OIL BURNER MAINTENANCE

Maintenance

OIL BURNER MAINTENANCE

MAINTENANCE AT THE END OF THE HEATING SEASON:

1.Shut off electric current to burner at fuse panel.

2.If oil filter has not been cleaned recently, it should be removed and cleaned. (Consult instruction card furnished with fuel unit).

3.Oil storage tank should be kept filled to prevent water vapor from collecting. It is suggested the valve in the suction line be closed. Oil storage tank should be cleaned every 2 or 3 years. This is to remove any sediment or water that has collected in tank.

MAINTENANCE AT THE START OF THE HEATING SEASON:

1.It is advisable to have a service technician inspect and service your burner.

2.Heating plant, smoke pipe and chimney should be cleaned and checked for repairs.

3.It is advisable to have the entire electrical system inspected before putting the burner into operation. This is due to it standing idle for the summer months. This should include primary relay, limit control, thermostat.

Check the electrodes for carbon and cracks in insulators. Also check for corrosion on all terminals of the electrodes and transformer.

AIR FILTER MAINTENANCE:

Check and clean monthly. Change filter at least twice a year.

BLOWER MOTOR MAINTENANCE:

If motor has oil caps, oil twice yearly.

CAUTION:

The furnace has a high efficiency "fiber-type refractory" combustion chamber. Normal servicing of this unit does not require cleaning of the combustion chamber. Use EXTREME caution if it becomes necessary to work in the area of the combustion chamber. This pyrolite chamber should be checked monthly. Replace if damaged or worn.

FIG. 44

GUN ASSEMBLY ADJUSTMENT

The gun assembly can be adjusted in the slot of the fan housing. This is done by loosening the screw holding the slot cover in position. Adjust nozzle tip so it is located 7/8" behind the front face of the burner cone.

