To Start the Gas burner on new installation
1.With gas line in “off” position, install burner using gasket and tighten down with 3 nuts to furnace.
2.Connect 110 Volt power to burner
3.Connect 24 Volt power to the burner from the
4.Set room thermostat 10 degrees above room temperature.
5.Allow burner to operate for 2 minutes until all air is purged from gas line.
6.Adjust burner air to allow red flame to enter wood combus- tion chamber about 6 inches.
7.Set the draft regulator on the chimney to .03” Water Col- umn negative to the chimney with burner operating at least 5 minutes.
8.Gas burner air should be adjusted with
9.Refer to burner manual for service tips.
FIG. 30
WAYNE MODEL P250 GAS BURNER