MOUNTING THE THERMOSTATS

Installation

MOUNTING THE THERMOSTATS

The thermostats must be mounted on an interior centrally located wall. Place them away from direct sunlight, drafts, and approximately 5 feet above the floor. It is not required that they be level. Place them right next to each other. See Fig. 17.

Two Honeywell digital thermostats are furnished with all multi-fuel furnaces. The larger thermostat controls your gas, oil or electric, whichever back-up fuel you have. It offers one temperature setting for

when you want the burner to start. This is in the event your wood supply is inadequate in keeping your home at its temperature setting. It also has a night setback feature that allows you to keep lower temperatures at desired times. This thermostat also controls the air conditioning, if applicable.

The smaller thermostat controls the wood/coal room temperature. It does not have a night setback feature.

If you have no plans for air conditioning you will need a 3-wire thermostat cable from your furnace to your thermostat. If you intend to install air conditioning a 5-wire thermostat cable is required.

TYPICAL THERMOSTAT SETTINGS

Place 3 or 4 8” diameter logs into wood chamber. Set wood thermostat 5 degrees above room temperature. Set oil/gas thermostat 10 degrees above room temperature. Burner will then ignite and start the wood burning. When wood is adequately burning, reset gas/oil thermostat to 5 degrees below desired room temperature. Set wood thermostat to desired wood temperature. With the proper amount of wood in the firebox, the wood thermostat will keep the room temperature at the wood thermostat setting. When the wood is no longer able to keep up with the heating demands of your home and the temperature falls to the oil/gas thermostat setting, the burner will come on until that thermostat is satisfied.

