Bryant 315AAV instruction manual Accessory List, Description Part Number

Page 59

Table 17 – Accessory List

DESCRIPTION

PART NUMBER

NOTES

 

 

 

 

FILCABXX0016

Filter cabinet 16” (406 mm) for 4” (102 mm) wide filter

 

 

 

Media Filter Cabinet

FILCABXX0020

Filter cabinet 20” (508 mm) for 4” (102 mm) wide filter

 

 

 

 

FILCABXX0024

Filter cabinet 24” (610 mm) for 4” (102 mm) wide filter

 

 

 

 

FILXXCAR0016

Filter Cartridge replacements for FILCAB media cabinet

 

 

 

Cartridge Media Filter

FILXXCAR0020

Filter Cartridge replacements for FILCAB media cabinet

 

 

 

 

FILXXCAR0024

Filter Cartridge replacements for FILCAB media cabinet

 

 

 

 

EXPXXUNV0016

16” (406 mm) Replacement Expandable Filter assembly

 

 

 

EZ Flex Media Filter with End Caps

EXPXXUNV0020

20” (508 mm) Replacement Expandable Filter assembly

 

 

 

 

EXPXXUNV0024

24” (610 mm) Replacement Expandable Filter assembly

 

 

 

 

EXPXXFIL0016

16” (406 mm) Replacement filter for EXPUNV assembly

 

 

 

Replacement EZ Flex Filter Media

EXPXXFIL0020

20” (508 mm) Replacement filter for EXPUNV assembly

 

 

 

 

EXPXXFIL0024

24” (610 mm) Replacement filter for EXPUNV assembly

 

 

 

 

KGAFR0401B14

Bottom return filter rack 14” (356 mm) casing

 

 

 

External Bottom Return Filter Rack

KGAFR0501B17

Bottom return filter rack 17” (432 mm) casing

 

 

KGAFR0601B21

Bottom return filter rack 21” (533 mm) casing

 

 

 

 

 

KGAFR0701B24

Bottom return filter rack 24” (610 mm) casing

 

 

 

External Side Return Filter Rack

KGAFR0801SRE

Ext. Side filter rack--- all casings--- includes filter

 

 

 

 

KGAWF1301UFR†

(1) unframed filter 16x25x3/4 (406x635x19 mm)

 

 

 

 

KGAWF1401UFR

(1) unframed filter 20x25x3/4 (508x635x19 mm)

 

 

 

Unframed Filter 3/4--- in. (19 mm)

KGAWF1501UFR

(1) unframed filter 24x25x3/4 (610x635x19 mm)

 

 

KGAWF1306UFR†

(6) unframed filter 16x25x3/4 (406x635x19 mm)

 

 

 

 

 

KGAWF1406UFR

(6) unframed filter 20x25x3/4 (508x635x19 mm)

 

 

 

 

KGAWF1506UFR

(6) unframed filter 24x25x3/4 (610x635x19 mm)

 

 

 

Flue Extension

KGAFE0112UPH

(12) vent extension 4” (102 mm) dia. x 3--- 1/2” (89 mm)

 

 

 

*Twinning Kit

KGATW0601HSI

Single or two stage PSC equipped units only

 

 

 

Combustible Floor Base

KGASB0201ALL

Adjustable floor base --- fits all casing sizes

 

 

 

Downflow Vent Guard

KGBVG0101DFG

Vent flue shield --- downflow venting outside casing

 

 

 

Vent Extension Kit

KGAVE0101DNH

Downflow, through casing vent extension

 

 

 

Chimney Adapter Kit

KGACA02014FC

Masonry chimney adapter 4” (102 mm)

 

 

KGACA02015FC

Masonry chimney adapter 5” (127 mm)

 

 

 

 

Natural--- to--- Propane Conversion Kit

KGANP4601ALL

Gas conversion natural to propane all

 

 

 

Propane--- to--- Natural Conversion Kit

KGAPN3901ALL

Gas conversion propane to natural all

 

 

 

Label Kit

KGALB0101KIT

Downflow orientation label replacement

 

 

 

