Honeywell LYNXR-2 Testing the System to be conducted weekly, Entering Test Mode, Exit Test Mode

Page 45

SYSTEM FUNCTIONS

Testing the System (to be conducted weekly)

Entering Test Mode

The

TEST

key puts your system into the Test mode, which allows each protection point to be checked

for proper operation. The keypad sounds a single beep every 45 seconds as a reminder that the system is in the Test mode.

NOTE: An alarm message will not be sent to your alarm monitoring company during the following tests.

Disarm the system and close all protected windows, doors, etc. The “READY” indicator should be lit.

Enter:

Your user code

+ TEST key

WATCH. All LCD segments will light for 3 seconds.

LISTEN. The external sounder should sound for 2 seconds and then turn off. If the sounder does not sound, notify your service company.

FAULT ZONES. Open each protected door and window in turn and listen for three beeps from the keypad, followed by the zone’s Voice Descriptor, if it is programmed. Identification of each faulted protection point should appear on the display. The display will clear when the door or window is closed. Walk in front of any interior motion detectors (if used) and listen for three beeps and/or voice descriptors, if programmed. The identification of the detector should appear on the display when it is activated, and its voice descriptor will be announced (if programmed). The display will clear when no motion is detected. Note that if wireless motion detectors are used, there is a 3-minute delay between activations. This is to conserve battery life.

To test all smoke detectors, follow the manufacturer's instructions. The identification of each detector should appear on the display when each is activated.

If a problem is experienced with any protection point (no confirming sounds, no display), notify your service company.

When all protection points have been checked and are intact (closed), there should be no zone identification numbers displayed on the keypad.

Exit Test Mode

When testing is completed, exit the TEST mode by entering:

Your user code

+ OFF key.

NOTES: (1) Macros cannot be run from the Test mode.

(2)If the Test mode is inadvertently left active, it automatically turns off after 4 hours.

(3)Before turning off, the LYNXR-2SIA will flash the TEST segment on its display as a warning for the last 10 minutes of test mode.

– 45 –

Image 45
Contents LYNXR-2 Series Security System Page Table of Contents Page System Overview FeaturesLYNXR-2SIA False Alarm Prevention Features General Operation Two-Way Voice Feature Quick View of System Functions To turn Test mode off To turn Test mode onTo remotely activate X10 devices To remotely activate X10 devices 07General About the Master Keypad2ARMED 3READY Master Keypad DefinitionsLights on / Lights OFF Keys Turns LED Meanings About the Display and IndicatorsChecking System Status Securing the PremisesArming In Away Mode Arming in Stay ModeRestarting Exit Delay While System Armed Exit Delay Restart/ResetArming the System with No Delay Auto Stay FeatureTo arm with no Delay if Quick Arm is active Quick ArmingExit Delay Entry/Exit DelaysEntry Delay LYNXR-2SIA Exit/Entry Delay TimesMemory of Alarm To disarm the system and silence burglary alarmsDisarming the System Bypassing Individual Zones Bypassing Protection ZonesForced Bypass Displaying Bypassed ZonesPanic Keys / Chime Mode Chime ModePanic Keys User Functions Paging FeatureAutomatic Paging Code FormatFollow Me Reminder and System Announcements Follow Me Announcement FeatureSystem Announcements Reminder AnnouncementsTo delete Follow Me reminder telephone number To program Follow Me reminder telephone numberTo deactivate X10 devices 07 Device DescriptionsRecording a Message Message Recording/Playback/Volume ControlMessage Playback Deleting MessagesAdjusting the Volume To adjust message playback/system announcement volumeTo restore announcement sounding Function + AUX Function Defining the AUX FunctionPerforming the AUX function Hour Clock/CalendarMinute MonthYear DayScheduling User Interface Schedule number = the value that was last stored in the memoryEnd Time minute Entry Event Comment Event Identifier EntriesEntry Day Day of Week EntriesRemote Phone Control Feature Using Remote Phone Control FeatureEnter Remote Phone Control Commands To remotely disarm system To remotely arm in Away modeTo remotely Bypass zones Using the Speaker Phone Feature Speaker Phone FeatureEntering # + Remote Services Silencing a Fire Alarm General InformationCase of Fire Living Room Bedroom Fire Alarm SystemEmergency Evacuation System Functions Security CodesTo Add/Delete a User or Change a Users Code Testing the System to be conducted weekly Entering Test ModeExit Test Mode Trouble Messages Typical Trouble Condition DisplaysRoutine Care Low Battery Conditions in Wireless Sensors Changing the LYNXR-2 Series System BatteryMaintaining your system Sound Cause Display Announcement Summary of Audible NotificationAdditional Announcements Industry Canada Federal Communications Commission FCC Part 15 StatementRinger Equivalence Number Notice Federal Communications Commission FCC PartEvent of Telephone Operational Problems Servicing Information Page Notifies Insert B = Burglary, F = Fire Owners Insurance Premium Credit RequestOwners Insurance Premium Credit Request Limitations of this Alarm System Page Page Page Index No delay Pager ONE Year Limited Warranty ÊK15012yŠ

LYNXR-2 specifications

The Honeywell LYNXR-2 is an advanced wireless security system designed for residential and light commercial applications. Recognized for its user-friendly interface, the LYNXR-2 combines cutting-edge technology with essential security features, making it a popular choice among homeowners seeking peace of mind.

One of the primary characteristics of the LYNXR-2 is its sleek, modern design, which includes a large, easy-to-read touchscreen display. This intuitive interface allows users to manage their security system with minimal effort. From arming and disarming the system to viewing alerts, the touchscreen simplifies the interaction for users of all ages.

The LYNXR-2 employs Honeywell’s innovative technology, which integrates both security and home automation functionalities. This powerful system supports a wide range of wireless sensors, including door/window contacts, motion detectors, and smoke detectors. The flexibility of wireless technology means users can easily expand their security coverage without the need for complicated wiring.

Another notable feature of the LYNXR-2 is its built-in Z-Wave technology. This allows for seamless integration with smart home devices, enabling users to control lights, locks, and thermostats through the same interface. Home automation capabilities enhance security further by allowing users to program their system to perform specific actions, such as turning on lights when entering a home.

The LYNXR-2 system also offers robust communication features. It comes equipped with a cellular backup, ensuring that users remain connected to monitoring services even during power outages or if the phone line is cut. Additionally, the system supports both IP and cellular connectivity, providing flexibility in how users choose to connect their systems to monitoring services.

For those looking for added functionality, the LYNXR-2 can be easily integrated with Honeywell’s Total Connect Remote Services. This allows users to monitor and control their security system remotely through a smartphone or tablet, providing real-time notifications and updates on system status.

In summary, the Honeywell LYNXR-2 stands out for its combination of user-friendly features, advanced technologies, and extensive security and automation capabilities. It is an ideal solution for individuals seeking a reliable, scalable, and easy-to-use security system for their homes or light commercial properties. With its comprehensive features and seamless integration, the LYNXR-2 is poised to meet the security needs of modern living.