FIG. 45

48

Image 48
Contents POLAR/EAGLE Oil/Wood - Gas/WoodWarm Air Central Heating Furnaces LWO-112Oil Fired LWG-112Gas FiredFOR YOUR SAFETY For repair or replacement partsDANGER or call 1-800-358-0060TABLE OF CONTENTS PLAN YOUR INSTALLATIONINSTALLATION MAINTENANCESafety Statements STOP FOR SAFETYREAD THROUGH THE ENTIRE MANUAL extra safety precautions should be takenUnpack and Check Your Cartons INSPECT SHIPMENTPACKING LIST FIG.Furnace Features - Eagle I - Husky vMORE HEAT EXCHANGE SURFACEMEANS LESS HEAT UP THE CHIMNEY xTHE OIL OR GAS BURNER FIRES INTOyv x ~ w z u |Furnace Features - Eagle I - Husky Furnace Features - Eagle II - Polar uYUKONTROL SOLID-STATEzFIRE BRICK LINING EXTENDS w|z u Furnace Features - Eagle II - PolarSpecifications MODEL LWO-112OilInput rating 1.0 G.P.H. - 80 HPlan Your Installation Unit DimensionsPLAN YOUR INSTALLATION RULES FOR SAFE INSTALLATION AND OPERATIONBE SURE TO INSTALL DUCT WORK CLEARANCES TO COMBUSTIBLESWITH CLEARANCES SHOWN Plan Your InstallationTYPICAL INSTALLATION Plan Your InstallationBE INSTALLED WITH A METAL CONDENSATE PAN EVENT OF ELECTRIC POWER OR FURNACE FAN FAILUREInstallation DRAFT TUBE INSTALLATIONPLACE FURNACE SECONDARY AIR INTAKE COVERCUT AWAY VIEW BURNER COMBUSTION CHAMBER InstallationOIL BURNER INSTALLATION Install burner as followsInstallation Draft Tube AssemblyDRAFT DAMPER CONTROLInstallation FIG. 14-A FIG. 14-BSMOKE BAFFLES Installation INSTALLING THE HONEYWELL FAN/LIMIT CONTROLFan Limit Control Installation TYPICAL THERMOSTAT SETTINGSMOUNTING THE THERMOSTATS FIG.Installation FIG.FUEL TANKS AND FUEL LINES SINGLE LINE SYSTEMInstallation GAS PIPE SIZINGGAS PIPING FIG.Installation Field Controls Model WMO-1Safety SwitchFUME SENSOR GAS MODELS ONLY FIG.Installation ELECTRIC WIRINGWIRING THE FURNACE DS-103DAMPER CONTROL24 Volt Field Wiring OIL OR GAS AND WOOD HEATING ONLYOIL OR GAS AND WOOD HEATING WITH AIR CONDITIONING Installation CONNECTING SMOKE PIPEFIG. LESSER CLEARANCES TO COMBUSTIBLEACCURATELY ADJUST FLUE DRAFT A MANOMETER MUST BE USED TOInstallation MAKE THESE ADJUSTMENTS WHEN INSTALLINGInstallation PROPER CHIMNEYSCHOOSING A CHIMNEY Installation Installation COMBUSTION AIRFIG. FIG. FIGInstallation BTU Per Hour InputTo start the oil burner on a new installation Operating InstructionsOIL FIRING THE UNIT STARTING BURNER AFTER IGNITION FAILUREGas Firing the Unit To Start the Gas burner on new installationOperating Instructions FIG.Operating Instructions BEST WOOD TO BURNBTU’s EquivalentOperating Instructions STARTING WOOD FIRE WITH GAS OR OIL BURNERHAND FIRING WOOD HOW TO START A COAL FIRE Operating InstructionsWHAT SIZE COAL SHOULD I BURN? MAINTAINING A COAL FIREOperating Instructions OPERATING INSTRUCTIONS FOR BURNING COALON 1/2-INCHOPENING GRATES Optional Wiring Diagrams OIL AND WOOD HEATING ONLYOIL AND WOOD HEATING WITH A/C Wiring DiagramsGAS AND WOOD HEATING ONLY Wiring DiagramsGAS AND WOOD HEATING WITH A/C Wiring DiagramsMaintenance RECOVERING UNBURNED COALGRATE CARE -ASHREMOVAL ASH DISPOSALMaintenance CLEANING FURNACE AND CHIMNEY FLUE PIPESSMOKE PIPE, CHIMNEY AND SECONDARY HEAT EXCHANGER Secondary Heat Exchanger Eagle I - HuskyMaintenance FURNACE BLOWER ADJUSTMENTFIG. FIG. FIG. FIG. Maintenance DUCT WORK AND BLOWER SPEED ADJUSTMENTMaintenance TESTING INSTALLATIONS FOR EFFICIENCYFIG. Maintenance TEST PROCEDURE StepStep StepMaintenance FIREBRICK PLACEMENTFIREBRICK PLACEMENT Models LWO-112& LWG-112ONLY Fig. Lower RowMaintenance OIL BURNER MAINTENANCEMAINTENANCE AT THE END OF THE HEATING SEASON MAINTENANCE AT THE START OF THE HEATING SEASONMaintenance HOW TO PREVENT RUST AND CORROSIONDISPOSAL OF ASHES CREOSOTE-FORMATIONAND NEED FOR REMOVALMaintenance SMOKE IN THE FURNACE ROOMChimney causes FIG.Maintenance OVER HEATING WHEN BURNING SOLID FUEL ASYOUR PRIMARY SOURCE OF HEAT GAS OR OIL PART OF FURNACE TOO LARGE FOR THE HOMEExploded Views & Parts List EAGLE I - HUSKY MODELS LWO-112& LWG-112Exploded Views & Parts List Left HandRight Hand DescriptionEAGLE II - POLAR MODELS LWO-168& LWG-168 Exploded Views & Parts ListLeft Hand Shown Exploded Views & Parts ListKey No Left HandWAYNE MODEL MSR OIL BURNER Exploded Views & Parts ListGUN ASSEMBLY BURNER COMPONENTS WAYNE MODEL MSR Exploded Views & Parts ListMSR GUN ASSEMBLY DETAIL Part DescriptionWAYNE MODEL P250AF-DIN GAS BURNER Exploded Views & Parts ListBURNER COMPONENTS WAYNE MODEL P250AF-DIN Exploded Views & Parts ListPart Description Part NumberCIRCULATING FAN PERFORMANCE CURVE CHART CHART IS FOR DETERMINING MOTOR HORSEPOWER NEEDSMODELS LWO-112AND LWG-112 THIS CIRCULATING FAN PERFORMANCE CURVEMODELS LWO-168AND LWG-168 Exploded Views & Parts ListCIRCULATING FAN PERFORMANCE CURVE CHART CHART IS FOR DETERMINING MOTOR HORSEPOWER NEEDSTroubleshooting SERVICE HINTS- OILNotes HOW TO ORDER REPAIR PARTS Assembly Installation Operation Repair PartsYUKONEAGLE OWNERS MANUAL