Contents
JO and later design sequence
Models
Introduction
Hazard Identification
Special Note on Refrigeration Emissions
HazardousVoltage w/Capacitors
Contents
Features and Benefits
Refrigerant Handling Procedures
Modular Series Self-Contained Unit Components
Installation information
Unit Nameplate
Model Number Description Scwg
Model Number Description
Digit 31 Compressor ServiceValves
Digit 22 Unit Finish
Digit
Digit 24 Unit Connection
Self-Contained Ship-WithAccessory Model Number Description
Model Number Description Pswg
After-ShipmentAccessory Model Number
Receiving and Handling
Shipping Package
Installation Preparation
ServiceAccess
Table I-PC-1. Service and code clearance requirements
Section
TopView CCRC/CIRC 20, 29
Rigging and Unit Handling
Lifting Equipment Capacity
Unit Handling Procedure
Figure I-PC-7.Assembled modular unit proper rigging
Split-Apart Unit Assembly
IntelliPak UnitsUCM Only
Remove panels FML, FMM, and FMR
Units with Thermostat Only
Figure I-PC-9 How to assemble the split apart modular unit
Pre-Installation Checklist
Skid Removal
External Unit Isolation
Dimensions
Weights
SCWG/SIWG Dimensions,
Left-side view
SCRG/SIRG Dimensions,
SCRG/SIRGWeight, lbs
Left-side View Right-side view Top view
Dimensions Weights
Detail Dimensions,
CCRC/CIRC Air-cooled condenser dimensions & weight, in-lbs
CCRC/CIRC -Air-Cooled Condenser
CCRC/CIRC Electrical connections,
CCRC/CIRC Refrigerant connections,
Hot water coil dimensions & weight, in-lbs
Hot Water Coil
Steam coil dimensions, in-lbs
Steam Coil
Electric heat coil dimensions & weight, in-lbs
Electric Heat Coil
Flexible Horizontal Discharge Plenum
Waterside economizer weight, in-lbs
Waterside Economizer
Airside economizer dimensions & weight, in-lbs
Airside Economizer
Detail a Detail B
Dimensions Weights VFD
Variable Frequency Drive Option VFD
Control and LineVoltage
Result in death or serious injury Mounting Requirements
Electrical Installation Procedure
VFD with bypass dimensions,
Variable Frequency Drive with Bypass
Mechanical Specifications
Duct Connections
Water Piping
Hazardous Voltage w/Capaci- tors
Waterside Piping Arrangements
Table I-MR-1. Water Connection Sizes
Brazing Procedures
Refrigerant Piping Air-Cooled Units Only
Hazard of Explosion and Deadly Gases
Unit Wiring Diagrams
Supply PowerWiring
Live Electrical Components
Equipment Damage
Selection Procedures
Installation requirements
Pre-Startup Procedures
Supply Fan Isolators
Shipping bracket
Figure I-PR-3. Correct plenum insulation placement
Airside Economizer Installation
Unit Installation
Field Wiring Connections
Unit Handling
Static PressureTransducer Installation VAV units only
Installing theTransducer
Transducer Location
Waterside Economizer Installation Procedure
Figure I-PR-7. Installing the waterside economizer
Tubing assemblies for waterside econo Mizer left-hand piping
Waterside Economizer Ship-Separate Parts List
Hydronic Coil Installation
Installation Procedure
Unit Structural Integrity
Electric Heat Installation
Electric Heat CoilWiring Procedure
Table I-PR-2.Available Electric Heat kW
Standard with All IntelliPak Units
Zone Sensor Options for IntelliPak Control Units
CV Unit Zone Sensor Options
BAYSENS077* Description
CV andVAV Unit Zone Sensor Options
VAV Unit Zone Sensor Option
BAYSENS074 Description
BAYSENS073 Description
Zone Sensor Installation
Wiring
Mounting Location
Mounting the Subbase
Right
Mounting Directly to the Wall Mounting to Junction Box
ConstantVolume Zone Sensor BAYSENS019 Description
Variable AirVolume Zone Sensor BAYSENS020B Description
Programmable Zone Sensors
Programmable Zone Sensor Installation
Airflows from adjacent zones or other units
Time Clock Installation
Time Clock Installation Checklist
Wiring theTimeclock
Time Clock Option
Remote Human Interface Panel Installation
Human Interface HI Panel
Remote Human Interface Panel
Location Recommendations
Procedure
Mounting the Remote Human Interface RHI Panel
Wall Mounting the RHI Panel
Pre-startup
Wiring the Remote Human Interface
LowVoltage AC FieldWiring Connections
Communication Link ShieldedTwisted PairWiring
Interprocessor Communication Bridge ModuleWiring
Connecting toTracer Summit
Pre-Startup Checklist
