Honeywell LYNXR-2 manual Securing the Premises, Checking System Status

Page 15

SECURING THE PREMISES

Checking System Status

General Information

Before arming your system, all protected doors, windows, and other protection zones must be closed or

bypassed (see the BYPASSING PROTECTION section). Pressing the

STATUS

key will announce all

zones that are faulted, as well as any other abnormal system condition, making it easier for you to secure any open zones.

READY LIGHT: The green READY indicator on the keypad will be lit if the system is ready to be armed. If blinking, the system is not ready.

Press the

STATUS

Key

Press the

STATUS

key once to announce the general status of the system.

Depending on the current state of the system the following phrases may be heard:

disarmed, ready to arm [message] [check system] disarmed, [not ready to arm], [message]

armed [away] [stay] [instant] [check system] [message]

NOTE: The phrases shown in brackets are variable, and are announced only if appropriate in the current state of the system.

Press the STATUS key a second timeto announce specific system status.

Depending on the current state of the system the following phrases may be heard:

fire alarm [zone voice descriptors]

carbon monoxide alarm [zone voice descriptors] alarm [zone voice descriptors]

fire fault [zone voice descriptors]

carbon monoxide fault [zone voice descriptors] fault [zone voice descriptors]

low battery

[zone voice descriptor]

system low battery

check system

AC loss

 

zones bypassed

chime

(second depression must be made within 10 seconds of the first)

VOLUME LEVEL: The volume level of system announcements can be increased or decreased. Refer to the MESSAGE RECORDING/PLAYBACK section for the procedure.

System Can Be Armed

The READY LED will be lit once all protection zones have been closed or bypassed. You may now arm the system as usual.

– 15 –

Image 15
Contents LYNXR-2 Series Security System Page Table of Contents Page System Overview FeaturesLYNXR-2SIA False Alarm Prevention Features General Operation Two-Way Voice Feature Quick View of System Functions To remotely activate X10 devices 07 To turn Test mode onTo turn Test mode off To remotely activate X10 devicesGeneral About the Master Keypad2ARMED 3READY Master Keypad DefinitionsLights on / Lights OFF Keys Turns LED Meanings About the Display and IndicatorsChecking System Status Securing the PremisesExit Delay Restart/Reset Arming in Stay ModeArming In Away Mode Restarting Exit Delay While System ArmedQuick Arming Auto Stay FeatureArming the System with No Delay To arm with no Delay if Quick Arm is activeLYNXR-2SIA Exit/Entry Delay Times Entry/Exit DelaysExit Delay Entry DelayMemory of Alarm To disarm the system and silence burglary alarmsDisarming the System Displaying Bypassed Zones Bypassing Protection ZonesBypassing Individual Zones Forced BypassPanic Keys / Chime Mode Chime ModePanic Keys Code Format Paging FeatureUser Functions Automatic PagingReminder Announcements Follow Me Announcement FeatureFollow Me Reminder and System Announcements System AnnouncementsTo delete Follow Me reminder telephone number To program Follow Me reminder telephone numberTo deactivate X10 devices 07 Device DescriptionsDeleting Messages Message Recording/Playback/Volume ControlRecording a Message Message PlaybackAdjusting the Volume To adjust message playback/system announcement volumeTo restore announcement sounding Function + AUX Function Defining the AUX FunctionPerforming the AUX function Month Clock/CalendarHour MinuteYear DayScheduling User Interface Schedule number = the value that was last stored in the memoryEnd Time minute Entry Event Comment Event Identifier EntriesEntry Day Day of Week EntriesRemote Phone Control Feature Using Remote Phone Control FeatureEnter Remote Phone Control Commands To remotely disarm system To remotely arm in Away modeTo remotely Bypass zones Using the Speaker Phone Feature Speaker Phone FeatureEntering # + Remote Services Silencing a Fire Alarm General InformationCase of Fire Living Room Bedroom Fire Alarm SystemEmergency Evacuation System Functions Security CodesTo Add/Delete a User or Change a Users Code Testing the System to be conducted weekly Entering Test ModeExit Test Mode Trouble Messages Typical Trouble Condition DisplaysRoutine Care Low Battery Conditions in Wireless Sensors Changing the LYNXR-2 Series System BatteryMaintaining your system Sound Cause Display Announcement Summary of Audible NotificationAdditional Announcements Industry Canada Federal Communications Commission FCC Part 15 StatementRinger Equivalence Number Notice Federal Communications Commission FCC PartEvent of Telephone Operational Problems Servicing Information Page Notifies Insert B = Burglary, F = Fire Owners Insurance Premium Credit RequestOwners Insurance Premium Credit Request Limitations of this Alarm System Page Page Page Index No delay Pager ONE Year Limited Warranty ÊK15012yŠ

LYNXR-2 specifications

The Honeywell LYNXR-2 is an advanced wireless security system designed for residential and light commercial applications. Recognized for its user-friendly interface, the LYNXR-2 combines cutting-edge technology with essential security features, making it a popular choice among homeowners seeking peace of mind.

One of the primary characteristics of the LYNXR-2 is its sleek, modern design, which includes a large, easy-to-read touchscreen display. This intuitive interface allows users to manage their security system with minimal effort. From arming and disarming the system to viewing alerts, the touchscreen simplifies the interaction for users of all ages.

The LYNXR-2 employs Honeywell’s innovative technology, which integrates both security and home automation functionalities. This powerful system supports a wide range of wireless sensors, including door/window contacts, motion detectors, and smoke detectors. The flexibility of wireless technology means users can easily expand their security coverage without the need for complicated wiring.

Another notable feature of the LYNXR-2 is its built-in Z-Wave technology. This allows for seamless integration with smart home devices, enabling users to control lights, locks, and thermostats through the same interface. Home automation capabilities enhance security further by allowing users to program their system to perform specific actions, such as turning on lights when entering a home.

The LYNXR-2 system also offers robust communication features. It comes equipped with a cellular backup, ensuring that users remain connected to monitoring services even during power outages or if the phone line is cut. Additionally, the system supports both IP and cellular connectivity, providing flexibility in how users choose to connect their systems to monitoring services.

For those looking for added functionality, the LYNXR-2 can be easily integrated with Honeywell’s Total Connect Remote Services. This allows users to monitor and control their security system remotely through a smartphone or tablet, providing real-time notifications and updates on system status.

In summary, the Honeywell LYNXR-2 stands out for its combination of user-friendly features, advanced technologies, and extensive security and automation capabilities. It is an ideal solution for individuals seeking a reliable, scalable, and easy-to-use security system for their homes or light commercial properties. With its comprehensive features and seamless integration, the LYNXR-2 is poised to meet the security needs of modern living.