Bryant 345MAV instruction manual Ð2Ð, Dimensions, → ÐDimensional Drawing, Unit Size

Page 2

 

 

26 1516"

 

 

 

 

 

 

26 14"

 

 

 

AIRFLOW

 

 

24 12"

 

 

 

 

 

 

 

 

 

 

 

22 516"

 

 

 

A

 

 

 

 

 

 

 

 

2-IN. COMBUSTION-

 

 

13/16"

D

 

 

AIR CONN

CONDENSATE DRAIN

 

OUTLET

 

 

 

TRAP LOCATION

 

 

 

 

 

 

 

 

 

 

 

(DOWNFLOW &

 

 

 

 

 

 

HORIZONTAL LEFT)

 

 

 

 

 

 

78-IN. DIA

 

 

 

 

 

12-IN. DIA

POWER CONN

 

 

 

 

 

GAS CONN

 

 

 

 

 

 

2-IN. VENT CONN

 

 

 

 

 

 

 

 

 

33 14"

 

 

 

 

 

 

TYP

 

 

 

1

 

 

32 58"

 

 

 

2-IN. DIA THERMOSTAT

 

 

TYP

 

 

 

ENTRY

 

 

 

 

 

78-IN. DIA

 

30 1316"

 

 

 

22 1116"

 

 

 

 

 

 

ACCESSORY

 

29 1116"

 

 

 

 

POWER ENTRY

 

27 58" TYP

 

 

 

 

CONDENSATE

 

 

 

 

 

 

27 916"

 

 

 

 

DRAIN TRAP

 

 

 

 

 

LOCATION

 

TYP

 

 

 

 

(ALTERNATE

24

12"

 

 

 

 

UPFLOW)

 

 

14 12"

SIDE INLET

 

 

 

 

17 516"

 

 

 

TYP

 

 

 

 

 

 

9 716"

 

 

 

 

 

 

TYP

 

 

 

Ð2Ð

114"

 

 

 

 

INLET

 

CONDENSATE

 

 

 

1"

23 14" TYP

 

11/16"

E

 

DRAIN LOCATION

 

 

SIDE INLET

 

 

 

 

(UPFLOW)

 

 

 

 

 

 

 

 

 

 

 

26 1516" TYP

 

 

 

 

 

 

28 12"

 

 

 

26 1516"

 

 

 

26 14"

 

 

 

22 516"

 

13/16"

916"

19"

1316"

 

TYP

 

58"

 

 

OUTLET

 

 

 

CONDENSATE DRAIN

2-IN. COMBUSTION-

 

 

TRAP LOCATION

 

 

AIR CONN

 

 

(DOWNFLOW &

516"

HORIZONTAL RIGHT)

12-IN. DIA

 

 

OR ALTERNATE

 

12-IN. DIA GAS CONN

GAS CONN

 

 

 

78-IN. DIA

 

 

 

POWER CONN

 

 

 

12-IN. DIA

 

 

 

THERMOSTAT ENTRY

39 78"

 

30 12"

2-IN. VENT CONN

 

 

 

 

 

22 1116"

 

 

18 14"

SIDE INLET

 

 

 

 

 

 

 

1"

 

CONDENSATE

22 14" TYP

716"

11/16"

DRAIN LOCATION

 

(UPFLOW)

24 316"

1116"

 

DIMPLE LOCATORS

 

BOTTOM INLET

 

 

FOR HORIZONTAL

 

 

 

HANGING

 

 

NOTES: 1. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.

2.Minimum return-air opening at furnace:

a.For 800 CFM–16-in. round or 141/2 x 12-in. rectangle.

b.For 1200 CFM–20-in. round or 141/2 x 191/2-in. rectangle.

c.For 1600 CFM–22-in. round or 141/2 x 231/4-in. rectangle.

d.For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.

A99112

DIMENSIONS (IN.)

UNIT SIZE

A

D

E

024040

17-1/2

15-7/8

16

036040

17-1/2

15-7/8

16

024060

17-1/2

15-7/8

16

036060

17-1/2

15-7/8

16

048060

17-1/2

15-7/8

16

036080

17-1/2

15-7/8

16

048080

17-1/2

15-7/8

16

060080

21

19-3/8

19-1/2

048100

21

19-3/8

19-1/2

060100

21

19-3/8

19-1/2

060120

24-1/2

22-7/8

23

 

 

 

 