FIG. 17

Honeywell Honeywell

Programmable Digital

Thermostat Thermostat

Questions? Visit www.yukon-eagle.com or call 1-800-358-0060

19

Image 19
Contents LWO-112Oil Fired LWG-112Gas Fired POLAR/EAGLEOil/Wood - Gas/Wood Warm Air Central Heating Furnacesor call 1-800-358-0060 FOR YOUR SAFETYFor repair or replacement parts DANGERMAINTENANCE TABLE OF CONTENTSPLAN YOUR INSTALLATION INSTALLATIONextra safety precautions should be taken Safety StatementsSTOP FOR SAFETY READ THROUGH THE ENTIRE MANUALFIG. Unpack and Check Your CartonsINSPECT SHIPMENT PACKING LISTxTHE OIL OR GAS BURNER FIRES INTO Furnace Features - Eagle I - HuskyvMORE HEAT EXCHANGE SURFACE MEANS LESS HEAT UP THE CHIMNEY~ w z u | yv xFurnace Features - Eagle I - Husky uYUKONTROL SOLID-STATE Furnace Features - Eagle II - PolarzFIRE BRICK LINING EXTENDS Furnace Features - Eagle II - Polar w|z u1.0 G.P.H. - 80 H SpecificationsMODEL LWO-112Oil Input ratingRULES FOR SAFE INSTALLATION AND OPERATION Plan Your InstallationUnit Dimensions PLAN YOUR INSTALLATIONPlan Your Installation BE SURE TO INSTALL DUCT WORKCLEARANCES TO COMBUSTIBLES WITH CLEARANCES SHOWNEVENT OF ELECTRIC POWER OR FURNACE FAN FAILURE TYPICAL INSTALLATIONPlan Your Installation BE INSTALLED WITH A METAL CONDENSATE PANSECONDARY AIR INTAKE COVER InstallationDRAFT TUBE INSTALLATION PLACE FURNACEInstall burner as follows CUT AWAY VIEW BURNER COMBUSTION CHAMBERInstallation OIL BURNER INSTALLATIONDAMPER CONTROL InstallationDraft Tube Assembly DRAFTFIG. 14-A FIG. 14-B InstallationSMOKE BAFFLES INSTALLING THE HONEYWELL FAN/LIMIT CONTROL InstallationFan Limit Control FIG. InstallationTYPICAL THERMOSTAT SETTINGS MOUNTING THE THERMOSTATSSINGLE LINE SYSTEM InstallationFIG. FUEL TANKS AND FUEL LINESFIG. InstallationGAS PIPE SIZING GAS PIPINGFIG. InstallationField Controls Model WMO-1Safety Switch FUME SENSOR GAS MODELS ONLYDS-103DAMPER CONTROL InstallationELECTRIC WIRING WIRING THE FURNACEOIL OR GAS AND WOOD HEATING ONLY 24 Volt Field WiringOIL OR GAS AND WOOD HEATING WITH AIR CONDITIONING LESSER CLEARANCES TO COMBUSTIBLE InstallationCONNECTING SMOKE PIPE FIG.MAKE THESE ADJUSTMENTS WHEN INSTALLING ACCURATELY ADJUST FLUE DRAFTA MANOMETER MUST BE USED TO InstallationPROPER CHIMNEYS InstallationCHOOSING A CHIMNEY Installation FIG. FIG InstallationCOMBUSTION AIR FIG.BTU Per Hour Input InstallationSTARTING BURNER AFTER IGNITION FAILURE To start the oil burner on a new installationOperating Instructions OIL FIRING THE UNITFIG. Gas Firing the UnitTo Start the Gas burner on new installation Operating InstructionsEquivalent Operating InstructionsBEST WOOD TO BURN BTU’sSTARTING WOOD FIRE WITH GAS OR OIL BURNER Operating InstructionsHAND FIRING WOOD MAINTAINING A COAL FIRE HOW TO START A COAL FIREOperating Instructions WHAT SIZE COAL SHOULD I BURN?OPERATING INSTRUCTIONS FOR BURNING COAL Operating InstructionsON 1/2-INCHOPENING GRATES Optional OIL AND WOOD HEATING ONLY Wiring DiagramsWiring Diagrams OIL AND WOOD HEATING WITH A/CWiring Diagrams GAS AND WOOD HEATING ONLYWiring Diagrams GAS AND WOOD HEATING WITH A/CASH DISPOSAL MaintenanceRECOVERING UNBURNED COAL GRATE CARE -ASHREMOVALSecondary Heat Exchanger Eagle I - Husky MaintenanceCLEANING FURNACE AND CHIMNEY FLUE PIPES SMOKE PIPE, CHIMNEY AND SECONDARY HEAT EXCHANGERFURNACE BLOWER ADJUSTMENT MaintenanceFIG. FIG. FIG. FIG. DUCT WORK AND BLOWER SPEED ADJUSTMENT MaintenanceTESTING INSTALLATIONS FOR EFFICIENCY MaintenanceFIG. Step MaintenanceTEST PROCEDURE Step StepModels LWO-112& LWG-112ONLY Fig. Lower Row MaintenanceFIREBRICK PLACEMENT FIREBRICK PLACEMENTMAINTENANCE AT THE START OF THE HEATING SEASON MaintenanceOIL BURNER MAINTENANCE MAINTENANCE AT THE END OF THE HEATING SEASONCREOSOTE-FORMATIONAND NEED FOR REMOVAL MaintenanceHOW TO PREVENT RUST AND CORROSION DISPOSAL OF ASHESFIG. MaintenanceSMOKE IN THE FURNACE ROOM Chimney causesGAS OR OIL PART OF FURNACE TOO LARGE FOR THE HOME MaintenanceOVER HEATING WHEN BURNING SOLID FUEL AS YOUR PRIMARY SOURCE OF HEATEAGLE I - HUSKY MODELS LWO-112& LWG-112 Exploded Views & Parts ListDescription Exploded Views & Parts ListLeft Hand Right HandExploded Views & Parts List EAGLE II - POLAR MODELS LWO-168& LWG-168Left Hand Left Hand ShownExploded Views & Parts List Key NoExploded Views & Parts List WAYNE MODEL MSR OIL BURNERGUN ASSEMBLY Part Description BURNER COMPONENTS WAYNE MODEL MSRExploded Views & Parts List MSR GUN ASSEMBLY DETAILExploded Views & Parts List WAYNE MODEL P250AF-DIN GAS BURNERPart Number BURNER COMPONENTS WAYNE MODEL P250AF-DINExploded Views & Parts List Part DescriptionTHIS CIRCULATING FAN PERFORMANCE CURVE CIRCULATING FAN PERFORMANCE CURVE CHARTCHART IS FOR DETERMINING MOTOR HORSEPOWER NEEDS MODELS LWO-112AND LWG-112CHART IS FOR DETERMINING MOTOR HORSEPOWER NEEDS MODELS LWO-168AND LWG-168Exploded Views & Parts List CIRCULATING FAN PERFORMANCE CURVE CHARTSERVICE HINTS- OIL TroubleshootingNotes OWNERS MANUAL HOW TO ORDER REPAIR PARTSAssembly Installation Operation Repair Parts YUKONEAGLE