**ECM Motor Simulator

KGASD0301FMS

ECM blower and inducer simulator --- variable speed units

 

 

 

**Advanced Product Monitor

KGAFP0301APM

PC software and hardware for Troubleshooting variable speed units

*Not for ECM or variable---speed ECM models

**Variable---speed ECM models only

315AAV

59

Image 59
Contents Electrostatic Discharge ESD Precautions CUT Hazard Safety ConsiderationsFurnace Reliability Hazard Clearances to Combustibles Codes and Standards Electrostatic Discharge ESD Precautions ProcedureIntroduction Location Dimensional Drawing Dimensions In. mmFIRE, Injury or Death Hazard Carbon Monoxide Poisoning / Component Damage HazardPersonal Injury AND/OR Property Damage Hazard Fire HazardLocation Relative to Cooling Equipment Carbon Monoxide Poisoning Hazard AIR for Combustion VentilationFurnace Corrosion Hazard Standard Method Air for Combustion, Ventilation, and Dilution for OutdoorsBottom Return Air Inlet InstallationUpflow Installation Combination of Indoor and Outdoor AirPlatform Furnace Support Downflow InstallationSuspended Furnace Support Floor and Plenum Opening Dimensions Roll-Out Protection General Requirements Opening Dimensions In. mmFilter Arrangement AIR DuctsDownflow Furnaces Supply Air ConnectionsUpflow and Horizontal Furnaces Horizontal Unit Suspension Typical Attic Installation Downflow Return Air Configurations and Restrictions CFM Air Delivery CFM With FilterFurnace Damage Hazard Return Air ConnectionsGAS Piping Fire or Explosion Hazard Maximum Capacity of PipeFurnace MAY not Operate Hazard WiringElectrical Connections Electrical Shock Hazard Electrical Shock and Fire HazardFire or Electrical Shock Hazard Electrical DataBox Relocation Venting BX Cable Installation in Furnace J-BoxAccessories Field Wiring Diagram Two-Stage Furnace with Single-Speed Air Conditioner General Venting RequirementsTwo-Stage Furnace with Two-Speed Air Condi Tioner See notes 1 and 2 on the page following these figures 315AAV Chimney Inspection Chart Burn Hazard Masonry Chimney RequirementAppliance Application Requirements Vent Height Additional Venting RequirementsUpflow Application Vent Elbow Up Horizontal Left Application Vent Elbow Left Horizontal Left Application Vent Elbow Up Venting Notes forFurnace Vent Orientation Furnace Input MIN. Vent START-UP, ADJUSTMENT, and Safety CheckSidewall Venting GeneralFire and Explosion Hazard Orifice HoleSetup Switch Switch Name Normal Description of USE Position Furnace Setup Switch DescriptionDerate Factor Altitude Derate Multiplier for U.S.AAltitude Percent Derate Multiplier Furnace Overheating Hazard Unit Damage Hazard315AAV Wiring Diagram Seconds G Size of Test Dial Gas Rate CU ft./hrSpecific Gravity of Natural GAS Altitude Range BTUH/CU FT AltitudeRange BTUH/CU Altitude RangeAT Altitude Electrical Operation Hazard Service and Maintenance ProceduresEnvironmental Hazard Electrical SHOCK, Fire or Explosion HazardComponent Self-Test Electrical Controls and WiringCarbon Monoxide Poisoning and Fire Hazard Care and Maintenance Fire or Explosion HazardCleaning and/or Replacing Air Filter Media cabinet filter proceduresFollowing steps should be performed by a qualified Cleaning Heat ExchangerService agency Filter Size Information In. mmIgniter Position Side View Sequence of Operation Inducer Prepurge Period Cooling A/C or Continuous-Fan CF Airflow Selection ChartSingle-Speed Cooling Single-Stage Thermostat and Two-Speed Cooling Adaptive ModeContinuous Blower Mode Thermidistat ModeSuper-Dehumidify Mode Component test TroubleshootingHeat pump Troubleshooting Guide Adapter Kit Werblo Modelinvalid Orselection Description Part Number Accessory ListParts Replacement Information Guide