFLES Installation INSTALLING THE HONEYWELL FAN/LIMIT CONTROLFan Limit Control MOUNTING THE THERMOSTATS InstallationTYPICAL THERMOSTAT SETTINGS FIG.FUEL TANKS AND FUEL LINES InstallationFIG. SINGLE LINE SYSTEMGAS PIPING InstallationGAS PIPE SIZING FIG.FUME SENSOR GAS MODELS ONLY InstallationField Controls Model WMO-1Safety Switch FIG.WIRING THE FURNACE InstallationELECTRIC WIRING DS-103DAMPER CONTROL24 Volt Field Wiring OIL OR GAS AND WOOD HEATING ONLYOIL OR GAS AND WOOD HEATING WITH AIR CONDITIONING FIG. InstallationCONNECTING SMOKE PIPE LESSER CLEARANCES TO COMBUSTIBLEInstallation ACCURATELY ADJUST FLUE DRAFTA MANOMETER MUST BE USED TO MAKE THESE ADJUSTMENTS WHEN INSTALLINGInstallation PROPER CHIMNEYSCHOOSING A CHIMNEY Installation FIG. InstallationCOMBUSTION AIR FIG. FIGInstallation BTU Per Hour InputOIL FIRING THE UNIT To start the oil burner on a new installationOperating Instructions STARTING BURNER AFTER IGNITION FAILUREOperating Instructions Gas Firing the UnitTo Start the Gas burner on new installation FIG.BTU’s Operating InstructionsBEST WOOD TO BURN EquivalentOperating Instructions STARTING WOOD FIRE WITH GAS OR OIL BURNERHAND FIRING WOOD WHAT SIZE COAL SHOULD I BURN? HOW TO START A COAL FIREOperating Instructions MAINTAINING A COAL FIREOperating Instructions OPERATING INSTRUCTIONS FOR BURNING COALON 1/2-INCHOPENING GRATES Optional Wiring Diagrams OIL AND WOOD HEATING ONLYOIL AND WOOD HEATING WITH A/C Wiring DiagramsGAS AND WOOD HEATING ONLY Wiring DiagramsGAS AND WOOD HEATING WITH A/C Wiring DiagramsGRATE CARE -ASHREMOVAL MaintenanceRECOVERING UNBURNED COAL ASH DISPOSALSMOKE PIPE, CHIMNEY AND SECONDARY HEAT EXCHANGER MaintenanceCLEANING FURNACE AND CHIMNEY FLUE PIPES Secondary Heat Exchanger Eagle I - HuskyMaintenance FURNACE BLOWER ADJUSTMENTFIG. FIG. FIG. FIG. Maintenance DUCT WORK AND BLOWER SPEED ADJUSTMENTMaintenance TESTING INSTALLATIONS FOR EFFICIENCYFIG. Step MaintenanceTEST PROCEDURE Step StepFIREBRICK PLACEMENT MaintenanceFIREBRICK PLACEMENT Models LWO-112& LWG-112ONLY Fig. Lower RowMAINTENANCE AT THE END OF THE HEATING SEASON MaintenanceOIL BURNER MAINTENANCE MAINTENANCE AT THE START OF THE HEATING SEASONDISPOSAL OF ASHES MaintenanceHOW TO PREVENT RUST AND CORROSION CREOSOTE-FORMATIONAND NEED FOR REMOVALChimney causes MaintenanceSMOKE IN THE FURNACE ROOM FIG.YOUR PRIMARY SOURCE OF HEAT MaintenanceOVER HEATING WHEN BURNING SOLID FUEL AS GAS OR OIL PART OF FURNACE TOO LARGE FOR THE HOMEExploded Views & Parts List EAGLE I - HUSKY MODELS LWO-112& LWG-112Right Hand Exploded Views & Parts ListLeft Hand DescriptionEAGLE II - POLAR MODELS LWO-168& LWG-168 Exploded Views & Parts ListKey No Left Hand ShownExploded Views & Parts List Left HandWAYNE MODEL MSR OIL BURNER Exploded Views & Parts ListGUN ASSEMBLY MSR GUN ASSEMBLY DETAIL BURNER COMPONENTS WAYNE MODEL MSRExploded Views & Parts List Part DescriptionWAYNE MODEL P250AF-DIN GAS BURNER Exploded Views & Parts ListPart Description BURNER COMPONENTS WAYNE MODEL P250AF-DINExploded Views & Parts List Part NumberMODELS LWO-112AND LWG-112 CIRCULATING FAN PERFORMANCE CURVE CHARTCHART IS FOR DETERMINING MOTOR HORSEPOWER NEEDS THIS CIRCULATING FAN PERFORMANCE CURVECIRCULATING FAN PERFORMANCE CURVE CHART MODELS LWO-168AND LWG-168Exploded Views & Parts List CHART IS FOR DETERMINING MOTOR HORSEPOWER NEEDSTroubleshooting SERVICE HINTS- OILNotes YUKONEAGLE HOW TO ORDER REPAIR PARTSAssembly Installation Operation Repair Parts OWNERS MANUAL