Fig. 2ÐDimensional Drawing

Image 2
Contents Electrostatic Discharge ESD Precautions Ð1ÐÐ2Ð Dimensions→ ÐDimensional Drawing Unit SizeMinimum Inches Clearance to Combustible Construction Safety ConsiderationsElectrostatic Discharge ESD Precautions → ÐClearances to CombustiblesII. Upflow Applications IntroductionApplications General Condensate Trap Location Factory-Shipped OrientationÐ5Ð Condensate Trap Location Alternate Upflow OrientationCondensate Trap Field Drain Attachment Pressure Switch TubingÐ6Ð Condensate Trap Location Condensate Trap Freeze ProtectionIII. Downflow Applications Condensate Trap TubingIV. Horizontal Left SUPPLY-AIR Discharge Applications Ð8ÐÐ9Ð Horizontal Right SUPPLY-AIR Discharge ApplicationsConstruct a Working Platform ÐAttic Location and Working Platform Front Upflow or Downflow Horizontal II. Furnace Location Relative to Cooling Equipment II. Unconfined Space III. Hazardous LocationsAIR for Combustion and Ventilation General III. Confined SpaceCombustion AIR from Outdoors Through Horizontal Ducts Installation Leveling Legs if DesiredCombustion AIR from Outdoors Through Vertical Ducts Furnace Casing Width II. Installation on a Concrete SlabOpening Dimensions General Requirements IV. Installation in Horizontal ApplicationsAIR Ducts Ductwork acoustical treatmentÐfilter Information Return Air ConnectionsVI. Filter Arrangement VII. Bottom Closure PanelVIII. GAS Piping 171⁄2-IN. Wide Casings onlyNominal Length of Pipe FT Iron Internal Diameter Size Ðmaximum Capacity of Pipe CU FT PER HRElectrical Connections Ðelectrical Data WiringLength FT³ CKT BKR Amps Phase Amps SizeÐWiring Diagram Venting II -V WiringIII. Accessories Removal of Existing Furnaces from Common Vent SystemsCombustion Air Pipe II. COMBUSTION-AIR and Vent PipingGeneral ÐCombustion-Air Inlet Pipe Assembly 4001 to 5000² Ðmaximum Allowable Vent Pipe Length FT3001 to 6001 to 7000² Ðmaximum Allowable Vent Pipe Length FT5001 to 6000² 7001 to 8000²ÐShort Vent 5 to 8 Ft System 9001 to 10,000²Vent Extension Pipe 040 060 080 100 120Condensate Drain General III. Vent TerminationIV. Multiventing Ðvent Pipe Termination ClearancesÐRoof Termination Preferred III. Continuous Blower Mode Heating ModeII. Cooling Mode IV. Heat Pump ModeComponent Test Sequence START-UP Procedures GeneralComponent Test II. Prime Condensate Trap with WaterIII. Purge GAS Lines → ÐInducer Housing Drain TubeIV. Adjustments Set Gas Input RateBTU/CU FT Altitude5000 Only4001 Only 50018000 7001775 Only 8001Altitude Derate Multiplier Factor for U.S.A Ðaltitude Derate Multiplier for U.S.AExample Ðgas Rate CU FT/HR Set Temperature RiseBlower Off Delay Heat Mode ±SPEED SelectorChecklist Check Safety Controls Check Primary Limit ControlII. Check Pressure Switch Load Calculation ChecklistðinstallationCHECKLISTÐSTART-UP Vent Piping
Related manuals
Manual 12 pages 26.52 Kb Manual 12 pages 34 Kb

345MAV specifications

The Bryant 345MAV is a premier choice in the realm of residential heating and cooling systems, encapsulating advanced technologies, high efficiency, and remarkable performance. Designed for homeowners seeking reliability and comfort, this model exemplifies modern HVAC (Heating, Ventilation, and Air Conditioning) innovations.

One standout feature of the Bryant 345MAV is its impressive energy efficiency. With a high SEER (Seasonal Energy Efficiency Ratio) rating, it operates at peak levels while consuming less energy. This not only reduces utility bills but also supports environmental sustainability, making it an ideal selection for eco-conscious consumers. The model employs variable-speed technology, which allows the system to adjust its output based on current heating and cooling needs. As a result, it provides consistent indoor comfort while minimizing temperature fluctuations.

The Bryant 345MAV incorporates advanced refrigerant technologies designed for optimal performance. It uses R-410A refrigerant, which is known for its lower environmental impact compared to traditional refrigerants like R-22. This environmentally friendly aspect aligns with regulations aimed at reducing ozone depletion, thereby promoting a greener approach to heating and cooling.

Reliability is another hallmark of the Bryant 345MAV. Engineered with precision, this model features a durable build designed to withstand varying weather conditions. The system is equipped with a robust compressor that is engineered for longevity and minimal noise during operation. Homeowners will appreciate the quiet performance of the 345MAV, ensuring peace in their living spaces.

Comfort also extends to the user experience with the inclusion of a smart thermostat option. This integration allows homeowners to manage their heating and cooling systems remotely, enhancing convenience and control. Programmable settings can optimize energy use based on individual schedules, facilitating both comfort and savings.

In summary, the Bryant 345MAV is a top-tier solution for residential climate control, blending energy efficiency, innovative technology, and unmatched reliability. With its variable-speed operation, environmentally friendly refrigerant, and smart features, the 345MAV represents a significant advancement in the HVAC field. Homeowners investing in this model can expect a system that not only meets their heating and cooling needs but exceeds them in terms of efficiency and comfort.