Installation programming
Programmable Zone Sensor Options
Heat supply air Cool supply air Warmup temperature
During Programming Indicates
Keypad Operation
Temporary Manual Override
Time Button
Keypad Lockout
Up and Down Button Arrows
Temporary Override Run Mode
Figure I-P-6.Temporary manual override menu screen
Figure I-P-7.Temporary manual override run mode screen
Table I-P-1. Zone sensor BAYSENS019 option menu settings
Remote Panel Indicator Signals From UCM to ZSM
Intelligent Copy
To use Intelligent Copy
Off Flashing
Icon Descriptions
Figure I-P-9.BAYSENS019 complete icon display
Figure I-P-10.BAYSENS020 complete icon display
Setting theTime
Programming theTime Clock Option
Programming
To review and change programs
Installation startup
Unit Startup Procedures
Pre-Startup Checklist
Compressor Damage
Startup Log
Evaporator
Compressor Amp Draw
Water Cooled Units
Air Cooled Units
Points List RTM Module
Points List Gbas Module
Points List Ecem Module
Points List -TracerTMLCI-I Module
Unit Control Components
RTM Module Board Standard on all Units
Table O-GI-2. RTM sensor resistance vs. temperature
VAV Box Option
Table O-GI-3. RTM setpoint analog inputs
Human Interface Module Standard on all Units
Heat Module
Ventilation Override Module VOM Option
Purge sequence D
Supply fan on Supply fan VFD on if equipped
Generic BuildingAutomation System Module Option
Table O-GI-6. Gbas analog input setpoints
Table O-GI-7. Gbas input voltage corresponding setpoints
Waterside Components
Figure O-GI-3. Basic water piping, constant water flow
UnitAirside Components
General Operation information
Airside Economizer Interface with Comparative Enthalpy
Air-Cooled Condensers
Input Devices and System Functions
ProperWaterTreatment
Return AirTemperature Sensor
Supply Air Temperature Sensor
Supply Airflow Proving Switches
Filter Switch
Operation operation
Control Sequences Operation
Unoccupied Sequence of Operation
Tracer Summit System
Morning Warmup
Cycling Capacity Morning Warmup MWU
Timed Override Activation ICS
Occupied Sequence
Supply Air Setpoint Reset VAV Units Only
Mechanical Cooling
Water-Cooled Units Only
Electric Heat
Compressors
Compressor Lead/Lag Operation
Table O-SO-1. Compressor Stages
Step Control
Evaporator Coil Frost Protection
Table O-SO-2. Pressure cutouts
Service Valve Option
Operation
Maintenance information
Table M-GI-1. SCWG/SIWG/SCRG/SIRG General Maintenance Data
Maintenance procedures
Maintenance Procedures
Air Filters
Inspecting and Cleaning the Drain Pan
Inspecting and Cleaning the Fan
Remove all standing water
Supply Fan
Variable Frequency Drive VFD
Fan Drive
Fan Bearings
Table M-MP-1. Baldor Fan Bearing Lubrication Schedule
Table M-MP-2.AO Smith Bearing Lubrication Schedule
Table M-MP-3. Compatible Fan Bearing Grease
Fan BeltTension
Deflection = belt span/64
Table M-MP-4. Fan shaft bearing torques
Adjusting BeltTension
Belt
Refrigerant System
Confined Space Hazards
Refrigerant Evacuation
Refrigerant LeakTesting
Motor Winding Damage
Use of Pressure Regulator Valves Gauges
R407c
Maintenance
Coil Fin Cleaning
Proper Coil CleaningAgent
Inlet GuideVanes
Coil Freezeup
Chemical Cleaning of Condenser and Economizer Coil
Flow Switch Maintenance
Cleaning the Flow Switch
Piping Components
Maintenance Periodic Checklists
Monthly Checklist
Semi-Annual Maintenance
Annual Maintenance
Check the zone thermostat settings
Operating Procedures
Common Unit Problems and Solutions
System Checks
Maintenance diagnostics
Diagnostics
Heat Module Auxilliary Temperature Sensor Fail
Emergency Stop
Entering Cond WaterTemp Sensor Fail
Entering Water Temp Sensor Fail
Mode Input Failure
Low Air Temp Limit Trip
Low Pressure Control Open Circuit 1, 2, 3, or
MCM Communications Failure
NSB Panel ZoneTemperature Sensor Failure
Check Field/unit wiring between RTM and NSB Panel
Humidity Sensor Failure
Temp. Sensor Failure
RTM Data Storage Error
RTM Zone Sensor Failure
Supply Fan VFD Bypass Enabled
ProblemThe LCI-I has lost communication withTracer Summit
Supply Fan Failure
LCI-I Module Comm Failure
Render all HI keystrokes ineffective
VOM Communications Failure
WSM Communications Fail
WSM Mixed AirTemp Sensor Fail
Water Flow Fail
114
115