Bryant 340MAV instruction manual Ð37Ð

Page 37

 

 

TABLE 8ÐMODEL 340MAV ORIFICE SIZE AND MANIFOLD PRESSURE FOR CORRECT INPUT

Continued

 

 

 

 

FOR USE WITH 040 THROUGH 120 SIZE FURNACES ONLY

 

 

 

 

 

 

(TABULATED DATA BASED ON 20,000 BTUH PER BURNER, DERATED 2% FOR EACH 1000 FT ABOVE SEA LEVEL)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

 

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

625

43

 

3.8

42

 

3.3

42

 

3.4

42

 

3.5

42

 

3.6

 

 

 

650

43

 

3.5

43

 

3.7

43

 

3.8

42

 

3.2

42

 

3.3

Only

 

 

675

44

 

3.8

43

 

3.4

43

 

3.5

43

 

3.6

43

 

3.7

 

7001

700

44

 

3.5

44

 

3.6

44

 

3.8

43

 

3.4

43

 

3.5

 

 

 

 

 

 

 

U.S.A.

 

 

725

44

 

3.3

44

 

3.4

44

 

3.5

44

 

3.6

44

 

3.7

 

to

775

45

 

3.5

45

 

3.6

45

 

3.7

45

 

3.8

44

 

3.3

 

 

750

45

 

3.7

45

 

3.8

44

 

3.3

44

 

3.4

44

 

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8000

800

45

 

3.3

45

 

3.4

45

 

3.5

45

 

3.6

45

 

3.7

 

 

 

825

45

 

3.1

45

 

3.2

45

 

3.3

45

 

3.4

45

 

3.5

 

 

 

850

45

 

2.9

45

 

3.0

45

 

3.1

45

 

3.2

45

 

3.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

 

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

600

43

 

3.8

42

 

3.3

42

 

3.4

42

 

3.5

42

 

3.6

 

 

 

625

43

 

3.5

43

 

3.6

43

 

3.8

42

 

3.2

42

 

3.3

Only

 

8001

650

44

 

3.7

43

 

3.4

43

 

3.5

43

 

3.6

43

 

3.7

 

 

675

44

 

3.5

44

 

3.6

44

 

3.7

44

 

3.8

43

 

3.4

 

 

 

 

 

 

 

 

U.S.A.

 

to

700

44

 

3.2

44

 

3.3

44

 

3.4

44

 

3.6

44

 

3.7

 

 

725

45

 

3.6

45

 

3.8

44

 

3.2

44

 

3.3

44

 

3.4

 

 

 

 

 

 

 

 

 

 

9000

750

45

 

3.4

45

 

3.5

45

 

3.6

45

 

3.8

44

 

3.2

 

 

 

775

45

 

3.2

45

 

3.3

45

 

3.4

45

 

3.5

45

 

3.6

 

 

 

800

45

 

3.0

45

 

3.1

45

 

3.2

45

 

3.3

45

 

3.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALTITUDE

AVG GAS

 

 

 

 

 

SPECIFIC GRAVITY OF NATURAL GAS

 

 

 

 

HEAT VALUE

 

0.58

 

0.60

 

0.62

 

0.64

 

0.66

 

 

RANGE

 

 

 

 

 

 

 

(FT)

AT ALTITUDE

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

Orifice

 

Manifold

 

 

(BTU/CU FT)

 

 

 

 

 

 

 

 

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

No.

 

Pressure

 

 

 

575

43

 

3.8

42

 

3.2

42

 

3.3

42

 

3.5

42

 

3.6

 

 

 

600

43

 

3.5

43

 

3.6

43

 

3.7

42

 

3.2

42

 

3.3

Only

 

9001

625

44

 

3.7

44

 

3.8

43

 

3.5

43

 

3.6

43

 

3.7

 

 

650

44

 

3.4

44

 

3.5

44

 

3.7

44

 

3.8

43

 

3.4

 

 

 

 

 

 

 

 

U.S.A.

 

to

675

45

 

3.8

44

 

3.3

44

 

3.4

44

 

3.5

44

 

3.6

 

 

700

45

 

3.6

45

 

3.7

45

 

3.8

44

 

3.3

44

 

3.4

 

 

 

 

 

 

 

 

 

 

10,000

725

45

 

3.3

45

 

3.4

45

 

3.6

45

 

3.7

45

 

3.8

 

 

 

750

45

 

3.1

45

 

3.2

45

 

3.3

45

 

3.4

45

 

3.5

 

 

 

775

45

 

2.9

45

 

3.0

45

 

3.1

45

 

3.2

45

 

3.3

Ð37Ð

Image 37 Contents
ÐMultipoise Orientations Ð1ÐÐ2Ð DimensionsUnit Size Electrostatic Discharge ESD Precautions Safety ConsiderationsMinimum Inches Clearance to Combustible Construction → ÐClearances to CombustiblesApplications General IntroductionII. Upflow Applications Condensate Trap Location Factory-Shipped OrientationCondensate Trap Location Alternate Upflow Orientation Ð5ÐÐ6Ð Pressure Switch TubingIII Downflow Applications Condensate Trap Freeze ProtectionCondensate Trap Location Condensate Trap TubingÐ8Ð IV. Horizontal Left SUPPLY-AIR Discharge ApplicationsConstruct a Working Platform Ð9ÐHorizontal Right SUPPLY-AIR Discharge Applications ÐAttic Location and Working Platform Location → ÐHorizontal Right Tube ConfigurationIII. Hazardous Locations II. Furnace Location Relative to Cooling Equipment→ II. Installation in Upflow or Downflow Applications Installation Leveling Legs if DesiredFurnace Plenum Opening Floor Opening Casing Ðopening DimensionsWidth ÐDuct Flanges III. Installation in Horizontal ApplicationsÐfilter Information IV. Filter ArrangementBottom Closure Panel VI. GAS Piping WiringÐmaximum Capacity of Pipe Electrical ConnectionsII -V Wiring → ÐHeating and Cooling Application Wiring DiagramÐWiring Diagram Ðelectrical Data III. AccessoriesAmps Gage AmpsRemoval of Existing Furnaces from Common Vent Systems Direct VentingII. COMBUSTION-AIR and Vent Piping GeneralExample Combustion-Air and Vent Pipe DiameterCombustion-Air and Vent Pipe Attachment ÐShort Vent 5 to 8 Ft System COMBUSTION-AIR Intake Housing Plug Fitting2001 to Ðmaximum Allowable Pipe Length FT4001 to 5000³ Ðmaximum Allowable Pipe Length FT8001 to 9000³ Vent Extension PipeTwo-Pipe Termination Kit Extended Exposed Sidewall PipesÐRoof Termination Preferred IV. Multiventing and Vent Terminations Concentric Vent/Air Termination KitCondensate Drain General II. ApplicationÐConcentric Vent and Combustion-Air Sequence of Operation Heating ModeIII. Condensate Drain Protection III. Continuous Blower Mode II. Cooling ModeIV. Heat Pump Mode Component Test II. Prime Condensate Trap with Water START-UP Procedures GeneralIII. Purge GAS Lines IV. AdjustmentsSet Gas Input Rate BTU/CU FT Ð36Ð Ð37Ð Ð38Ð Ð39Ð United States Set Temperature RiseÐaltitude Derate Multiplier for U.S.A CanadaII. Check Pressure Switch Check Safety Controls Check Primary Limit ControlChecklist Ðspeed SelectorCHECKLISTÐSTART-UP ChecklistðinstallationLoad Calculation Combustion and Vent PipingÐ43Ð Service Training
Related manuals
Manual 12 pages 2.16 Kb Manual 48 pages 30.25 Kb